Schneider Electric RM AirSeT 36 kV: An SF6-Free Preview, Not a Launch

2026-11-09
Solar panels and wind turbines behind an open electrical control cabinet with a live monitoring display, illustrating SF6-free medium-voltage switchgear and cable condition monitoring
ExcerptSchneider showed a 36 kV RM AirSeT preview at Enlit Europe 2026, not a launch. What is verified on the SF6-free RMU, the cable partial discharge claim and the EU F-gas dates.

TL;DR: Schneider Electric showed a technology preview of an SF6-free RM AirSeT ring main unit rated for 36 kV at Enlit Europe 2026. It was a preview, not a launch: no ratings, availability date or price have been published, and the shipping RM AirSeT range still stops at 24 kV. The same announcement introduced a new generation of partial discharge monitoring for underground cables that continuously watches energised cables and locates defects to roughly ±1 metre over networks up to 2 km — not "millimetre-level", and not a named product. The regulatory backdrop is Regulation (EU) 2024/573, which bars putting new medium-voltage switchgear containing fluorinated greenhouse gases into operation from 1 January 2026 at 24 kV and below, and from 1 January 2030 above 24 kV up to 52 kV. Existing SF6 switchgear may still be maintained, repaired and extended.

Enlit Europe is where European utilities and industrial network operators go to compare hardware, and the 2026 edition put medium-voltage switchgear in an unusually tight spot: the first wave of the EU F-gas ban is now in force, the next one lands in 2030, and every vendor at the show is trying to look ready for both. Schneider Electric used its stand to preview a 36 kV version of the RM AirSeT ring main unit and to introduce a cable monitoring technology that attacks a different problem — ageing cable, not ageing switchgear.

Both items are easy to overstate in a headline. The 36 kV unit is a development step, not a catalogue product. The cable monitoring figure is about a metre, not a millimetre. This article separates what Schneider published on 9 November 2026 from what the show coverage implied, and then explains why the regulatory calendar — not the product launch calendar — is the part worth planning against.

What did Schneider Electric actually announce at Enlit Europe 2026?

The announcement came from Schneider Electric GmbH, the group's German subsidiary, and was dated 9 November 2026 — the day before the exhibition opened. The English text circulated the same day. Nothing was launched on the 9th at the venue, because the venue was not yet open: Enlit Europe 2026 ran from 10 to 12 November at the VIECON Vienna Congress & Convention Center, on the Messe Wien site in Vienna.

ItemVerified detail
EventEnlit Europe 2026
Dates10–12 November 2026
VenueVIECON Vienna Congress & Convention Center (Messe Wien), Vienna, Austria
Schneider Electric standHall A, booth A.a60
Announcement date9 November 2026, Schneider Electric GmbH release; English text published the same day
RM AirSeT 36 kV statusTechnology preview
Cable monitoring statusNew generation, delivered through Schneider service teams; no product name published
SpokespersonLaurent Bataille, Executive Vice President, Europe Operations

Three technologies were framed as previews, and one of them — RM AirSeT DC, a medium-voltage direct-current switchgear concept — sits outside the scope of this article. The other two are directly relevant to anyone who operates or specifies a medium-voltage distribution network: the 36 kV AirSeT unit, and the cable partial discharge monitoring.

The show programme confirms the emphasis. Schneider ran a stand session titled "SF6-Free Transition: Reflecting on Progress, Exploring What's Next" on the Wednesday, followed half an hour later by "Advanced Partial Discharge Monitoring". Those two topics are the pair the company wants utilities to think about together, and the pairing is not accidental: both are about extracting more service life from equipment that is already installed.

Was the RM AirSeT 36 kV launched or previewed?

Previewed. The wording in the release is explicit: it is the "next step" in the AirSeT programme, and the technology "aims to extend" the proven platform "beyond 24 kV". The word launch does not appear. Neither do rated current, short-circuit withstand, dimensions, mass, IP rating, an availability date or a price.

That matters because the current range is well defined. RM AirSeT is a secondary gas-insulated ring main unit for distribution networks, offered up to 24 kV and 630 A, with pure air for insulation and vacuum for switching. It is a catalogue product with a published catalogue, type tests and an installed base. The 36 kV unit shown in Vienna is a development prototype with a stated direction and no published specification.

There is a second distinction worth keeping straight. 36 kV is not new to the AirSeT family as a whole. It is already covered by GM AirSeT, the primary gas-insulated platform, which is listed up to 36 kV. What is new is bringing that ceiling down into the compact secondary ring main unit format — the enclosure class that sits in a plant substation or a street cabinet rather than a primary substation building. That is a harder engineering problem than the voltage number suggests, because the secondary RMU has to stay small, sealed for life and operable with the same three-position switching sequence.

