The Lenze EMF2133IB is a plug-in AIF PROFIBUS DP slave module for 8200 vector, 93XX and ECS drives, with automatic 9.6 kbps to 12 Mbps baud rate detection.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
What the Lenze EMF2133IB PROFIBUS DP Module Delivers
The Lenze this module is a plug-in AIF communication module type 2133 that provides a PROFIBUS DP slave interface for Lenze 8200 vector, 93XX and ECS drive controllers. It connects a host drive to a PROFIBUS DP network at up to 12 Mbps with automatic baud rate detection, so no manual setting is required during commissioning.
For engineers specifying a fieldbus option for legacy Lenze drive platforms, this module is the direct AIF-path choice. It carries the DRIVECOM and PROFIdrive drive profiles, switchable to match the host controller's expected data mapping. The module is built for demanding environments where dependable communication between drives and the control system is mission-critical.

Key Specifications at a Glance
- Supply voltage: DC 24 V nominal (20.4 … 28.8 V), supplied via the host controller AIF interface.
- Current consumption: 120 mA from an external 24 V DC supply.
- Operating temperature: Not published by the manufacturer; the AIF module follows the same ambient class as the host drive enclosure.
- Baud rate: 9.6 kbps … 12 Mbps with automatic detection, no manual setting required.
- Protocol: PROFIBUS DP (DIN 19245 part 1/3); DRIVECOM and PROFIdrive profiles switchable.
- Process data: 1 … 12 words (16 bits/word), depending on host controller.
- Connector: 1 x 9-pole Sub-D female, RS485 medium.
- Protection rating: IP20 built-in plug-in module.
- Dimensions (H×W×D): 75 × 61 × 28 mm.
- Humidity: Average 85 % RH, without condensation (climatic class 3K3 per EN 50178).
The combination of wide-range 24 V DC input tolerance and low 120 mA current draw means the module places minimal additional load on the drive's control supply. Because the supply is routed through the host AIF interface, wiring is confined to the drive's existing control terminals rather than a separate power feed.
Why Choose This Module for Legacy Drive Platforms?
Plants running 8200 vector, 93XX or ECS drive controllers often need to keep those assets in service while maintaining PROFIBUS DP connectivity to the supervisory control layer. This module is the plug-in AIF option designed for exactly that role. Its automatic baud rate detection removes a common commissioning step, and the switchable DRIVECOM/PROFIdrive profiles let engineers match the data format the host controller expects.
The module is a legacy AIF option for previous-generation drives. Lenze has not designated a direct successor AIF module; the E94AYCPM emulates this module on the 9400 platform via DIP switch but is not a drop-in AIF replacement. Engineers planning a platform migration should confirm the communication path with their controls team before committing to a new drive family.

Installation and Commissioning Guidance
this module installs as a plug-in module in the host drive's AIF slot, with the 9-pole Sub-D female connector providing the PROFIBUS DP link. Because the module draws its supply from the host controller AIF interface, verify that the drive's 24 V DC control supply stays within the 20.4 … 28.8 V range at the module terminals. Confirm the PROFIBUS segment is correctly terminated and that the baud rate is left to automatic detection.
For process data configuration, set the word count between 1 and 12 to match the host controller's expected mapping. Select the DRIVECOM or PROFIdrive profile according to the controller's drive profile requirements. Always follow the manufacturer's safety manual for the host drive when installing or servicing the module.
Maintenance and Reliability in Harsh Environments
The IP20 rating means the module relies on the host drive enclosure for environmental protection. Periodic inspection should focus on the Sub-D connector seating, the AIF slot contacts and the drive enclosure's cooling path. Because the module has no published operating temperature range of its own, the host drive's ambient class governs the installation environment. Keeping the enclosure within its rated conditions and free of condensation protects both the drive and the communication module.
In oil and gas installations, vibration and humidity are the usual wear factors. The 85 % RH non-condensing limit and climatic class 3K3 per EN 50178 give engineers a clear boundary for enclosure climate control. Where those limits are respected, the module is built for demanding environments and offers reliability you can depend on across long service intervals.
