Allen-Bradley 1746-OV8 SLC 500 Output Module 24VDC


Introduction:
The 1746-OV8 is an SLC 500 discrete output module from Allen-Bradley. It features 8 sinking 24 VDC outputs with 1A per point and Class I Division 2 hazardous area approval.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1746-OV8 is a discrete output module. It belongs to the SLC 500 product family of programmable controllers. This module features eight (8) sinking output channels that operate at a voltage range of 10-50 Volts DC.
The module has a single group of outputs. Furthermore, it occupies a single slot in the SLC 500 chassis. Therefore, it can be installed in local, extension, or distributed I/O racks.
General Specifications
The 1746-OV8 offers robust output capabilities for SLC 500 systems.
Manufacturer: Rockwell Automation.
Brand: Allen-Bradley.
Series: SLC 500.
Part Number/Catalog No.: 1746-OV8.
Module Type: 24VDC output module.
Number of Outputs: 8.
Number of Groups: 1.
Voltage Range: 10-50 Volts DC (sinking).
Applications: High current general use.
Current Ratings
The 1746-OV8 delivers substantial current per output and per module.
At 30°C (86°F):
Continuous Output Current per Point: 1.0 Ampere.
Continuous Output Current per Module: 8.0 Amperes.
At 60°C (140°F):
Continuous Output Current per Point: 0.50 Amperes.
Continuous Output Current per Module: 4.0 Amperes.
Surge Current:
Rating per Point: 3.0 Amperes for 10 milliseconds.
Consequently, the module's current capacity derates at higher temperatures.
Signal Delay and Response
The 1746-OV8 has defined switching times when used with resistive loads.
Off-to-On Transition (ON Delay): 0.1 milliseconds.
On-to-Off Transition (OFF Delay): 1.0 millisecond.
Step Response: 60 milliseconds in, 2.5 milliseconds out.
Thus, the module responds quickly to control commands, with asymmetrical on/off delays.
Electrical Characteristics
The 1746-OV8 has specific electrical parameters for reliable operation.
Backplane Current (5 Volts): 135 milliamps (0.135 Amperes).
Backplane Current (24 Volts): 0 mA.
Maximum Off-State Leakage Current: 1 mA.
Minimum Load Current: 1 mA.
Maximum On-State Voltage Drop: 1.2V at 1A.
Maximum Thermal Dissipation: 6.9W.
Therefore, the module draws minimal power from the 24V backplane supply.
Terminal Block and Wiring
The 1746-OV8 simplifies field wiring with several features.
Terminal Blocks: Color-coded removable terminal blocks.
Wire Connection: Self-lifting pressure plates.
Wire Capacity: Up to two 14 AWG (2 mm²) wires per terminal.
Alternative Wiring: Pre-wired cable and 1492 interface module.
Hence, installation and maintenance are straightforward.
LED Indicators
The 1746-OV8 provides clear visual status indication.
Number of LEDs: 8 (one per output channel).
Function: Display I/O point status.
Consequently, operators can quickly identify which outputs are active.
Environmental Specifications
The 1746-OV8 withstands typical industrial conditions.
Operating Temperature: 0 to 60°C (+32 to +140°F).
Storage Temperature: -40 to +85°C (-40 to +185°F).
Relative Humidity: 5 to 95% (non-condensing).
Operating Shock: 30g.
Intended Environment: Clean and dry industrial environment.
Agency Certifications
The 1746-OV8 carries multiple approvals for global use.
UL / C-UL listed: Class I, Division 2, Groups A, B, C, D (hazardous locations).
CE marked: For all applicable European directives.
C-Tick marked: For Australian and New Zealand compliance.
Therefore, the module is suitable for installation in hazardous (Class I Division 2) areas.
Installation Flexibility
The 1746-OV8 offers broad installation options.
Chassis Compatibility: Single slot of any SLC 500 chassis.
Installation Locations: Local module, extension rack, or distributed I/O station.
Number of Instances: No actual limit (limited only by processor I/O capacity, memory, racks, and available slots).
Thus, users can install as many modules as needed for their application.
Key Features
The 1746-OV8 offers several advantages for discrete output applications.
High Current Capacity:
Provides 1A per point (8A per module) at 30°C. Therefore, it drives solenoids, relays, and small motors directly.
Sinking Outputs:
The module provides sinking (NPN) outputs. Consequently, it switches the load to ground.
Wide Voltage Range:
Operates from 10 to 50 VDC. Hence, it works with 12V, 24V, and 48V DC systems.
Class I Division 2 Certification:
Approved for hazardous locations (Groups A, B, C, D). For this reason, it suits petrochemical and industrial environments.
Removable Terminal Blocks:
Color-coded terminal blocks simplify wiring and module replacement. Thus, downtime during maintenance is reduced.
LED Status Indicators:
Eight LEDs show the on/off status of each output point. Consequently, troubleshooting is faster.
Self-Lifting Pressure Plates:
Accept up to two 14 AWG wires per terminal. Hence, field wiring is secure and reliable.
Fast Switching Speed:
0.1 ms ON delay and 1.0 ms OFF delay. Therefore, it suits high-speed discrete applications.
Typical Applications
The 1746-OV8 suits various discrete output control applications.
Solenoid valve control in industrial machinery.
Relay and contactor switching.
Pilot light and indicator driving.
Small motor starting and stopping.
Hazardous area (Class I Division 2) installations.
Installation Guidelines
Install the 1746-OV8 in any available slot of an SLC 500 chassis. First, ensure the chassis power supply can provide the required 135 mA at 5 VDC. Then, insert the module into the slot and secure it.
Connect field devices to the color-coded removable terminal blocks. Use self-lifting pressure plates to secure up to two 14 AWG wires per terminal. Alternatively, use a pre-wired cable and 1492 interface module.
Observe proper sinking output wiring: the module switches the load to ground (DC common). Provide an external DC power supply between 10 and 50 VDC. For 24V systems, the module performs optimally.
The continuous output current derates from 1A to 0.5A per point when operating at 60°C. Therefore, consider ambient temperature when sizing loads. The module is certified for Class I Division 2 hazardous locations.
What is in the Box
Please inspect all items upon delivery.
Allen-Bradley 1746-OV8 SLC 500 output module.
Color-coded removable terminal blocks.
Installation instruction manual.
Frequently Asked Questions (FAQ)
1. How many output channels does the 1746-OV8 have?
The 1746-OV8 provides 8 sinking output channels. All outputs share a single common group.
2. What is the output voltage range of this module?
The 1746-OV8 operates from 10 to 50 Volts DC. It is a sinking (NPN) output module.
3. What is the current rating per output at 30°C?
At 30°C (86°F), each output on the 1746-OV8 can continuously handle 1.0 Ampere. At 60°C, this derates to 0.5 Ampere.
4. What hazardous area approvals does this module hold?
The 1746-OV8 is UL and C-UL listed for Class I, Division 2, Groups A, B, C, D. Therefore, it is suitable for hazardous location installations.
5. How many 1746-OV8 modules can be installed in an SLC 500 system?
There is no actual limit on the number of 1746-OV8 modules. However, the processor's I/O capacity, memory, number of racks, and available slots will determine the practical limit.