Bently Nevada 200150, 200155 and 200157 Accelerometers: Specs and Compatibility

TL;DR: The Bently Nevada 200150, 200155 and 200157 are three versions of one general-purpose, case-mounted piezoelectric accelerometer family, documented in datasheet 164986 Rev. Y and designed for Trendmaster ProTIM systems. All three share a hermetically sealed 316L stainless steel case, a top-mounted 5-pin 1/2-20 connector and 100 mV/g sensitivity at 80 Hz. They are not interchangeable. The 200150 is the ±25 g, 10–1,000 Hz general-purpose unit that also works with Trendmaster 2000 and the 1900/25 and 1900/27 monitors. The 200155 is a ±20 g, 2–10,000 Hz low-frequency sensor for fin-fan and slow-shaft applications. The 200157 is a ±25 g, 10–10,000 Hz unit with acceleration enveloping for rolling-element bearings and certain cavitation effects. The brief's 200150 figures are correct. The two details it misses are that the family does not share one measurement range or bandwidth, and that the 200155 and 200157 must not be substituted for a 200150 on 1900 monitors.
Bently Nevada's 20015x family sits at the practical end of vibration monitoring: permanently mounted sensors for machines that matter but do not justify a full 3500 protection rack. The datasheet calls them "general purpose, wide frequency, case-mounted seismic transducers designed for use with Trendmaster ProTIMs", which is a precise description of both their strength and their limit. They measure casing vibration, not shaft vibration, and every reading depends on how well rotor vibration reaches the bearing housing and how well the sensor is mounted.
This article compares the three models against the current datasheet rather than against catalogue summaries. Two numbers in circulation are wrong or incomplete: the 200155 is not a ±25 g sensor, and the family does not share a single frequency range. Both matter when you specify a replacement.
What are the Bently Nevada 200150, 200155 and 200157?
They are single-axis piezoelectric accelerometers with integrated electronics. Inside each sensor, a ceramic shear sensing element generates a charge when the case is subjected to vibration. Electronics in the housing convert that charge into a differential voltage proportional to acceleration along the sensitive axis. The output is acceleration, not velocity. Any conversion to velocity happens downstream in a Transducer Interface Module (TIM) or monitor, which is why the channel type matters as much as the sensor model.
The datasheet lists three application variants. The Bently Nevada 200150-01-05 general-purpose accelerometer is the standard acceleration-to-velocity channel type (-01) for general applications. The 200155-01-05 low-frequency Trendmaster Pro sensor is the -05 type for fin-fan coolers and slow rotating shafts. The 200157-01-05 enveloping accelerometer is the -06 type, intended for roller-element bearing defects and certain types of cavitation.
All three are built the same way: 316L stainless steel housing, hermetic sealing, ceramic shear sensing element, 3/8-24 female mounting thread in the base, and a top-mounted 5-pin connector that lets you remove the cable without disturbing the sensor. The differences are in the sensing element, the internal signal conditioning and the channel type they are designed to feed.
How do the 200150, 200155 and 200157 differ?
| Specification | 200150 | 200155 | 200157 |
|---|---|---|---|
| Datasheet description | General Purpose Trendmaster 2000 or Trendmaster Pro Accelerometer | Low Frequency Trendmaster Pro Accelerometer | Enveloping Trendmaster Pro Accelerometer |
| Measurement range | ±245 m/s² (±25 g) | ±196 m/s² (±20 g) | ±245 m/s² (±25 g) |
| Frequency range, referenced to 80 Hz (±10%) | 10–1,000 Hz (600–60,000 cpm) | 2.0–10,000 Hz (90–600,000 cpm) | 10–10,000 Hz (600–600,000 cpm) |
| ProTIM channel type | Standard acceleration-to-velocity (-01) | Low frequency acceleration-to-velocity (-05) | Standard acceleration-to-velocity with acceleration enveloping (-06) |
| Typical application | General machine casing vibration | Fin-fan coolers, slow rotating shafts, frequencies below 10 Hz | Roller-element bearings, certain cavitation effects |
| Settling time, within 5% of bias | ≤300 ms | ≤2,000 ms | ≤300 ms |
| Maximum cable length | 25 m (82 ft) | 15.24 m (50 ft) | 25 m (82 ft) |
The 200155 is the outlier. Its ±20 g range is lower than the other two, its low-frequency limit extends to 2 Hz, and its settling time is six to seven times longer. That settling time is why Bently Nevada restricts it to low-frequency acceleration-to-velocity channel types on a ProTIM, DSM or System 1 system. It is not a general drop-in sensor.