Integration with PROFIBUS DP Networks
The module presents a single PROFIBUS DP port on a 9-pole Sub-D female connector using RS485 signaling. It operates as a slave on the network, with process data width set by the host controller. When wiring into a PROFIBUS DP segment, confirm cable type, segment length and termination with the network owner. If the host controller requires a different physical interface or a gateway to another protocol, confirm the cabling and gateway selection with PetroPartsOnline before ordering.
Frequently Asked Questions
What drives is this module compatible with?
The Lenze this module is a plug-in AIF module for Lenze 8200 vector, 93XX and ECS drive controllers. It provides a PROFIBUS DP slave interface on those platforms.
What supply voltage does this module require?
The Lenze this module operates from a DC 24 V nominal supply in the range 20.4 … 28.8 V, supplied via the host controller AIF interface, and draws 120 mA from an external 24 V DC supply.
Does this module set its baud rate automatically?
Yes. The Lenze this module detects baud rates from 9.6 kbps to 12 Mbps automatically, so no manual baud rate setting is required during commissioning.
What is the operating temperature range of this module?
The manufacturer does not publish a separate operating temperature range for the Lenze this module. The module follows the same ambient class as the host drive enclosure, so the drive's rated conditions govern the installation.
Is this module still available?
The Lenze this module is a legacy AIF option module for previous-generation 8200, 93XX and ECS drives. Please verify current lifecycle status and availability with PetroPartsOnline before ordering.
Contact PetroPartsOnline for parts suited to your application's requirements.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "EMF2133IB | Lenze PROFIBUS DP AIF Communication Module", "mpn": "EMF2133IB", "sku": "EMF2133IB", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "What the Lenze EMF2133IB PROFIBUS DP Module Delivers The Lenze this module is a plug-in AIF communication module type 2133 that provides a PROFIBUS DP slave interface for Lenze 8200 vector, 93XX and ECS drive controllers. It connects a host drive to a PROFIBUS DP network at up to 12 Mbps with automatic baud rate detection, so no manual setting is required during commissioning. For engineers specifying a fieldbus option for legacy Lenze drive platforms, this module is the direct AIF-path choice. ", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794118255-EMF2133IB_1__fp65baa3a9.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794118264-EMF2133IB_2__fp5cacc721.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794118271-EMF2133IB_3__fp0a658fdf.jpg"], "category": "I/O Modules"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "Why Choose This Module for Legacy Drive Platforms?", "acceptedAnswer": {"@type": "Answer", "text": "Plants running 8200 vector, 93XX or ECS drive controllers often need to keep those assets in service while maintaining PROFIBUS DP connectivity to the supervisory control layer. This module is the plug-in AIF option designed for exactly that role. Its automatic baud rate detection removes a common commissioning step, and the switchable DRIVECOM/PROFIdrive profiles let engineers match the data format the host controller expects. The module is a legacy AIF option for previous-generation drives. Lenze has not designated a direct successor AIF module; the E94AYCPM emulates this module on the 9400 platform via DIP switch but is not a drop-in AIF replacement. Engineers planning a platform migration should confirm the communication path with their controls team before committing to a new drive family."}}, {"@type": "Question", "name": "What drives is this module compatible with?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this module is a plug-in AIF module for Lenze 8200 vector, 93XX and ECS drive controllers. It provides a PROFIBUS DP slave interface on those platforms."}}, {"@type": "Question", "name": "What supply voltage does this module require?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this module operates from a DC 24 V nominal supply in the range 20.4 … 28.8 V, supplied via the host controller AIF interface, and draws 120 mA from an external 24 V DC supply."}}, {"@type": "Question", "name": "Does this module set its baud rate automatically?", "acceptedAnswer": {"@type": "Answer", "text": "Yes. The Lenze this module detects baud rates from 9.6 kbps to 12 Mbps automatically, so no manual baud rate setting is required during commissioning."}}, {"@type": "Question", "name": "What is the operating temperature range of this module?", "acceptedAnswer": {"@type": "Answer", "text": "The manufacturer does not publish a separate operating temperature range for the Lenze this module. The module follows the same ambient class as the host drive enclosure, so the drive's rated conditions govern the installation."}}, {"@type": "Question", "name": "Is this module still available?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this module is a legacy AIF option module for previous-generation 8200, 93XX and ECS drives. Please verify current lifecycle status and availability with PetroPartsOnline before ordering. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}