25C-B062N104 | Allen-Bradley 15 kW EtherNet/IP AC Drive



Introduction:
Allen-Bradley 25C-B062N104 PowerFlex 527 drive delivers 15 kW normal duty at 200…240V AC with dual EtherNet/IP ports and integrated Safe Torque Off.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Allen-Bradley 25C-B062N104 is a AC adjustable-frequency drive — PowerFlex 527 for industrial control and automation applications.
Allen-Bradley 25C-B062N104 is a PowerFlex 527 AC adjustable-frequency drive rated 15 kW (20 HP) normal duty and 11 kW (15 HP) heavy duty at 62.1 A, with a 200…240V AC three-phase input. It is a Frame E, IP20 NEMA/Open Type unit with dual embedded EtherNet/IP ports and integrated Safe Torque Off. For oil and gas panels, this combination puts motor control, network connectivity and a certified safety function in one field-proven package built for demanding environments.
What makes this drive suitable for mission-critical pump and fan duty?
The drive is engineered around the electrical conditions that oil and gas installations actually present. Its input stage accepts 200…240V AC three-phase supply with -15 % / +10 % voltage tolerance and 47…63 Hz input frequency, so it rides through the supply variation common on remote sites. A displacement power factor of 0.98 across the entire speed range keeps the load on upstream generators and transformers predictable.
Protection is equally deliberate. Power ride-through of 100 ms and logic control ride-through of 0.5 s minimum (2 s typical) let the drive bridge short interruptions without dropping control. The DC bus trips at 405 V DC overvoltage and 190 V DC undervoltage, while overcurrent limits stand at 200 % hardware and 300 % instantaneous fault. Electronic motor overload protection is class 10 per NEC article 430, backed by UL 508C File 29572.

Key specifications at a glance
- Input voltage: 200…240V AC, 3-phase, with -15 % / +10 % tolerance.
- Input frequency: 47…63 Hz.
- Output: 0 V to rated motor voltage, 0…590 Hz programmable.
- Continuous output current: 62.1 A maximum at rated output voltage.
- Normal duty overload: 110 % for up to 60 s, 150 % for up to 3 s.
- Efficiency: 97.5 % typical.
- Operating temperature: -20…+50 °C without derating in vertical IP20 mounting; up to +60 °C derated, and up to +70 °C derated with the 25-FANx-70C control module fan kit.
- Storage temperature: -40…+70 °C for Frame E.
- Enclosure: IP20 NEMA/Open Type, panel mount, Frame E.
- Dimensions: 300.0 H × 185.0 W × 279.0 D mm; weight 12.9 kg.
Note that the published drive rating is based on a 4 kHz carrier frequency, adjustable from 2…8 kHz. The internal DC bus choke is fitted for Frame E ratings in the 200…240V AC class, which supports stable operation on weaker supplies.
How does the drive integrate with a Logix control system?
Two embedded EtherNet/IP ports connect the drive to linear, star or Device Level Ring topologies. CIP Safety allows safety data, standard control data and diagnostics to travel simultaneously over the same network. Integrated motion is available through CIP Motion commands from a Logix-based controller; a ControlLogix system requires a 1756-EN2T, 1756-EN2TR or 1756-EN3TR EtherNet/IP module, while a CompactLogix 5370 controller uses its dual embedded ports.
The embedded Safe Torque Off input is TÜV Rheinland approved up to Performance Level e (PLe), Category 3 per EN ISO 13849 and SIL CL 3 per IEC 61508, EN 61800-5-2 and EN 62061, with a response time under 12 ms. For position or velocity feedback, the 25-ENC-2 incremental encoder option board provides a 5V or 12V, 250 mA supply.
Integration note: wiring into an EtherNet/IP network may require an external gateway or connection module depending on the plant architecture. Confirm cables, gateways and network accessories with PetroPartsOnline before commissioning.

