Long-Range Laser Positioning for Demanding Environments
The SICK DL100-23HA2101 is a phase-shift optical time-of-flight laser distance sensor from the Dx100 series. It measures up to 300 m on Diamond Grade reflective tape with typical accuracy of ± 2 mm to ± 3 mm. This makes it a dependable choice for critical positioning tasks in oil and gas operations.
Engineered for demanding environments, the DL100-23HA2101 combines a rugged aluminum die-cast housing with an integrated heating system. As a result, it operates reliably from -40 °C to +55 °C. The sensor also provides SSI communication and a fast 1 ms internal measurement rate.

Why This unit Suits Oil and Gas Applications
Oil and gas facilities often require precise, long-range measurement in extreme conditions. This unit addresses these needs through several field-proven features:
- Extended measuring range: 0.15 m to 300 m on Diamond Grade reflective tape supports long-distance positioning.
- High accuracy: Typical measurement accuracy of ± 2 mm to ± 3 mm ensures reliable position feedback.
- Fast response: Internal measurement rate of 1 ms enables real-time control in dynamic applications.
- Integrated heating: The internal heating system allows operation down to -40 °C, ideal for cold climates.
- Rugged housing: Aluminum die-cast body with PMMA optical window and IP65 protection resists dust and water jets.
- SSI interface: Synchronous Serial Interface with Gray or binary code for direct integration with controllers.
- High dynamics: Maximum tracking velocity of 15 m/s and acceleration of 15 m/s² suit automated storage and retrieval systems.
Each feature is designed to maintain reliability you can depend on in mission-critical operations.
Technical Specifications at a Glance
- Operating temperature: -40 °C ... +55 °C (with integrated heating active)
- Storage temperature: -40 °C ... +75 °C
- Supply voltage: DC 18 V ... 30 V (reverse-polarity protected)
- Power consumption: Typ. 25 W ... 35 W (heating element active)
- Measurement principle: Phase shift optical time-of-flight laser distance measurement
- Light source: Visible red laser diode, 658 nm, Class 2 (< 1 mW)
- Dimensions (W x H x D): 69.4 mm x 82.5 mm x 100.2 mm
- Weight: Approx. 1,000 g
- Electrical connection: Power: M12 4-pin male (A-coded, SPEEDCON™); SSI bus: M12 8-pin female

Installation and Integration Guidance
This unit is designed for straightforward installation in industrial settings. Its integrated LC display and menu navigation simplify configuration and diagnostics. The optical 3-axis alignment bracket compatibility allows precise alignment during setup. For power, connect the M12 4-pin male connector to a DC 18 V ... 30 V supply. The SSI bus uses an M12 8-pin female connector. Ensure the sensor is mounted securely to avoid vibration effects. When integrating into an SSI network, verify cable and gateway compatibility with PetroPartsOnline. Note that wiring into fieldbus networks may require an external gateway or connection module; confirm all components with the supplier.
Maintenance and Reliability
Regular inspection helps maintain optimal performance. Check the PMMA optical window for dust or debris and clean it gently with a soft cloth. Inspect connectors for tightness and signs of corrosion. The integrated heating system should be tested periodically in cold environments. The rugged aluminum housing and IP65 rating reduce maintenance needs in harsh conditions. By preventing downtime, This unit supports reliable, continuous operation in oil and gas facilities.
Frequently Asked Questions
What is the operating temperature range of This unit?
The SICK unit operates from -40 °C to +55 °C with the integrated heating system active.
What supply voltage does This unit require?
The sensor requires a DC supply voltage of 18 V to 30 V and is reverse-polarity protected.
How does This unit communicate with control systems?
It uses an SSI (Synchronous Serial Interface) with Gray or binary code, provided via an M12 8-pin female connector.
What is the maximum measuring range of This unit?
The sensor measures up to 300 m when used with Diamond Grade reflective tape.
Is This unit suitable for cold storage applications?
Yes, the integrated heating system allows reliable operation down to -40 °C, making it suitable for cold environments.
Contact PetroPartsOnline for parts suited to your application's requirements.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "DL100-23HA2101 | SICK 300 m SSI Laser Sensor", "mpn": "DL100-23HA2101", "sku": "DL100-23HA2101", "brand": {"@type": "Brand", "name": "SICK"}, "description": "Long-Range Laser Positioning for Demanding Environments The SICK DL100-23HA2101 is a phase-shift optical time-of-flight laser distance sensor from the Dx100 series. It measures up to 300 m on Diamond Grade reflective tape with typical accuracy of ± 2 mm to ± 3 mm. This makes it a dependable choice for critical positioning tasks in oil and gas operations. Engineered for demanding environments, the DL100-23HA2101 combines a rugged aluminum die-cast housing with an integrated heating system. As a r", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/10/1793101320-api_image__fp341c50c1.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/10/1793101328-api_image__fp0f301b45.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/10/1793101335-api_image__fp6f6661cb.jpg"]}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the operating temperature range of This unit?", "acceptedAnswer": {"@type": "Answer", "text": "The SICK unit operates from -40 °C to +55 °C with the integrated heating system active."}}, {"@type": "Question", "name": "What supply voltage does This unit require?", "acceptedAnswer": {"@type": "Answer", "text": "The sensor requires a DC supply voltage of 18 V to 30 V and is reverse-polarity protected."}}, {"@type": "Question", "name": "How does This unit communicate with control systems?", "acceptedAnswer": {"@type": "Answer", "text": "It uses an SSI (Synchronous Serial Interface) with Gray or binary code, provided via an M12 8-pin female connector."}}, {"@type": "Question", "name": "What is the maximum measuring range of This unit?", "acceptedAnswer": {"@type": "Answer", "text": "The sensor measures up to 300 m when used with Diamond Grade reflective tape."}}, {"@type": "Question", "name": "Is This unit suitable for cold storage applications?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the integrated heating system allows reliable operation down to -40 °C, making it suitable for cold environments. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}