What the GE IC670PBI001 Profibus Interface Module Does
The GE this module is a Profibus bus interface unit from the GE Fanuc Field Control series. It connects Field Control I/O modules to a host GE CPU over a Profibus network, enabling distributed I/O architecture. The module operates on a 24 VDC power supply and supports up to eight I/O modules per station.
Engineers specifying a plc module replacement for a Field Control station will find this module built for demanding environments. Its aluminum housing and DIN rail mounting suit panel, junction box, and behind-operator-station installations where space is limited.

Key Features and Technical Specifications
- Manufacturer: GE Fanuc
- Product Type: Profibus Bus Interface
- Power Supply: 24 VDC
- Voltage Range: 18-30 Volts DC
- Input Power: 7.7 watts
- Power Dissipation: 4.45 Watts
- No. of Ports: Profibus: One (1) 9-pin D-sub connector; Programmer: One (1) 9-pin D-sub connector
- Addressing: via embedded DIP switches
- Holdup Time: 10 ms, maximum
- Profibus Topology: Linear bus topology
- Transmission Speed: 9.6, 19.2, 93.75, 187.5, 500, 1500 Kbits, 3 Mbits, 6 Mbits, and 12 Mbits
- Status LEDs: PWR, RUN, OK
- Network Medium: Shielded twisted pair cable
- Ambient Operating Temperature: 0-55 degrees Celsius
- Mounting: DIN Rail / Panel mount via the Profibus Bus Interface Unit (BIU) terminal block
- No. of Supported I/O Modules: up to Eight (8) modules
- No. of Stations per Profibus Segment: 32
- Programming: via Hand-Held Programmer
- Supported Functions: I/O forcing; Diagnostic display; Program upload/download
- Reliability: 180,000 hours operation MTBF
The 24 VDC input voltage and 18-30 Volts DC range allow the module to ride through typical supply variations in oil and gas facilities. With a maximum holdup time of 10 ms, this module maintains operation during brief power interruptions. The 0-55 degrees Celsius operating temperature covers most climate-controlled and sheltered field enclosures.
How This Interface Module Compares with Other Field Control Options
When selecting a bus interface for a Field Control station, engineers often compare this module with other network interface modules in the series. The following bullet points outline the key differences based on the available data.
- Network protocol: this module supports Profibus, while other Field Control interface modules may support different protocols. Confirm the host CPU network before ordering.
- Port configuration: This model provides two 9-pin D-sub connectors: one for Profibus and one for a Hand-Held Programmer. Modules without an HHP port require alternative programming methods.
- I/O capacity: this module hosts up to eight Field Control I/O modules per station. Verify the required I/O count against this limit.
- Addressing: Node address is set via embedded DIP switches (address 00-32), a field-proven method that avoids software configuration for basic setup.
- Power requirements: The module operates on 24 VDC with an 18-30 Volts DC range and 7.7 watts input power. Compare this with the power budget of your panel.
For applications requiring a different protocol or higher I/O count, consult PetroPartsOnline for application-specific selection guidance.

Installation and Commissioning Guidance
this module mounts to a Bus Interface Unit (BIU) terminal block, which provides DIN rail or panel mounting. Wiring is simplified because the terminal block remains in place when the module is removed or replaced, eliminating reconfiguration of the control station. Connect the Profibus network using shielded twisted pair cable, and terminate the first and last nodes with resistors per linear bus topology. Set the node address using the eight DIP switches before powering the module. The replaceable slow-blow fuse on the input power line can be changed without rewiring.
Reliability and Maintenance in Oil and Gas Environments
this module is built for demanding environments, with a rugged aluminum housing and noise resistance. Its 180,000 hours MTBF reflects dependable operation in mission-critical distributed I/O systems. For maintenance, inspect the module periodically for dust buildup and secure connections. Verify that the PWR, RUN, and OK LEDs indicate normal status. Because the module supports hot replacement without rewiring, spare parts inventory can be minimized. PetroPartsOnline supplies reliable sourcing for critical operations, helping you avoid unplanned downtime.
Frequently Asked Questions
What is the power supply requirement for this module?
The GE this module requires a 24 VDC power supply with an operating voltage range of 18-30 Volts DC. Input power is 7.7 watts, and power dissipation is 4.45 Watts.
How many I/O modules can this module support?
The GE this module supports up to eight Field Control I/O modules per station. This capacity allows a compact distributed I/O architecture with a single interface module.
What is the operating temperature range of this Profibus interface module?
The GE this module operates within an ambient temperature range of 0-55 degrees Celsius. Ensure the enclosure or panel maintains this range for reliable operation.
How is the node address configured on this module?
The GE this module uses embedded DIP switches for addressing, with an eight-switch array for addresses 00-32. Set the address before applying power to the module.
What transmission speeds does this module support?
The GE this module supports Profibus transmission speeds of 9.6, 19.2, 93.75, 187.5, 500, 1500 Kbits, 3 Mbits, 6 Mbits, and 12 Mbits. Use shielded twisted pair cable as the network medium.
Contact PetroPartsOnline for parts suited to your application's requirements.