Comparison with alternative drive configurations
Buyers specifying a 15 kW class drive often weigh this model against neighbouring options in the PowerFlex 520 series. The comparison below is limited to published differences that matter in the field.
- this drive (this model): dual embedded EtherNet/IP, integrated Safe Torque Off, no integral EMC filter, no RS-485 DSI port.
- PowerFlex 523 and 525 members: the 520-series platform also includes the 523 and 525; the 527 is the family member that carries embedded EtherNet/IP and integrated safety as standard.
- EMC filtering: this catalog number has no integral EMC filter; external filters provide EN 61800-3 Category C1/C2/C3 compliance where required.
- Enclosure upgrade: IP30 / NEMA 1 / UL Type 1 protection requires the 25-JBAx option kit; the base unit is IP20 NEMA/Open Type.
- Braking: an integral brake IGBT is fitted, but dynamic braking requires an external brake resistor.
Where a project needs a different network or a filtered variant, selection guidance should follow the application's requirements rather than a generic default.
Where this drive fits in oil and gas operations
Typical duty includes variable-speed pump control, cooling tower fans and process blowers on upstream and midstream sites. The 68 dBA sound pressure level measured 1 m from the Frame E unit is worth noting where equipment sits near work areas. Altitude capability reaches 1000 m without derating and up to 4000 m with derating, which covers many remote installations. Conformal coating to IEC 60721-3-3 level 3C2 (chemical and gases only) adds protection, provided the ambient atmosphere is free of volatile or corrosive gases, vapors and dust.
For hazardous areas, the drive carries ATEX certificate TÜV 15 ATEX 7696 X and UKEX certificate TUV 21 UKEX 7033 X for Group II Category (2) GD applications with ATEX approved motors. Seismic qualification follows AC156 and the 2003 International Building Code worst-case level for the USA excluding site class F. The unit also holds Lloyd's Register Type Approval 15/80016(E1), which suits marine and offshore projects.
Installation and maintenance considerations
Frame E drives are screw mounted only; DIN-rail mounting applies to Frames A…C. The drive produces protective earthing current above 3.5 mA AC and/or 10 mA DC, so the earthing conductor must meet local regulations for high protective-earthing-current equipment. Installers should also verify harmonic current requirements with the distribution network operator, because no per-catalog THD figure is published for the series.
Maintenance is straightforward: inspect cooling fans and heatsink airflow periodically, check terminal torque at scheduled shutdowns, and keep the enclosure free of dust and corrosive vapors. For safety functions, follow the manufacturer's safety manual and inspect the STO wiring at planned intervals. These practices protect the 97.5 % typical efficiency and support reliability you can depend on over long service intervals.
Frequently Asked Questions
What input voltage does the 25C-B062N104 require?
The Allen-Bradley 25C-B062N104 accepts a 200…240V AC three-phase input with -15 % / +10 % voltage tolerance and 47…63 Hz input frequency. Single-phase input on this three-phase drive provides 35 % of the rating.
What is the operating temperature range of the 25C-B062N104?
The Allen-Bradley 25C-B062N104 operates from -20 °C ambient in vertical IP20 mounting, with +50 °C without derating. Operation up to +60 °C is derated, and up to +70 °C derated with the 25-FANx-70C control module fan kit.
Does the 25C-B062N104 include an EMC filter?
No. The Allen-Bradley 25C-B062N104 has no integral EMC filter; external filters provide EN 61800-3 Category C1/C2/C3 compliance where the installation requires it.
Which network protocols does the 25C-B062N104 support?
The Allen-Bradley 25C-B062N104 provides dual embedded EtherNet/IP ports supporting linear, star and Device Level Ring topologies, with CIP Safety for simultaneous safety and control data. It has no RS-485 DSI port.
What safety rating applies to the 25C-B062N104?
The Allen-Bradley 25C-B062N104 carries integrated Safe Torque Off approved by TÜV Rheinland up to Performance Level e (PLe), Category 3 per EN ISO 13849 and SIL CL 3 per IEC 61508, with a response time under 12 ms.
Availability and support