So a procurement team should read the news as a signal about direction, not as a product they can specify today. If a tender arrives in 2027 asking for a 36 kV SF6-free RMU from Schneider, the honest answer is to ask for the technical data sheet, because none has been published yet.

What is inside RM AirSeT — and where was the SF6?

The cleanest way to understand SF6-free switchgear is to separate the two jobs that SF6 used to do. In an RM6, the sulphur hexafluoride inside the tank performed both insulation — keeping the live parts from flashing over to earth — and arc quenching, extinguishing the arc when the switch opened under load. One gas, one sealed compartment, two functions.

RM AirSeT splits them. Insulation is provided by pure air: ambient air that has been filtered and dried, held in a sealed stainless-steel tank at slight overpressure so that humidity and pollution cannot get back in. Switching is performed by vacuum interruption, in what Schneider calls Shunt Vacuum Interruption, working with a genuine three-position switch-disconnector for closed, disconnected and earthed positions. The vacuum bottle handles the arc; the air handles the dielectric gap; the visible disconnector handles isolation and earthing.

The "SF6-free" claim, in the strict sense Schneider uses it, therefore means there is no fluorinated gas anywhere in the primary circuit — not SF6, not a fluoroketone, not a fluoronitrile, not an HFO blend. The insulation medium has a global warming potential of zero by definition, and there is no gas to recover or destroy at end of life. That is a stronger claim than "low-GWP gas", which is why the company leans on the phrase "no F-gases, no proprietary mix, just simply pure air".

The claim has boundaries. It covers the switchgear, not the whole installation: connected cables, transformers, relays and auxiliary supplies are outside it. And it depends on the tank staying sealed, which is why the enclosure is specified IP67 and described as sealed for life with no refilling. A pure-air design that lost its dryness would not fail gracefully.

The digital layer is part of the same package. RM AirSeT carries an embedded RTU — now marketed as PowerLogic T300, and called Easergy T300 in earlier catalogues — plus wireless thermal and environmental sensors that pair by NFC and feed condition data to Schneider's asset management services. For a plant engineer, that is the part that turns a switchgear purchase into a monitoring subscription, and it is worth asking which of those functions survive an air gap between the OT network and the corporate one.

RM6, RM AirSeT 24 kV and the 36 kV preview compared

PlatformInsulationInterruptionMaximum rated voltageRated currentF-gasStatus
RM6SF6, sealed tankSF624 kV630 A and 200 A circuit breakersYesIn service since 1992; still supported
RM AirSeTPure air, sealed stainless tank, IP67Vacuum (SVI) with three-position disconnector24 kV630 ANoneCatalogue product
RM AirSeT 36 kVPure airVacuum (SVI)36 kVNot publishedNoneTechnology preview, no availability date
GM AirSeTPure air, primary GISVacuum36 kVNot covered hereNoneCatalogue product

The table makes the strategic picture clearer than the press release does. Schneider already sells an SF6-free 36 kV product, but it is a primary substation platform. The gap the preview addresses is the secondary distribution segment at 36 kV, which in practice means industrial plant substations and the 33 kV distribution networks of northern Europe, where 36 kV is a standard equipment rating.

What does Regulation (EU) 2024/573 actually require?

This is the part of the story that will still matter in five years, and it is routinely summarised as a blanket SF6 ban. It is not. Regulation (EU) 2024/573, in force since 11 March 2024, restricts the putting into operation of new electrical switchgear containing fluorinated greenhouse gases, on a voltage-dependent timetable, and it leaves the installed base largely alone.

EquipmentApplies fromSubstance threshold
Medium-voltage switchgear for primary and secondary distribution, rated voltage up to and including 24 kV1 January 2026F-gases, GWP of 1 or more
Medium-voltage switchgear for primary and secondary distribution, above 24 kV up to and including 52 kV1 January 2030F-gases, GWP of 1 or more
High-voltage switchgear above 52 kV up to and including 145 kV, short-circuit current up to 50 kA1 January 2028F-gases, GWP of 1 or more
High-voltage switchgear above 145 kV1 January 2032F-gases, GWP of 1 or more

Four details change how the timetable lands in a real project.

  • The trigger is commissioning, not purchase. The prohibition applies at the moment equipment is put into operation — handed over to the operator after functional tests — not at energisation and not at order. Delivery and commissioning dates therefore both belong in the compliance plan.
  • The obligation sits with the operator. The entity exercising actual control over the switchgear is responsible for compliance, which in an industrial plant usually means the site owner rather than the EPC contractor. Derogations exist where no compliant offer meets the specification, but they carry documentation and notification duties to the competent authority under Article 13(17).
  • Existing SF6 equipment stays legal. Maintenance, repair and extension of switchgear put into operation before the ban dates remain permitted, with a specific derogation under Article 13(15) where an SF6 extension is the only way to avoid replacing an entire board. That is the provision that keeps RM6 fleets serviceable.
  • Service gas rules tighten later. From 2035, SF6 used for servicing and maintenance must be reclaimed or recycled, and technicians handling these gases need certification with a refresher every seven years. Gas-handling capability is therefore a depreciating asset, not a permanent one.

