FE6370W | Flexem 7" HMI 0-50°C Wide-View Resistive



Introduction:
The Flexem FE6370W is a 7-inch wide-viewing-angle resistive-touch HMI with a 1024×600 display and DC 24V input, built for dependable panel operation in demanding plants.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Flexem FE6370W is a 7-inch wide-viewing-angle resistive-touch HMI from the FE6300 Series, rated for 0 to 50 °C operation and powered from a DC 24V supply (range DC 9 to 28 V). It combines a 1024×600 TFT LCD with a 1GHz dual-core ARM Cortex-A7 CPU, making it a practical operating terminal for maintenance and process teams that need a clear, rugged interface at the panel.
What makes this unit suited to field service?
From a maintenance engineer's viewpoint, the value of an HMI lies in how predictably it behaves and how quickly a fault can be isolated. This Flexem unit is built around a small set of well-defined interfaces and a front face sealed to IP65 when mounted flush, so washdowns and dust on the panel front are less of a concern. The rear is rated IP20, which keeps the focus on clean cabinet installation.
Because Ethernet and Bluetooth are not supported, the communication path is deliberately simple: serial ports and USB. That simplicity reduces the number of variables a technician must check when a screen stops updating. The FLink2 pluggable IIoT module slot provides an expansion route without changing the base wiring.

Key technical parameters for reliability planning
- Operating temperature: 0 to 50 °C — plan cabinet ventilation around this range.
- Supply voltage: DC 24V with an input range of DC 9 to 28 V.
- Power consumption: <10W maximum, easing load on panel power budgets.
- Power interruption tolerance: <5ms maximum, helping ride through brief supply dips.
- Power protection: Lightning and surge protection built in.
- EMC: EN61000-6-2:2019 and EN61000-6-4:2019, RoHS; surge ±1kV, EFT ±2kV, ESD contact 4kV / air 8kV.
- Display: 7" 16:9 TFT LCD, 1024×600, 24-bit color, 350 cd/m², LED backlight.
- LCD lifetime: 50,000 hours, a useful figure for backlight replacement planning.
- Touch panel: 4-wire industrial resistive touch screen.
- CPU and memory: 1GHz dual-core ARM Cortex-A7 with 256MB DDR3 + 256MB Flash.
- Built-in ports: 1×Type-C 2.0 (USB Slave) and 1×USB Type A 2.0 (USB Host).
- Serial ports: COM1 RS232/RS485/RS422; COM2 RS485; COM3 RS232.
- Enclosure: Engineering plastic, light gray.
- Panel cutout: 190×136 mm; dimensions 145×204×36.6 mm; weight ~0.476 kg.
How does the DC 24V input simplify maintenance?
Most control cabinets in oil and gas facilities already distribute DC 24V, so this unit can be fed from an existing supply without a dedicated converter. The wide DC 9 to 28 V range gives technicians margin during brownouts or when a shared supply sags under load. Combined with the <5ms power interruption tolerance, the terminal is less likely to reboot during switching transients.
For service work, the USB Type-C slave port and U-disk download path mean program updates can be made without opening the cabinet rear. The USB Type A host port accepts a standard U-disk, which is convenient for field backups. Because the unit draws <10W maximum, a faulty terminal is unlikely to overload a shared power supply, which helps isolate the fault faster.

Installation and environmental considerations
Flush mounting uses a 190×136 mm cutout, and the front reaches IP65 only when properly seated in the panel. Maintenance teams should verify gasket compression during any panel rework, because a distorted bezel is a common cause of moisture ingress. The rear IP20 rating means the cabinet interior must remain clean and dry.
Operating temperature is 0 to 50 °C, so avoid mounting directly above heat-generating drives or power supplies. Storage temperature spans -20 to 60 °C, and relative humidity is 10 to 90% RH non-condensing. Vibration endurance is 10 to 25 Hz at 2G in X/Y/Z for 30 minutes, which covers typical panel vibration but does not replace proper structural mounting.
Integration and communication notes
this unit provides three serial ports and two USB ports, and it does not include built-in Ethernet. Protocols are not published in the official datasheet, so confirm the required driver or protocol support with the supplier before specifying the unit for a given PLC or controller. For networked architectures, the FLink2 pluggable IIoT module slot offers an expansion path.
Integration Note: wiring into a plant network may require an external gateway or connection module. Confirm cables, adapters and gateway compatibility with PetroPartsOnline before commissioning.
Reliability and lifecycle
this unit is part of the current Flexem product line, and the official FE6300 series comparison page is active as of 2026-09. For maintenance planning, the 50,000-hour LCD lifetime and LED backlight give a reference point for display service intervals. Periodic inspection should cover the front seal, cable glands and supply voltage at the terminal block.
Contact PetroPartsOnline for parts suited to your application's requirements.
Frequently Asked Questions
What is the operating temperature range of the FE6370W?
The Flexem FE6370W operates from 0 to 50 °C and stores from -20 to 60 °C. Keep the panel away from heat sources to stay within this range.
What input voltage does the FE6370W require?
The Flexem FE6370W uses a DC 24V supply with an accepted range of DC 9 to 28 V. Maximum power consumption is <10W, and the unit includes lightning and surge protection.
Does the FE6370W support Ethernet?
No, the Flexem FE6370W does not support Ethernet. It provides serial ports (COM1 RS232/RS485/RS422, COM2 RS485, COM3 RS232) and USB Type-C and Type A ports.
How is the FE6370W mounted and protected?
The Flexem FE6370W mounts in a 190×136 mm panel cutout and reaches front IP65 with flush panel mounting. The rear is IP20, so the cabinet interior must stay clean and dry.
Can I update the FE6370W program without opening the cabinet?
Yes, the Flexem FE6370W supports program download through the USB Slave port or a U-disk. This allows field updates without accessing the rear of the panel.