Bently Nevada 9200-02-01-10-00 Velocity Transducer



Introduction:
Bently Nevada 9200-02-01-10-00 two-wire velocity seismoprobe. Sensitivity 20mV/mm/s. For turbomachinery vibration monitoring.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Main Content
Bently Nevada 9200-02-01-10-00 Two-Wire Velocity Seismoprobe Transducer
The Bently Nevada 9200-02-01-10-00 is a rugged two-wire velocity transducer. This device measures absolute casing vibration on rotating machinery. It works perfectly for turbines, compressors, and pumps. The Bently Nevada 9200-02-01-10-00 provides reliable data without external signal conditioning.
Key Technical Specifications
This transducer offers a sensitivity of 20 mV/mm/s (500 mV/in/s). The tolerance stays within ±5% when properly terminated. Calibration uses a 10 kΩ load between terminals A and B. Output is taken directly across pins A and B. The dynamic operating range reaches 2.54 mm (0.100 in) peak-to-peak maximum displacement.
Velocity range hits 25 mm/s (1 in/s) at +22°C. This measurement uses 100 Hz casing vibration with a 10 kΩ load. Coil resistance sits at 1.25 kΩ ±5%. Locked coil inductance is 125 mH typical. The sensitivity temperature coefficient is 0.2% per °C.
Mounting and Connector Options
The mounting angle option is 02 at 45° ±2.5°. Minimum operating frequency starts at 4.5 Hz (270 cpm). Connector option 01 provides a top mount with no cable. Mounting base option 10 uses a circular base with M10x1 stud. Agency approval option 00 means no approvals are required.
This configuration suits permanent installation on machinery casings. The top mount design keeps the transducer secure. You can easily access the connector from above.
Environmental and Temperature Ratings
Operating and storage temperature ranges from -29°C to +121°C (-20°F to +250°F). The case uses anodized aluminum A204 for corrosion resistance. Gasket material is Neoprene for the 9200 series. The device resists dust and moisture effectively. Relative humidity tolerance reaches 95% noncondensing.
The transducer handles 100% humidity when ordered with an integral cable (non-submerged). This makes it suitable for humid industrial environments. Avoid direct water immersion without proper cable protection.
Mechanical Dimensions and Weight
Typical height measures 102 mm (4 inches). This depends on the selected connector option. Diameter is 41 mm (1.6 inches) typical. Weight of the 9200 model is 300 grams (10.5 ounces) typical. These compact dimensions allow installation in tight spaces.
The Bently Nevada 9200-02-01-10-00 fits standard mounting pads. Its lightweight design reduces stress on mounting studs. The circular base with M10x1 stud provides strong attachment.
Installation Guide
Follow these steps for proper installation:
Clean the mounting surface on the machinery casing.
Screw the M10x1 stud into the prepared mounting hole.
Tighten the circular base hand-tight plus a quarter turn.
Connect wires to terminal A and terminal B as shown.
Terminate the output with a 10 kΩ load resistor.
Orient the transducer at the 45° angle per option 02.
Verify output signal across pins A and B before startup.
Secure cables away from moving parts and heat sources.
Do not overtighten the mounting stud. Keep the cable bend radius large. Avoid exceeding +121°C casing temperature.
Package Contents
The factory packing includes these items:
One Bently Nevada 9200-02-01-10-00 transducer unit
One M10x1 mounting stud (pre-installed on circular base)
One protective dust cap for the top connector
One quick reference card with pinout details
No certificates or warranty documents are inside the box. No shipping method like FedEx, UPS, or DHL is listed.
Common FAQs (3-5 questions)
Q1: Can I use this transducer without a 10 kΩ load?
No, you need a 10 kΩ load between terminal A and B. Without this load, the sensitivity will drift outside the ±5% specification.
Q2: What happens if the temperature exceeds +121°C?
The internal coil and electronics may degrade permanently. The Bently Nevada 9200-02-01-10-00 is rated only up to +121°C for operation.
Q3: Does this sensor work with any vibration monitor?
Yes, it works with any monitor that accepts 20 mV/mm/s input. Bently Nevada monitors are ideal, but other brands also work.
Q4: How do I check if the transducer is damaged?
Measure coil resistance between pin A and pin B. A healthy unit shows 1.25 kΩ ±5%. Any open or short circuit means damage.
Q5: Is the top connector waterproof?
The connector itself is dust and moisture resistant. For wet areas, you must use a sealed mating connector or integral cable.
Summary for Buyers
The Bently Nevada 9200-02-01-10-00 two-wire velocity transducer delivers accurate casing vibration data. Its 20 mV/mm/s sensitivity and 4.5 Hz low frequency capture slow speed machinery signals. The IP-rated design and wide temperature range suit harsh industrial sites. Order this new original unit for reliable condition monitoring on your critical assets.