For a 36 kV unit, the relevant date is 1 January 2030, not 2026. That single fact explains the timing of the preview better than any marketing narrative: the 24 kV segment is already closed to new F-gas equipment, and the 24–52 kV segment is the next commercial window. A vendor that wants to be specified in 2029 has to be visible in 2026.

What is the new cable partial discharge monitoring — and how accurate is it?

The second announcement addresses a different asset class. Schneider describes it as a new generation of partial discharge monitoring and localisation for underground cables, aimed at operators of ageing medium-voltage cable networks who currently face two expensive choices: wait for a fault to cause an outage, or take cables offline for testing and replace long sections, including healthy ones.

The published capability is specific, and narrower than some coverage suggested:

  • Continuous monitoring of energised cables. The cables stay in service; the technology monitors partial discharge while the network is live, rather than during an offline test.
  • Defect classification and risk assessment. It measures partial discharge, identifies the type of defect and assesses the associated risk, rather than only flagging that discharge exists.
  • Localisation to approximately ±1 metre on networks up to 2 km long. That is the figure Schneider published, in both the German and English versions.
  • Non-intrusive deployment on existing networks. It is designed to be fitted to cables already in service, not only to new-build circuits.
  • Services-led availability. It can be deployed today with Schneider Electric service teams in Europe, with global availability planned and native integration into the medium-voltage switchgear portfolio to follow.

What is not published matters just as much. There is no product name, no product line, no sensor count, no frequency band, no partial discharge sensitivity in picocoulombs, no list of supported cable types and no data platform specification. Any article that gives the technology a model number is inventing it.

Two claims in circulation should be retired. The first is "millimetre-level" accuracy: the published figure is about one metre, which is a different order of magnitude and still good enough to send a crew to the right joint. The second is "acoustic-optical" location: the release describes partial discharge measurement and localisation, and mentions neither acoustics nor optics. If a supplier claims either, ask for the data sheet.

One engineering observation is worth adding, clearly labelled as inference rather than vendor specification. Locating a defect to ±1 m on a 2 km cable implies timing resolution of roughly 10 nanoseconds, assuming a propagation velocity near 0.2 m per nanosecond in XLPE insulation. That is achievable with modern sampling electronics, and it tells you the method is time-domain rather than a rough thermal or acoustic correlation. It also means the interesting engineering is in detection sensitivity and false-alarm rejection, not in the location arithmetic.

It is also worth separating this from switchgear partial discharge monitoring, which Schneider already sells as part of its EcoCare service. That monitors discharge inside switchgear. The new announcement is about the cable network between assets — joints, terminations and insulation — which is where a large share of medium-voltage faults actually start.

Why does this matter for industrial and petrochemical plant grids?

Most coverage of Enlit treats it as a utility story, and for the 36 kV unit that is fair. But the readers of this site run plants, not distribution concessions, and the same two technologies land differently inside a fence line.

A large petrochemical or refining site typically takes power at 110 kV or 220 kV and distributes internally at 33 kV or 36 kV, stepping down to 11 kV, 6.6 kV and 400 V. That internal 36 kV network is built from the same ring main units and the same XLPE or paper-insulated cables as a municipal network, but it has two differences that matter. First, the cable routes are long, congested and buried under pipe racks, so excavation is disproportionately expensive. Second, an unplanned outage does not inconvenience households; it trips process units, and the restart cost dwarfs the cable repair.

That is precisely the economics the cable monitoring technology targets. Offline partial discharge testing requires an outage window that a continuous process plant rarely has, and it samples the cable only on the day of the test. Continuous monitoring on an energised cable converts a periodic inspection into a trend, which is the same argument that made online condition monitoring standard on critical rotating machinery — the approach described in our analysis of cylinder pressure monitoring on reciprocating compressors. The difference is that a compressor has a vibration signature you can trend every revolution, while a cable has to be listened to for discharge events that may occur once a week.

On the switchgear side, the relevance is procurement and spares rather than operations. If your site is planning a substation replacement or a capacity upgrade that will commission after 1 January 2030, the 24–52 kV band is where the F-gas restriction will bite. A 36 kV SF6-free RMU that is still in preview today is a reasonable thing to track, and a poor thing to write into a 2027 tender without a data sheet.

The commercial context is also moving. Schneider's third-quarter 2026 results showed energy management growing far faster than industrial automation, driven by data-centre and grid demand, and the same investment cycle is visible in grid-related order growth at ABB India. More grid capex means more medium-voltage equipment in the field, and more equipment in the field means more of it reaching the age where cable and switchgear condition, not nameplate rating, decides availability.

What should maintenance and procurement teams verify?