The 200157 shares the 200150's ±25 g range but extends the upper frequency limit to 10 kHz and adds acceleration enveloping. Enveloping is a demodulation technique that lifts repetitive bearing impact signals out of the overall vibration spectrum, which is why the 200157 is reserved for rolling-element bearing diagnostics rather than general casing trend monitoring.
What does 100 mV/g mean on these sensors?
Sensitivity is 10.2 mV/(m/s²), or 100 mV/g, at 80 Hz with a tolerance of ±12%. In practical terms, a 1 g acceleration produces about 100 mV of differential output. The sensor is powered by 4.7–5.5 Vdc and draws less than 800 µA quiescent current. With no vibration, the output sits at a bias of +2.5 ±0.23 Vdc; acceleration produces a signal centred on that bias, with SIG+ positive with respect to SIG− for acceleration from the base toward the connector.
That output is differential and AC-coupled in the sense that it rides on the bias voltage. It is not a 4–20 mA loop signal and it is not a velocity signal. When the accelerometer feeds a 200100 Dual Acceleration-to-Velocity flexiTIM, an 89130-01 Acceleration-to-Velocity TIM, or a 1900/25 or 1900/27 monitor, the module integrates the acceleration signal into velocity and applies its own filtering, alarming and buffered outputs.
The 1900/25 is a useful example of how much signal processing sits downstream. It is a single-channel, stand-alone vibration monitor with a built-in TIM. It accepts a 100 mV/g accelerometer, conditions the signal into peak velocity, and provides a local display plus alarm relay contacts. Its input is limited to 20 g peak, and its frequency response has a −3 dB high-pass corner at 8 Hz and a low-pass corner above 4 kHz. The 1900/27 adds a 4–20 mA interface for plants that need one. Neither monitor changes the sensor's own acceleration output; they define what the rest of the loop can do with it.
Which monitors and TIMs are officially compatible?
The datasheet is specific about the 200150. It operates with the Trendmaster 2000 system and interfaces with the 200100 Dual Acceleration-to-Velocity flexiTIM Module, the 89130-01 Acceleration-to-Velocity TIM, and the 1900/25 and 1900/27 monitors. Those are direct statements in the compatibility paragraph, not inferences from the model family.
For the 200155 and 200157, the datasheet lists only Trendmaster ProTIM channel types: -05 for the 200155 and -06 for the 200157. It also carries an explicit warning: using the 200155 and 200157 with 1900 monitors, or with TIMs other than those listed, may cause machine monitoring to fail or produce inaccurate data. A 200155 or 200157 is therefore not a substitute for a 200150 on a 1900/25 or 1900/27, even though all three sensors look identical and share the same connector.
There is a second compatibility layer inside the ProTIM. The acceleration-to-velocity circuitry in the 200200 and 200250 ProTIMs attenuates frequencies above 1 kHz. The datasheet states plainly that you cannot obtain higher frequency data with the 200155 or 200157 through those modules. The sensor may have a 10 kHz upper limit, but the channel type and module determine what the system actually delivers. Always check the ProTIM datasheet for the configured channel's frequency response rather than reading the sensor bandwidth as a system specification.
Is the 200150 really a 10–1,000 Hz sensor?
Yes. Datasheet 164986 Rev. Y gives the 200150 a frequency range of 10 to 1,000 Hz, or 600 to 60,000 cpm, referenced to 80 Hz with a ±10% tolerance. That is the sensor's specified flat range, not a resonant limit; the mounted resonant frequency is above 20 kHz for the family. Some catalogue entries quote 10 kHz for the 200150. That figure belongs to the 200157, not the 200150, and it should not be used for spare-part matching or for setting filter ranges.
The ±10% qualifier matters as much as the endpoints. Bently Nevada references the frequency range to 80 Hz, which is the calibration point for sensitivity as well. Outside the stated band, the response rolls off; the sensor does not stop working, but the amplitude is no longer within the specified tolerance. For general casing trend monitoring on a 200150, the practical measurement band is therefore 10 Hz to 1 kHz, not the full 20 kHz resonance.
Can you substitute a 200155 or 200157 for a 200150?
No, not without checking the channel type and the monitor. The datasheet warns that using the 200155 or 200157 in place of the 200150 may result in faulty readings. The reason is not mechanical compatibility; all three share the same housing, thread and connector. The reason is signal processing. A -01 channel expects a standard acceleration-to-velocity sensor. A -05 channel expects the low-frequency response and long settling time of the 200155. A -06 channel expects the enveloping signal of the 200157. Feeding the wrong sensor into a channel type changes the data, and in a protection path that is a functional problem, not a convenience issue.
The same logic applies in reverse. If an application genuinely needs content below 10 Hz, a 200150 will not provide it within tolerance; the 200155 is the correct choice. If the issue is a rolling-element bearing defect that is buried in the overall spectrum, the 200157's enveloping channel is the correct choice. Buying the general-purpose model because it is the most common one is how useful diagnostic data gets lost.
How should the sensor be mounted and cabled?
The mounting interface is a 3/8-24 female thread in the base of the housing, with a recommended torque of 2.7 to 6.8 N·m (2 to 5 ft·lbf). Bently Nevada offers a long list of mounting studs, including 3/8-24 to 1/4 NPT, 1/2 NPT, M8, M16 and UNC adapters, plus adhesive mount frames and a magnetic mount base. Adhesive and magnetic mounts attenuate high-frequency signals, so they are acceptable for general trend monitoring but a poor choice when the measurement depends on high-frequency bearing or gear content.
The top connector is a 5-pin 1/2-20 interface. The matching cables are the 200151 interface cable with connectors on both ends and the 200152 cable with a connector on the accelerometer end only. Cable construction is four-conductor 22 AWG with a braided shield and drain wire, a PVC outer jacket and nickel-plated coupling nuts. The connectors provide an IP67 seal, and Bently Nevada specifies DC4 electrical insulating compound in the connectors for additional protection against moisture during thermal shock. That is the "DC4" detail often repeated in summaries: it is a cable-connector feature, not a separate sensor fill.
Cable length has hard limits. The general maximum is 25 m (82 ft), but the 200155 is limited to 15.24 m (50 ft). Custom products may be able to supply longer lengths for the 200150 and 200157, but that is a factory question, not a field splice. The minimum bend radius is 63.5 mm for the 200151 and 73.7 mm for the 200152, which matters when the cable leaves a conduit or turns into a junction box.
What are the environmental and hazardous-area limits?
The sensor is rated for −40 °C to +105 °C, 100% relative humidity condensing and non-submerged, and an axial shock limit of 5,000 g peak. Electrical isolation is 600 Vrms. The hermetic seal is specified at a maximum leak rate of 5 × 10⁻⁸ atm·cc/s. The housing is 316L stainless steel, 17.5 mm across the hex and 45.7 mm high, with a typical weight of 58 g.
Hazardous-area approvals are separate from the general environmental rating. The family carries cNRTLus and ATEX/IECEx approvals, including Ex ia IIC T4 Ga for Zone 0/1 and Ex na IIC T4 Gc for Zone 2, with entity parameters of Ui = 28 V, Ii = 120 mA and Pi = 1 W. The approval temperature is T4 at an ambient of −40 °C to 80 °C, which is lower than the sensor's 105 °C mechanical limit. Bently Nevada also states that the accelerometers can be installed in a Class I, Zone 0 application without a barrier when used with the wSIM. If the installation is in a classified area, the approval drawing and entity parameters govern, not the generic sensor datasheet headline.
Which part number should you order as a spare?
The ordering code is 200150-AA-BB, 200155-AA-BB or 200157-AA-BB. The first two digits after the model select the mounting stud option; the final two digits select approvals, and the datasheet lists 05 as the multiple-approval option covering CSA, ATEX and IECEx. The sensor itself is unchanged by the mounting option, but the wrong stud means the spare will not fit the machine without an adapter.
For a like-for-like replacement, record four things from the existing installation before ordering: the full model and suffix, the channel type it feeds, the cable part number and length, and the mounting stud or adapter. A 200150-01-05 with adhesive mount frames is not the same spare as a 200150-07-05 with a 3/8 NPT stud, even though both are 200150 sensors. The catalogue lists several variants, including the 200157-07-05 with a 3/8 NPT stud, so the suffix is worth checking before you assume a model number is enough.
Cables are part of the spare strategy, not an accessory. The 200151 armored interface cable is available in 2 m, 4 m and 6 m lengths with unarmored or armored jacket options, while the 200152 interface cable covers 4 m, 15 m and 25 m runs. Cables are part of the same measurement loop, and a sensor with the wrong connector or run length is a downtime item waiting to happen.
What do these sensors mean for balance-of-plant monitoring?
Trendmaster Pro is Bently Nevada's Tier 2 monitoring architecture: permanently mounted sensors on a single-cable sensor bus, feeding waveform and spectrum data to System 1. It is aimed at machinery that is important enough to monitor continuously but not critical enough for a 3500 protection rack. The 20015x accelerometers are the casing-vibration element in that architecture. Their value is that one sensor family, one connector and one cable type can cover a large population of motors, fans, pumps and small turbines without a bespoke installation for each machine.
The 200150 is the standard choice for that population. It is not the highest-bandwidth or the most sensitive sensor in the Bently Nevada range, and it is not intended to be. It is the general-purpose variant that matches the -01 acceleration-to-velocity channel, and that is what makes it cost-effective: the engineering effort goes into the channel configuration and the mounting, not into a special sensor for every asset. The 200155 and 200157 exist because some assets fall outside that general case, particularly slow shafts and rolling-element bearings.
For teams that also maintain 3500 racks, the same casing-vibration logic connects to the reciprocating and rod-position side of the portfolio. The 3500/77M cylinder pressure monitor handles reciprocating compressor cylinder pressure, and the 3500/72M rod position monitor handles rod drop and rod position. They are different measurements, but the spares question is the same: model, suffix, channel type and mounting hardware.
Frequently asked questions
Are the Bently Nevada 200150, 200155 and 200157 all real models?
Yes. All three appear in datasheet 164986 Rev. Y, with separate ordering codes and separate application descriptions. The 200150 is the general-purpose model, the 200155 is the low-frequency model and the 200157 is the enveloping model.
What is the difference between the 200150 and the 200157?
Both have a ±245 m/s² (±25 g) measurement range. The 200150 covers 10–1,000 Hz and feeds a standard acceleration-to-velocity channel. The 200157 covers 10–10,000 Hz and feeds a standard acceleration-to-velocity channel with acceleration enveloping, which is used for roller-element bearing diagnostics and certain cavitation effects.
Is the 200155 a ±25 g sensor?
No. The 200155 has a measurement range of ±196 m/s² (±20 g), not ±25 g. Its distinguishing feature is the 2.0–10,000 Hz frequency range and a settling time of up to 2,000 ms, which is why it is limited to low-frequency channel types.
Does the 200150 work with the 1900/25 and 1900/27 monitors?
Yes. The datasheet lists the 1900/25 and 1900/27 monitors among the interfaces for the 200150. Both monitors accept a 100 mV/g accelerometer input and are limited to 20 g peak, so the monitor, not the sensor, sets the maximum measurable acceleration in that loop.
Can I use a 200157 with a 1900 monitor?
No. The datasheet warns that using the 200155 and 200157 with 1900 monitors, or with TIMs other than those listed, may cause machine monitoring to fail or produce inaccurate data. Use the 200150 for 1900/25 and 1900/27 applications.
What is the top connector on the 20015x?
A 5-pin 1/2-20 connector mounted on top of the housing. The matching cables use nickel-plated coupling nuts and an IP67 seal, and Bently Nevada specifies DC4 electrical insulating compound in the cable connectors for additional moisture protection during thermal shock.
What is the maximum cable length?
25 m (82 ft) for the 200150 and 200157. The 200155 is limited to 15.24 m (50 ft). Custom lengths may be available from the factory for the 200150 and 200157, but the 200155 limit is fixed by the datasheet.
Is the 20015x a velocity sensor?
No. It is a piezoelectric accelerometer with a differential voltage output proportional to acceleration. Velocity is derived downstream by the TIM or monitor, such as the 200100 flexiTIM, the 89130-01 TIM, or the 1900/25 and 1900/27 monitors.
Sources
Primary — Baker Hughes / Bently Nevada documentation
- 200150, 200155 and 200157 Accelerometers Datasheet, document 164986 Rev. Y
- Baker Hughes, Bently Nevada velocity sensors and accelerometers
- Baker Hughes, Bently Nevada online condition monitoring systems
Reference — monitor documentation