Introduction:
Flexem F5-MD1616R is a 16-point bipolar I/O module with 24 VDC input and transistor output, built for demanding oil and gas control panels.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Flexem F5-MD1616R is a Compatibility Compatible for industrial control and automation applications.
What the Flexem F5-MD1616R Delivers in Oil and Gas Panels
The Flexem this unit is a 16-point bipolar input and transistor output module rated for 24 VDC operation. It combines 16 bipolar input points with 16 transistor output points, making it a compact interface for field devices in mission-critical control cabinets.
Each input point accepts a rated 24 VDC and an input range of 0~28.8V DC. The module draws a rated current of 7mA per point and handles a voltage peak value of 30V. Input state 1 is defined as >15V (15~28.8V), while state 0 is 2.5mA in state 1 and <1.0mA in state 0. Optocoupler isolation separates field wiring from internal logic, and the input impedance is 3.3KΩ.
Filter time defaults to 1ms, with 16 equally divided levels selectable from unfiltered to 100ms. This lets engineers tune response for noisy or slow-changing signals. The module is compatible with 2/3 wire sensors and accepts source/sinking input types. Maximum cable length is 100m for shielded cable and 50m for unshielded cable. Overvoltage protection clamps at 30V maximum, limited to 1 hour per day frequency.

Key Specifications for Field Integration
- Input points: 16 bipolar points rated 24 VDC
- Input range: 0~28.8V DC with 30V peak
- Input current: 7mA rated, 9mA peak
- Isolation: Optocoupler between field and logic
- Input impedance: 3.3KΩ
- Filter time: 1ms default, selectable to 100ms
- Output voltage: 19.2~28.8VDC, rated 24 VDC
- Output current: 0.5A rated, 0.5A per group
- Output voltage drop: Maximum 1VDC
- Leakage current: <5μA when turned off
- Switching times: 34μs start, 250μs turn-off maximum
- Output frequency: 1KHz maximum
- Short-circuit protection: 1.3A peak, self-recovery per 10ms
- Clamping voltage: 39VDC maximum, ±1V
- Output isolation: 500V AC between output and internal logic
- Output cable: Unshielded, 50m maximum
How Does this unit Handle Harsh Conditions?
Oil and gas sites expose control hardware to vibration, temperature swings, and electrical noise. This unit addresses these conditions through optocoupler isolation on inputs and 500V AC isolation between outputs and internal logic. The selectable input filter helps reject contact bounce and induced noise on long field runs. Overvoltage protection at 30V maximum, limited to 1 hour per day frequency, guards input circuits against transient spikes. Output short-circuit protection with self-recovery per 10ms reduces downtime after wiring faults. These features make the module a rugged choice for demanding environments.

Comparison with Similar I/O Modules
When specifying a 24 VDC I/O module, engineers often compare bipolar input modules, relay output modules, and transistor output modules. This unit combines bipolar inputs with transistor outputs in one unit. Unlike relay outputs, its transistor outputs switch faster and include short-circuit protection. Unlike unipolar input modules, its bipolar inputs accept both source and sinking field devices. The table below summarizes typical differences; verify all values against the official datasheet.
- Input type: Bipolar (this module) vs. unipolar (many alternatives)
- Output type: Transistor with short-circuit protection vs. relay or unprotected transistor
- Isolation: Optocoupler inputs and 500V AC output isolation vs. varying isolation schemes
- Filter: Selectable 1ms to 100ms vs. fixed filter on simpler modules
- Sensor compatibility: 2/3 wire sensors vs. 2-wire only on basic modules
Installation and Wiring Guidance
Mount the module in a control cabinet that meets the panel builder's requirements. Use shielded cable for input runs up to 100m and unshielded cable up to 50m. For outputs, use unshielded cable up to 50m. Keep input and output wiring separated to reduce cross-talk. Because the module accepts source/sinking input types, confirm each field device's wiring configuration before termination. For 2/3 wire sensors, follow the sensor manufacturer's wiring diagram. Do not exceed the rated voltage range of 19.2~28.8VDC on outputs. If the application requires network integration, note that this unit provides discrete I/O only; connecting to a fieldbus may require an external gateway or communication module. Confirm cable and gateway compatibility with PetroPartsOnline before ordering.
Maintenance and Reliability Practices
Inspect terminal connections periodically for tightness and corrosion. Verify that input filter settings still match the process response time. Check output loads against the 0.5A per group rating to avoid nuisance trips. Because the module includes short-circuit protection with self-recovery, intermittent faults may clear without operator action; log such events to identify root causes. Keep spare modules on hand for mission-critical loops. Reliability you can depend on starts with proper panel design and routine inspection.
Frequently Asked Questions
What input voltage does the Flexem this unit accept?
The Flexem this unit accepts a rated 24 VDC input with an input range of 0~28.8V DC and a voltage peak value of 30V.
Can this unit drive incandescent lamps?
Yes, the Flexem this unit supports a maximum incandescent lamp power of 2.4W per output point.
What is the maximum output frequency of this unit?
The Flexem this unit has a maximum output frequency of 1KHz with start time maximum 34μs and turn-off time maximum 250μs.
Does this unit support 2/3 wire sensors?
Yes, the Flexem this unit is compatible with 2/3 wire sensors and accepts source/sinking input types.
How is short-circuit protection handled on this unit?
The Flexem this unit provides short-circuit protection with a peak short-circuit output current of 1.3A and self-recovery per 10ms after a short circuit or overload.
Contact PetroPartsOnline for parts suited to your application's requirements.