+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

E82CV551K2C | Lenze 0.55 kW Cold-Plate Inverter

Introduction:

Lenze E82CV551K2C cold-plate frequency inverter delivers 0.55 kW with a bare metal cooling plate for separate customer-side cooling in harsh oil and gas environments.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Lenze
Part Number: E82CV551K2C
Type: Replaced by a bare metal cooling plate connected to a separate customer-side
Condition: Subject to stock check
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Lenze E82CV551K2C: Cold-Plate Inverter for Demanding Environments

The Lenze this unit is a frequency inverter from the 8200 vector series that uses cold-plate technology, replacing the standard heatsink with a bare metal plate for connection to a separate customer-side cooler. It delivers 0.55 kW typical motor power and 3.0 A rated output current at 8 kHz switching frequency. This design suits mission-critical oil and gas installations where heat removal must be handled outside the drive enclosure.

Figure 1: Front view of the Lenze E82CV551K2C Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

Key Specifications and Cold-Plate Thermal Data

  • Rated motor power: 0.55 kW typical (4-pole three-phase asynchronous motor)
  • Rated output current: 3.0 A nominal at 8 kHz switching frequency
  • Max. output current: 4.5 A for 60 s (periodic load cycle: 1 min overload at Imax / 2 min base load at 75% Ir)
  • Supply voltage: 1/N/PE or 3/PE AC 180 V -0% … 264 V +0%; 45 … 65 Hz
  • Operating temperature: -10 … +55 °C (derated by 2.5%/°C above +40 °C)
  • Storage temperature: -25 … +60 °C
  • Relative humidity: average 85 % RH, without condensation (climatic class 3K3 per EN 50178)
  • Protection rating: IP20
  • Dissipated power loss: 30 W; thermal resistance Rth ≤ 1.0 K/W between cooler and cooling medium; max. permissible cooling-plate temperature 75 °C
  • Built-in I/O: 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, 1 relay output (changeover contact, 250 V AC / 3 A)
  • Control: V/f characteristic control (linear/quadratic) and sensorless vector control; output frequency range -650 … +650 Hz
  • Integrated brake transistor

How Does the Cold-Plate Design Improve Reliability?

By removing the heatsink, this unit transfers heat directly to a customer-supplied cooling medium through a bare metal plate. This arrangement keeps the drive's internal components away from ambient contaminants and reduces the risk of heatsink clogging. For maintenance engineers, the key parameter is the thermal resistance Rth ≤ 1.0 K/W between cooler and cooling medium. The maximum permissible cooling-plate temperature is 75 °C, so the external cooling circuit must maintain that limit under all load conditions.

Operating temperature is rated for -10 … +55 °C, with derating of 2.5 %/°C above +40 °C. In oil and gas installations, ambient temperatures can exceed 40 °C, so engineers should calculate derating carefully. The supply voltage range of 180 V to 264 V AC accommodates typical industrial power systems, and the 45 … 65 Hz frequency range covers standard and slightly off-nominal supplies. These rugged specifications make the inverter suitable for field-proven performance in demanding environments.

Figure 2: Technical layout and connection details for the Lenze E82CV551K2C Replaced by a bare metal cooling plate connected to a separate customer-side.

Installation and Commissioning

Mount the inverter so that the cooling plate makes firm contact with the customer-side cooler. Use a thermal interface material if recommended by the cooler manufacturer. Verify that the cooling circuit can dissipate 30 W continuously while keeping the plate below 75 °C. The X3 control terminal strip provides access to analog and digital I/O, including one analog input, one analog output, four digital inputs, one digital output, and one relay output with changeover contact rated 250 V AC / 3 A. For fieldbus connectivity, the FIF slot accepts plug-in function modules from the E82ZAF* family, since no protocol is built in.

During commissioning, set the V/f characteristic or sensorless vector control according to the motor data. The output frequency range of -650 … +650 Hz allows flexible speed profiles. Always follow the manufacturer's safety manual for wiring and parameter settings.

Maintenance and Serviceability

From a maintenance perspective, the cold-plate design simplifies inspections: there are no heatsink fins to clean, and the cooling circuit can be checked independently. Periodically verify the thermal resistance by monitoring the cooling-plate temperature under known load. Inspect the plate-to-cooler interface for proper contact and thermal compound condition. Because the inverter is rated IP20, it must be installed in a control cabinet or enclosure that protects it from dust and moisture. The relative humidity limit of 85 % RH without condensation (climatic class 3K3 per EN 50178) should be respected.

The integrated brake transistor and the relay output support braking and interlock functions without extra hardware. For mission-critical operations, keep spare function modules and terminal connectors on hand. This unit is part of the 8200 vector series, which Lenze lists on its previous products page; cold-plate special design is available on request. Please verify current lifecycle status and availability with PetroPartsOnline before ordering.

Integration and Compatibility

this unit provides a FIF slot for E82ZAF* function modules, enabling fieldbus integration when required. However, no protocol is built in, so a plug-in module is necessary for network communication. Wiring into a fieldbus network may require an external gateway or connection module; confirm cables and gateways with the supplier. The X3 terminal strip handles all standard I/O, making the inverter suitable for stand-alone control or as part of a larger system.

For engineers migrating from older 8200 vector drives, Lenze confirms that the i950 inverter emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. There is no drop-in same-order-code replacement, so plan for configuration adjustments. This unit remains a dependable choice for applications requiring cold-plate cooling and a compact footprint.

Frequently Asked Questions

What is the operating temperature range of the Lenze this unit?

The Lenze this unit operates from -10 … +55 °C, with derating of 2.5 %/°C above +40 °C. This range suits many oil and gas environments, but ensure the enclosure temperature stays within limits.

Can this unit be connected directly to a fieldbus?

No, this unit has no built-in fieldbus protocol. It requires a plug-in function module from the E82ZAF* family in the FIF slot for network communication.

What supply voltage does the Lenze this unit accept?

The Lenze this unit accepts 1/N/PE or 3/PE AC 180 V -0% … 264 V +0% at 45 … 65 Hz, covering standard industrial power supplies.

How much heat does this unit dissipate?

this unit dissipates 30 W, and the thermal resistance between cooler and cooling medium is Rth ≤ 1.0 K/W. The cooling plate must be kept below 75 °C.

Is this unit still available?

The Lenze this unit is listed as a previous product, and cold-plate special design is available on request. Contact PetroPartsOnline for parts suited to your application's requirements.

{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "E82CV551K2C | Lenze 0.55 kW Cold-Plate Inverter", "mpn": "E82CV551K2C", "sku": "E82CV551K2C", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "Lenze E82CV551K2C: Cold-Plate Inverter for Demanding Environments The Lenze this unit is a frequency inverter from the 8200 vector series that uses cold-plate technology, replacing the standard heatsink with a bare metal plate for connection to a separate customer-side cooler. It delivers 0.55 kW typical motor power and 3.0 A rated output current at 8 kHz switching frequency. This design suits mission-critical oil and gas installations where heat removal must be handled outside the drive enclosu", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064349-E82CV551K2C_1__fp6be151f6.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064357-E82CV551K2C_2__fp0c5cf947.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064366-E82CV551K2C_3__fp4e8620f6.jpg"], "category": "I/O Modules"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "How Does the Cold-Plate Design Improve Reliability?", "acceptedAnswer": {"@type": "Answer", "text": "By removing the heatsink, this unit transfers heat directly to a customer-supplied cooling medium through a bare metal plate. This arrangement keeps the drive's internal components away from ambient contaminants and reduces the risk of heatsink clogging. For maintenance engineers, the key parameter is the thermal resistance Rth ≤ 1.0 K/W between cooler and cooling medium. The maximum permissible cooling-plate temperature is 75 °C, so the external cooling circuit must maintain that limit under all load conditions. Operating temperature is rated for -10 … +55 °C, with derating of 2.5 %/°C above +40 °C. In oil and gas installations, ambient temperatures can exceed 40 °C, so engineers should calculate derating carefully. The supply voltage range of 180 V to 264 V AC accommodates typical industrial power systems, and the 45 … 65 Hz frequency range covers standard and slightly off-nominal supplies. These rugged specifications make the inverter suitable for field-proven performance in demanding environments."}}, {"@type": "Question", "name": "What is the operating temperature range of the Lenze this unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this unit operates from -10 … +55 °C, with derating of 2.5 %/°C above +40 °C. This range suits many oil and gas environments, but ensure the enclosure temperature stays within limits."}}, {"@type": "Question", "name": "Can this unit be connected directly to a fieldbus?", "acceptedAnswer": {"@type": "Answer", "text": "No, this unit has no built-in fieldbus protocol. It requires a plug-in function module from the E82ZAF* family in the FIF slot for network communication."}}, {"@type": "Question", "name": "What supply voltage does the Lenze this unit accept?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this unit accepts 1/N/PE or 3/PE AC 180 V -0% … 264 V +0% at 45 … 65 Hz, covering standard industrial power supplies."}}, {"@type": "Question", "name": "How much heat does this unit dissipate?", "acceptedAnswer": {"@type": "Answer", "text": "this unit dissipates 30 W, and the thermal resistance between cooler and cooling medium is Rth ≤ 1.0 K/W. The cooling plate must be kept below 75 °C."}}, {"@type": "Question", "name": "Is this unit still available?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze this unit is listed as a previous product, and cold-plate special design is available on request. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap