DS200RTBAG3AHC | GE Relay Terminal Card 0 to 60 oC



Introduction:
The DS200RTBAG3AHC is a GE relay terminal card for EX2000 excitation systems, featuring ten relays and 52 terminal points for mission-critical turbine control.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
When a turbine control cabinet needs dependable relay interfacing for critical I/O, the GE DS200RTBAG3AHC relay terminal card delivers a field-proven solution. As part of the EX2000 excitation system, this board provides ten relays and 52 terminal points, supporting both direct pilot relay drive and remote user control. Its rugged design is built for demanding environments, making it a reliable choice for oil and gas operations where uptime is essential.
What makes this relay relay terminal card suitable for harsh conditions?
this relay operates within a temperature range of 0 to 60 oC, ensuring stable performance in challenging industrial settings. Manufactured by General Electric in the United States of America (USA), this card is engineered for reliability in mission-critical applications. The board features normal PCB coating, which helps protect against environmental factors commonly found in oil and gas facilities.

Key features and technical specifications
- Relay count: Ten relays driven directly from pilot relays or remotely by the user.
- Terminal points: 52 I/O points, including dedicated contacts for relay K20 Form C.
- Connectors: Two stab connectors, CPH (positive) and CPN (negative), for pluggable circuit control power.
- Relay configurations: K20 to K26 are DPDT with 115 V ac coils and 10 A contacts; K27 to K29 are 4PDT with 115 V ac coils and 1 A contacts.
- Operating temperature: 0 to 60 oC.
- Series: EX2000 excitation system.
- Functional acronym: RTBA.
- Revision history: Three-fold (functional revision A, functional revision H, artwork revision C).
Each specification is traceable to GE documentation, ensuring you receive a component that meets the original design intent. The board's voltage suppression and regulation strategy incorporates capacitors, resistors, and diodes for stable operation.
Applications and use cases
This relay terminal card is designed for integration into drive cabinets within EX2000 excitation systems. It is commonly used in wind, steam, and gas turbine control assemblies, where precise relay control is essential for safe and efficient operation. In oil and gas applications, this relay provides the interface needed for critical shutdown and control signals, helping to maintain process integrity. Its robust construction and wide temperature range make it suitable for installation in remote or harsh environments where reliability is paramount.

Installation and setup guidance
Proper installation begins with a complete power-down procedure. First, stop the motor using the control panel and follow the standard shutdown sequence for the drive. Next, locate the power supply providing 3-phase current and remove the fuses to ensure all power is disconnected. The board contains high energy and poses a safety risk if touched while powered. Always verify isolation before handling the card. The two stab connectors, CPH and CPN, provide pluggable circuit control power; ensure they are correctly seated and that polarity is observed. For detailed wiring diagrams and terminal assignments, refer to the GEI-100167 instruction manual.
Maintenance and reliability
Regular inspection of this relay helps maintain reliable operation. Check for signs of wear on relay contacts and terminal points, and verify that connectors are secure. Because the board operates in demanding environments, periodic cleaning of the cabinet and ensuring proper ventilation can extend service life. The normal PCB coating provides an additional layer of protection against contaminants. Following a preventive maintenance schedule reduces the risk of unplanned downtime and supports the long-term reliability you can depend on.
Compatibility and integration
this relay is part of the EX2000 excitation system and is designed to interface with Mark V turbine control assemblies. It connects to other system boards via terminal points and stab connectors. When integrating this card into existing systems, verify compatibility with your specific drive configuration. For applications requiring fieldbus protocols, note that wiring into such networks may require an external gateway or connection module; consult PetroPartsOnline to confirm cables and gateways for your application.
Frequently asked questions
What is this relay circuit breaker panel replacement used for?
The GE this relay is a relay terminal card used in EX2000 excitation systems for turbine control. It provides relay interfacing and I/O connections for critical signals.
How many relays and terminal points does this relay have?
this relay features ten relays and 52 terminal points, offering extensive I/O capability for industrial control applications.
What are the operating temperature limits of this relay?
The GE this relay operates within a temperature range of 0 to 60 oC, suitable for many industrial environments.
What is the difference between the CPH and CPN connectors on this relay?
CPH is designated for the positive side of pluggable circuit control power, while CPN is for the negative side. Both are stab connectors on the GE this relay.
Where can I find more information about this relay?
Refer to the GEI-100167 instruction manual for detailed specifications and wiring. For availability and application guidance, contact PetroPartsOnline.
Contact PetroPartsOnline for parts suited to your application's requirements.
Frequently Asked Questions
What is the DS200RTBAG3AHC circuit breaker panel replacement used for?
The GE DS200RTBAG3AHC is a relay terminal card used in EX2000 excitation systems for turbine control. It provides relay interfacing and I/O connections for critical signals.
How many relays and terminal points does the DS200RTBAG3AHC have?
The DS200RTBAG3AHC features ten relays and 52 terminal points, offering extensive I/O capability for industrial control applications.
What are the operating temperature limits of the DS200RTBAG3AHC?
The GE DS200RTBAG3AHC operates within a temperature range of 0 to 60 oC, suitable for many industrial environments.
What is the difference between the CPH and CPN connectors on the DS200RTBAG3AHC?
CPH is designated for the positive side of pluggable circuit control power, while CPN is for the negative side. Both are stab connectors on the GE DS200RTBAG3AHC.
Where can I find more information about the DS200RTBAG3AHC?
Refer to the GEI-100167 instruction manual for detailed specifications and wiring. For availability and application guidance, contact PetroPartsOnline.