  • Ask whether a 36 kV quotation is real. As of this announcement there is no published specification, so a firm offer should be treated as a custom project until Schneider issues type-test data.
  • For 24 kV RM AirSeT, check the digital scope. Confirm which RTU variant is supplied (PowerLogic T300 is the current name), how the wireless sensors pair, what the module does when the backhaul link drops, and whether the cyber hardening documented for your OT network applies to the firmware in the box.
  • Treat the cable monitoring as a service first. Clarify which cable types and voltage classes are covered, whether joints and terminations are included, who owns the data, how alarms reach the control room, and what the false-alarm rate looks like in your cable population. There is no published sensitivity figure, so ask for field evidence rather than a brochure claim.
  • Do not budget from press coverage. Neither item has a published price. The 36 kV unit has no announced availability, and the cable monitoring is sold through service teams, which means the commercial model is likely to be recurring rather than a one-off box price.
  • Keep gas competence if you still run RM6. The installed base remains legal and serviceable, but SF6 handling requires certified technicians, recovery equipment and, from 2035, reclaimed or recycled gas. Plan the training and gas logistics before they become a bottleneck, not after.
  • Watch the low-voltage interface. A ring main unit is only as good as what hangs off it; the protection chain downstream, from moulded-case breakers to the TeSys Giga contactors that switch the load, has to be coordinated with the new relay settings.

One further practical point applies to any digital switchgear purchase. The controller is now part of the asset. If the substation automation layer runs on Modicon M580 processors or a comparable platform, confirm that the RTU's protocols, time synchronisation and firmware lifecycle fit the site standard. A switchgear that is mechanically sound but digitally orphaned becomes a maintenance liability in year eight.

Frequently asked questions

Did Schneider Electric launch a 36 kV RM AirSeT at Enlit Europe 2026?

No. It was a technology preview. Schneider's release describes the 36 kV unit as the next step in the AirSeT programme, extending the platform beyond 24 kV. No rated current, short-circuit rating, dimensions, availability date or price has been published, and the shipping RM AirSeT range remains at 24 kV and 630 A.

When exactly was the announcement made, and where was the show held?

The release was published on 9 November 2026 by Schneider Electric GmbH, one day before Enlit Europe 2026 opened. The exhibition ran from 10 to 12 November 2026 at the VIECON Vienna Congress & Convention Center on the Messe Wien site in Vienna, with Schneider in Hall A at booth A.a60.

Is RM AirSeT genuinely free of SF6 and other fluorinated gases?

Yes, for the primary circuit. RM AirSeT uses filtered, dried ambient air at slight overpressure for insulation and vacuum interruption for switching, in a sealed stainless-steel tank. There is no SF6, fluoroketone, fluoronitrile or HFO blend in the switchgear, so the insulation medium has a global warming potential of zero and there is no gas to recover at end of life.

When will the EU ban SF6 in 36 kV switchgear?

For medium-voltage equipment above 24 kV up to and including 52 kV, Regulation (EU) 2024/573 applies from 1 January 2030. The restriction bites when new equipment is put into operation, not when it is ordered, and it covers fluorinated greenhouse gases with a global warming potential of 1 or more. Existing equipment may still be maintained, repaired and extended.

Does the new cable monitoring really locate faults to the millimetre?

No. Schneider publishes approximately ±1 metre on networks up to 2 km. That is precise enough to identify the joint or termination to excavate, but it is a metre-class figure, not a millimetre-class one. The release also makes no mention of acoustic or optical location methods.

Can I buy the cable partial discharge monitoring now?

It is available through Schneider Electric service teams in Europe today, according to the release, with global availability planned. No product name, model number, sensitivity specification or price has been published, and broader native integration into the medium-voltage switchgear portfolio is described as a future step.

Do I have to replace existing SF6 switchgear before 2030?

No. The regulation targets new equipment being put into operation. Maintenance, repair and extension of existing SF6 switchgear remain permitted, including a specific derogation where an SF6 extension is the only alternative to replacing an entire board. What changes over time is the servicing regime: from 2035, SF6 used for maintenance must be reclaimed or recycled, and technicians must be certified.

Sources and verification notes

Facts in this article were checked against Schneider Electric's own publication and product pages, the exhibition organiser's schedule, and the consolidated text of Regulation (EU) 2024/573. Three corrections to the brief that prompted this article are worth stating plainly: the 36 kV RM AirSeT was a preview rather than a launch; the cable monitoring accuracy is about one metre, not millimetres, and no acoustic-optical method was announced; and the EU rules are a staged restriction on putting new equipment into operation, not a blanket SF6 ban.

Not verified and therefore not stated as fact anywhere above: a product name or model number for the cable monitoring technology, its partial discharge sensitivity, the electrical ratings of the 36 kV RM AirSeT preview, its availability date, and any price for either item.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap