Allen-Bradley 1746-OV32 SLC 500 Output Module 32 Channel 24VDC Sink

Introduction:

The 1746-OV32 is a high-density digital output module for Allen-Bradley SLC 500 systems. It provides 32 sinking output channels with a nominal voltage of 24VDC. This module supports a wide voltage range from 5 to 50VDC.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-OV32
Type: Digital DC Sinking Output Module
Condition: Subject to stock check
Weight: 0.35
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The 1746-OV32 belongs to the SLC 500 Series. Its product type is a Digital DC Sinking Output Module. The product classification is I/O Modules. The current price for this item is ¥2,850 RMB, and the product gross weight is 0.35 kg.

Rockwell Automation designed this module under the Allen-Bradley brand for SLC 500 PLC systems. The 1746-OV32 features 32 discrete sinking output channels organized into two groups of 16 channels each. This module supports a nominal signal voltage of 24VDC with a wide voltage range of 5-50VDC . Each channel delivers 0.5A at 30°C and 0.25A at 60°C. Therefore, this high-density module suits applications requiring many DC outputs in a single slot.


Technical Specifications

Output Channels and Configuration

The module provides 32 sinking output channels . Outputs are organized as two groups with 16 channels per group. Sinking output means the module switches the load to ground (common negative). This configuration suits standard DC loads such as solenoids, relays, and indicator lights.

Voltage Ratings

The nominal output voltage is 24 VDC . The acceptable output voltage range spans 5 to 50 VDC , offering exceptional flexibility. This wide range allows the 1746-OV32 to work with various DC power sources. Therefore, you can use this module with 12V, 24V, or 48V field devices.

Current Ratings

At 30°C , each output channel provides 0.50A of continuous current. At 60°C , each channel provides 0.25A of continuous current. The continuous current per module reaches 8A total across all channels. The surge current per channel is 1.0A for 10 ms at 30°C, repeatable every 1 second . At 60°C, the same surge current repeats every 2 seconds .

Signal Delay

During OFF to ON transition, the signal delay measures 0.1 ms . During ON to OFF transition, the delay extends to 1.0 ms . These fast response times suit applications requiring rapid output switching. For high-speed applications, consider these delays in your timing calculations.

Backplane Current and Isolation

The backplane current draw at 5 VDC is 190 mA (0.190A) . Isolation voltage from the backplane reaches 1500 VAC for 1 minute . This high isolation protects the PLC backplane from field wiring faults. Consequently, system reliability improves significantly.

Thermal Dissipation

The thermal dissipation per channel measures 0.172 Watts . Minimum total thermal dissipation is 0.95 Watts . Maximum total thermal dissipation reaches 6.45 Watts . When planning your enclosure cooling, account for these heat loads.

Electronic Protection

The 1746-OV32 does not include electronic protection . Therefore, Rockwell recommends using external electronic fusing for each output channel. This protects both the module and connected field devices from overcurrent damage.

Step Response

The step response measures 60 milliseconds in and 2.5 milliseconds out . This specification applies to the module's overall response to step changes. Consider this when using the module in closed-loop control applications.

Wiring Options

The 1746-OV32 provides two wiring methods. The default method uses a 40-pin female connector with crimp-type pins, requiring the 1746-NC3 wiring connector . The optional method uses the Allen-Bradley 1492 wiring system with 1492-CABLExx cables and 1492-IFM40xx DIN rail mountable terminal blocks. This option allows convenient external I/O mounting.


Installation Guide

Follow these steps to install your 1746-OV32 correctly.

  1. Power Down the Chassis: Disconnect power from the SLC 500 chassis completely. This prevents electrical damage during installation.

  2. Select a Slot: Choose an available slot in the SLC 500 chassis. The 1746-OV32 occupies one slot only.

  3. Insert the Module: Align the 1746-OV32 with the slot guides. Push firmly until the module seats into the backplane connector.

  4. Secure the Module: Tighten the retaining screws at the top and bottom. This secures the output module in place.

  5. Wire the Connector: Use the 40-pin female connector with crimp-type pins. Alternatively, use the 1492 wiring system for easier installation.

  6. Connect Field Devices: Wire your loads to the appropriate output channels. Each channel supports 5-50 VDC at up to 0.5A (30°C) or 0.25A (60°C).

  7. Apply External Protection: Install external electronic fuses on each output channel. The 1746-OV32 lacks internal electronic protection.

  8. Apply Power: Restore power to the SLC 500 chassis. Verify the module powers up without errors.

  9. Test Outputs: Activate each output channel individually. Confirm that each field device responds correctly.


Package List

  • 1 x 1746-OV32 Digital DC Sinking Output Module

  • 1 x 40-pin female connector (for default wiring method)

  • 1 x Crimp-type pin set

  • 2 x Module retaining screws (pre-installed)

  • 1 x Installation instruction manual

*Note: 1746-NC3 wiring connector and 1492 wiring system components are sold separately.*


Frequently Asked Questions (FAQ)

1. What is the difference between sinking and sourcing outputs?
Sinking output switches the load to ground (common negative). The 1746-OV32 uses sinking outputs, so the load connects between the positive supply and the output channel. For sourcing outputs, the module switches the positive side instead.

2. Does the 1746-OV32 have built-in fuse protection?
No, this module does not have electronic protection . Rockwell Automation recommends using external electronic fusing on each output channel to prevent overcurrent damage.

3. What is the maximum total current for all 32 channels?
The continuous current per module reaches 8A total across all channels. Additionally, each channel has individual limits: 0.5A at 30°C or 0.25A at 60°C. Stay within both limits for reliable operation.

4. What voltage range can I use with this module?
The 1746-OV32 accepts a wide voltage range from 5 to 50 VDC . This flexibility allows use with 12V, 24V, or 48V DC field devices. The nominal rating is 24VDC.

5. What wiring options are available for this module?
Two wiring methods exist. The default method uses a 40-pin female connector with the 1746-NC3 wiring connector. The optional method uses the Allen-Bradley 1492 wiring system with DIN rail mountable terminal blocks.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap