E84AYCPMV | Lenze PROFIBUS DP-V1 Drive Option Module

Introduction:

The Lenze E84AYCPMV is a PROFIBUS DP-V0/DP-V1 option module for 8400 drives, supporting up to 16 process data words and 12 Mbit/s.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Lenze
Part Number: E84AYCPMV
Type: Drivecom) / dp-v1
Condition: Subject to stock check
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

What does the Lenze E84AYCPMV PROFIBUS module solve?

The Lenze this drive is a PROFIBUS communication option module for Inverter Drives 8400 StateLine C, HighLine C and TopLine C. It occupies the drive's MCI slot and enables reliable integration into PROFIBUS networks using DP-V0 (DRIVECOM) or DP-V1 (PROFIdrive) protocols. The module supports up to 16 process data words and automatic baud rate detection from 9.6 kbit/s to 12000 kbit/s.

Figure 1: Front view of the Lenze E84AYCPMV Drivecom) / dp-v1 showing its physical design and enclosure.

How does this drive address network integration challenges?

Fieldbus integration often fails when modules lack flexibility or diagnostic depth. This drive addresses this with a 9-pin Sub-D connector and support for both DP-V0 and DP-V1, allowing cyclic and acyclic communication. The module operates as a slave node on RS 485 media, with DIP switches for address setting that are electrically isolated from the bus. This isolation helps prevent ground loops and improves noise immunity in rugged industrial environments.

Key features and technical specifications

  • Protocol support: PROFIBUS DP-V0 (DRIVECOM) and DP-V1 (PROFIdrive), plus PROFIdrive V3.
  • Ports: 1 × 9-pin Sub-D connector for PROFIBUS.
  • Baud rate: 9.6 kbit/s … 12000 kbit/s with automatic detection.
  • Process data: 1 … 16 process data words (16-bit).
  • Bus nodes: Max. 31 slaves per segment without repeater; max. 125 with repeaters.
  • Cable length: 1200 m maximum per bus segment, depending on baud rate and cable type.
  • Operating temperature: -10 °C … +55 °C (3K3, EN 60721-3-3).
  • Protection rating: IP20 (EN 60529); insulation voltage to reference earth/PE 50 V.
  • Dimensions (H×W×D): 50 mm × 67 mm × 50 mm.
  • Supply voltage: Not applicable (powered by host drive via MCI slot).

Figure 2: Technical layout and connection details for the Lenze E84AYCPMV Drivecom) / dp-v1.

What are typical applications for this PROFIBUS option module?

This module is suited for connecting 8400 drives to PROFIBUS networks in oil and gas, manufacturing, and process industries. In oil and gas, drives often operate in demanding environments where reliable communication is mission-critical. This drive's operating temperature range of -10 °C to +55 °C and IP20 protection make it suitable for cabinet-mounted installations. It supports line or tree topologies with repeaters, enabling flexible network design across large sites. The module's automatic baud rate detection simplifies commissioning and reduces setup time.

How to install and maintain this drive?

Installation involves inserting the module into the drive's MCI slot and connecting the PROFIBUS cable to the 9-pin Sub-D port. Set the node address using the DIP switches before power-up. Ensure the bus segment does not exceed 1200 m and that termination is correct. For maintenance, inspect connections periodically and verify that the module is seated firmly. The IP20 rating means the module must be installed in a suitable enclosure. Always follow the manufacturer's safety manual for installation and servicing.

Integration note for PROFIBUS networks

When integrating this drive into a PROFIBUS network, confirm cable type and repeater requirements with PetroPartsOnline. The module supports up to 31 slaves per segment without a repeater, and up to 125 with repeaters. For reliable operation, use PROFIBUS-approved cables and connectors. If the network uses a different protocol, an external gateway may be required.

Frequently asked questions

What is the operating temperature range of the Lenze this drive?

The Lenze this drive operates from -10 °C to +55 °C according to 3K3, EN 60721-3-3.

Can this drive be used without a repeater?

Yes, the Lenze this drive supports up to 31 slaves per segment without a repeater; with repeaters, up to 125 nodes are possible.

What is the maximum baud rate of this drive?

The Lenze this drive automatically detects baud rates from 9.6 kbit/s to 12000 kbit/s.

Does this drive require a separate power supply?

No, the Lenze this drive is powered by the host drive via the MCI slot; no separate supply voltage is needed.

What is the protection rating of this drive?

The Lenze this drive has an IP20 protection rating per EN 60529, so it must be installed in a suitable enclosure.

Contact PetroPartsOnline for parts suited to your application's requirements.

Frequently Asked Questions

What is the operating temperature range of the Lenze E84AYCPMV?

The Lenze E84AYCPMV operates from -10 °C to +55 °C according to 3K3, EN 60721-3-3.

Can the E84AYCPMV be used without a repeater?

Yes, the Lenze E84AYCPMV supports up to 31 slaves per segment without a repeater; with repeaters, up to 125 nodes are possible.

What is the maximum baud rate of the E84AYCPMV?

The Lenze E84AYCPMV automatically detects baud rates from 9.6 kbit/s to 12000 kbit/s.

Does the E84AYCPMV require a separate power supply?

No, the Lenze E84AYCPMV is powered by the host drive via the MCI slot; no separate supply voltage is needed.

What is the protection rating of the E84AYCPMV?

The Lenze E84AYCPMV has an IP20 protection rating per EN 60529, so it must be installed in a suitable enclosure.

{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "E84AYCPMV | Lenze PROFIBUS DP-V1 Drive Option Module", "mpn": "E84AYCPMV", "sku": "E84AYCPMV", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "What does the Lenze E84AYCPMV PROFIBUS module solve? The Lenze this drive is a PROFIBUS communication option module for Inverter Drives 8400 StateLine C, HighLine C and TopLine C. It occupies the drive's MCI slot and enables reliable integration into PROFIBUS networks using DP-V0 (DRIVECOM) or DP-V1 (PROFIdrive) protocols. The module supports up to 16 process data words and automatic baud rate detection from 9.6 kbit/s to 12000 kbit/s. How does this drive address network integration challenges? ", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064493-E84AYCPMV_1__fpdc68d656.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064508-E84AYCPMV_2__fp91cc8876.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064514-E84AYCPMV_3__fpfc830f43.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064523-E84AYCPMV_4__fpcf2a2b39.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064532-E84AYCPMV_5__fp73d046dd.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064537-E84AYCPMV_6__fpd476a106.jpg"], "category": "Drives & Motion Control"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the operating temperature range of the Lenze E84AYCPMV?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E84AYCPMV operates from -10 °C to +55 °C according to 3K3, EN 60721-3-3."}}, {"@type": "Question", "name": "Can the E84AYCPMV be used without a repeater?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Lenze E84AYCPMV supports up to 31 slaves per segment without a repeater; with repeaters, up to 125 nodes are possible."}}, {"@type": "Question", "name": "What is the maximum baud rate of the E84AYCPMV?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E84AYCPMV automatically detects baud rates from 9.6 kbit/s to 12000 kbit/s."}}, {"@type": "Question", "name": "Does the E84AYCPMV require a separate power supply?", "acceptedAnswer": {"@type": "Answer", "text": "No, the Lenze E84AYCPMV is powered by the host drive via the MCI slot; no separate supply voltage is needed."}}, {"@type": "Question", "name": "What is the protection rating of the E84AYCPMV?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E84AYCPMV has an IP20 protection rating per EN 60529, so it must be installed in a suitable enclosure."}}]}]}

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap