F5-MD0008P | Flexem 8 Point Output Digital Expansion Module




Introduction:
Flexem F5-MD0008P adds eight rugged NPN/PNP digital outputs to PLC systems, with 24VDC operation, 0.5A rating and short-circuit protection for oil and gas duty.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Flexem F5-MD0008P is a Flexem F5-MD0008P 8 Point Output Digital Expamsion Module for industrial control and automation applications.
How do you add reliable digital outputs to a PLC when cabinet space is tight and the environment is unforgiving? The Flexem F5-MD0008P answers that challenge as an 8 point output digital expansion module, rated 24VDC with a 0.5A output current per point. It is built for demanding environments where every output channel must hold up under continuous duty.
Each output group carries a 0.5A rating, and the module accepts a voltage range of 19.2~28.8VDC. Short-circuit protection is available, with self-recovery after a short circuit or overload every 10ms. Isolation between output and internal logic is rated 500V AC, which helps separate field wiring from sensitive control electronics.
What makes this module suitable for mission-critical output switching?
The module uses NPN (PNP) output type, so it can be configured for either sinking or sourcing duty depending on the system design. A maximum voltage drop of 1VDC across an output keeps the load voltage close to the supply rail. Leakage current when turned off is below 5μA, which matters when driving sensitive relay coils or indicating devices that must not pick up on residual current.
Switching speed is specified as a maximum start time of 34μs and a maximum turn-off time of 250μs. The maximum output frequency is 1KHz, so the module can handle fast cycling loads without losing timing integrity. For lamp loads, the maximum power of an incandescent lamp is 2.4W. Derating is not required, which simplifies cabinet thermal planning.
Protection extends to peak short-circuit output current of 1.3A and a clamping voltage maximum of 39VDC, ±1V. These rugged ratings support dependable operation in oil and gas panels where field faults are a fact of life.

Key technical specifications
- Output points: 8 point
- Output type: NPN (PNP)
- Rated voltage: 24VDC
- Voltage range: 19.2~28.8VDC
- Rated current: 0.5A
- Current per group: 0.5A output point of each group
- Voltage drop: Maximum 1VDC
- Leakage current when turned off: <5μA
- Maximum power of incandescent lamp: 2.4W
- Derating: None
- Start time: Maximum 34μs
- Turn-off time: Maximum 250μs
- Maximum output frequency: 1KHz
- Short circuit protection: Available
- Peak short-circuit output current: 1.3A
- Self-recovery after short circuit or overload: Per 10ms
- Clamping voltage: Maximum 39VDC, ±1V
- Isolation: 500V AC between output and internal logic
- Type of electrical channel: Unshielded
- Cable length unshielded: 50m
- Wiring structure: Removable terminal block
- Dimension: Dimension A
How does this module integrate with existing PLC systems?
The removable terminal block simplifies field wiring and allows pre-terminated harnesses to be swapped without disturbing the module. Unshielded cable runs up to 50m are supported, which covers most field device runs in process areas. Because the electrical channels are unshielded, routing away from high-energy conductors is good practice.
Isolation of 500V AC between output and internal logic protects the control side from transients coupled in through field cabling. This is a key consideration in oil and gas installations where long cable runs and inductive loads are common. The module is a digital expansion unit, so it is intended to extend the output capacity of a compatible PLC host rather than operate standalone.

Where is this output module used in oil and gas operations?
Typical applications include driving solenoid valves, relay coils, indicator lamps and other discrete actuators in wellhead panels, pipeline monitoring skids and compressor stations. The 0.5A per point rating suits many pilot devices and small solenoids directly. For loads above that rating, an interposing relay is the usual approach.
The short-circuit protection and self-recovery feature help reduce downtime after field wiring faults. Instead of a hard failure, the module recovers after a short circuit or overload every 10ms once the fault is cleared. That behavior supports reliability you can depend on in unattended remote sites.
Installation and maintenance guidance
Mount the module in a cabinet that respects the 19.2~28.8VDC supply range and provides adequate ventilation. Use the removable terminal block to land field wiring, and keep unshielded runs within the 50m limit. Verify that the host PLC recognizes the expansion module before energizing field loads.
Periodically inspect terminals for tightness and check for signs of overheating at load connections. Because derating is not required, thermal margin is available, but cabinet ambient temperature should still be monitored. Confirm that the 24VDC supply remains within the rated voltage range under all load conditions.
For parts suited to your application's requirements, contact PetroPartsOnline. Please verify current lifecycle status and availability with PetroPartsOnline before ordering.
Frequently Asked Questions
What is the output current rating of the Flexem F5-MD0008P?
The Flexem F5-MD0008P is rated at 0.5A per output point, with 0.5A output point of each group. This suits many solenoid valves and indicating devices directly.
Does the F5-MD0008P support both NPN and PNP output configurations?
Yes, the Flexem F5-MD0008P lists output type as NPN (PNP), so it can be applied in either sinking or sourcing arrangements depending on system design.
What is the maximum output frequency of the Flexem F5-MD0008P?
The Flexem F5-MD0008P has a maximum output frequency of 1KHz, with a maximum start time of 34μs and turn-off time of 250μs.
How does the F5-MD0008P handle short circuits?
The Flexem F5-MD0008P provides short-circuit protection with a peak short-circuit output current of 1.3A. It self-recovers after a short circuit or overload per 10ms once the fault is removed.
What is the isolation rating between output and internal logic on the F5-MD0008P?
The Flexem F5-MD0008P is rated for 500V AC isolation between output and internal logic, helping protect control electronics from field transients.