22A-V2P3H204 | Allen-Bradley 0.4 kW 120V AC Drive



Introduction:
The Allen-Bradley 22A-V2P3H204 is a PowerFlex 4 AC drive rated 0.4 kW at 2.3 A with 100…120V AC single-phase input and a built-in RS-485 port.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Allen-Bradley 22A-V2P3H204 is a AC adjustable-frequency drive — PowerFlex 4 for industrial control and automation applications.
What the Allen-Bradley 22A-V2P3H204 Delivers
The Allen-Bradley this drive is a PowerFlex 4 AC adjustable-frequency drive rated 0.4 kW (0.5 HP) at 2.3 A continuous output. It accepts 100…120V AC single-phase input and provides a built-in RS-485 DSI port for serial control. For oil and gas sites, this means a compact, field-proven drive for small pumps, fans and conveyors where reliable speed control protects both process uptime and energy spend.

Key Specifications and Cost Implications
- Input voltage: 100…120V AC, 1-phase, with ±10 % tolerance and a 90…126V AC range.
- Rated output: 0.4 kW (0.5 HP) at 2.3 A continuous, 0…230V three-phase output.
- Operating temperature: -10…+50 °C for IP20/Open Type; -10…+40 °C for IP30/NEMA 1/UL Type 1.
- Power supply: 1.15 kVA input at 9.0 A, 15 A branch fuse, 50/60 Hz supply frequency.
- Efficiency: 97.5 % typical, with 40 W total power dissipation at rated load.
- Overload: 150 % for 60 s and 200 % for 3 s, published as Class 10 I2t motor protection.
- Communication: RS-485 DSI port supporting Modbus RTU function codes 03, 06 and 16.
- Enclosure: Replacement Plate Drive, IP20 / NEMA/UL Type Open, Frame A.
Each of these parameters carries a cost angle. The 97.5 % typical efficiency means most input power reaches the motor, reducing wasted heat and the load on enclosure cooling. The 40 W total dissipation splits into 22 W external and 18 W internal, which matters when sizing cabinets. A 100 ms faultless power ride-through and 0.5 s minimum logic control ride-through help the drive ride through brief supply dips instead of tripping a mission-critical process.
How Does this drive Handle Harsh Conditions?
Operating temperature is the first constraint on any oil and gas installation. This drive runs from -10…+50 °C in its IP20 open enclosure. If you add the field-installed IP30/NEMA 1 kit 22-JBAA, the upper limit becomes -10…+40 °C. Storage temperature spans -40…+85 °C, and relative humidity is 0…95 % non-condensing. The drive tolerates 15 g peak shock for 11 ms and 1 g peak vibration from 5…2000 Hz while operating. Altitude is limited to 1000 m without derating.
These ratings are rugged enough for sheltered skids and control rooms, but the manual is explicit: do not install where the ambient atmosphere contains volatile or corrosive gas, vapors or dust. For remote wellhead panels, that means a sealed enclosure and a planned inspection route. Protecting the drive from corrosive atmosphere is cheaper than replacing it, and it keeps the process online.

Where Does This Drive Fit in Oil and Gas Operations?
Small single-phase drives often serve duty that is easy to overlook until it stops. A 0.4 kW rating suits chemical dosing pumps, sample-conditioning fans, lube-oil circulation and small conveyor sections. Because the drive provides 0…240 Hz programmable output and ±2 % speed regulation across a 40:1 range with slip compensation, operators can trim flow or pressure without throttling valves. That reduces mechanical wear and avoids the energy loss of running a motor at full speed against a restriction.
Two independently programmable accel and decel times, each 0…600 s in 0.1 s increments, let you soften starts on pumps and fans. Programmable stop modes include Ramp, Coast, DC-Brake, Ramp-to-Hold and S Curve. The integral brake IGBT supports dynamic braking with an external resistor; the published resistor for this rating is minimum 60 Ω, catalog AK-R2-091P500 rated for a 5 % duty cycle. In a mission-critical dosing line, controlled deceleration can prevent water hammer and the repair cost that follows.
Installation and Integration Notes
Wiring follows the published ratings. Use a 15 A branch fuse and the recommended Bulletin 140M/140MT motor protector or 100-C/100-E contactor per the manual. The analog input is DIP-selectable for 0…10V DC at 100 kΩ or 4…20 mA at 250 Ω, and an external potentiometer of 1…10 kΩ at 2 W minimum is supported. Digital inputs include three dedicated terminals plus two programmable ones, with SRC and SNK modes defined.
The built-in RS-485 port supports Modbus RTU multi-drop. Node address A104 ranges 1…247, baud rate A103 spans 1200…38400 bit/s with a 9600 default, and format A107 is RTU 8-N-1. RS-485 repeaters may be required beyond 32 nodes. No communication option-card slot is published for the PowerFlex 4; external adapters mount through the 22-XCOMM-DC-BASE kit. If you plan to connect this drive to a plant network, confirm cables, gateways and terminating resistors with PetroPartsOnline before ordering.
Reliability and Maintenance Planning
Convection cooling covers the 0.2 kW ratings and all flange-mount drives; fan cooling covers all other ratings, so this 0.4 kW unit has a cooling fan that belongs on the inspection list. Check airflow and heatsink condition at each scheduled outage. The drive publishes cULus Listing to UL 508C and CSA C22.2 No. 14, CE conformity to EN 61800-3 and EN 61800-5-1, and KC registration KCC-REM-RAA-22A. No Safe Torque Off function or functional-safety rating is published, so stopping behavior relies on parameter P037 stop-mode selection. Follow the manufacturer's safety manual for any maintenance activity.
An external EMC filter is required for CE compliance. Table 17 publishes no external S Type filter for this rating and gives the L Type filter 22-RF010-AL. With an L-type filter, allowable motor cable length reaches 100 m in the published environments. Planning cable runs around that limit avoids rework and keeps commissioning on schedule.
Frequently Asked Questions
What input voltage does this drive require?
The Allen-Bradley this drive requires 100…120V AC single-phase input with ±10 % tolerance, giving a published input range of 90…126V AC at 50/60 Hz. It draws 1.15 kVA at 9.0 A and needs a 15 A branch fuse.
What is the operating temperature range of this PowerFlex 4 drive?
The Allen-Bradley this drive operates from -10…+50 °C in its IP20 open enclosure. Fitting the field-installed IP30/NEMA 1 kit 22-JBAA reduces the upper limit to -10…+40 °C. Storage temperature is -40…+85 °C.
Does this drive support Modbus communication?
Yes. The Allen-Bradley this drive has a built-in RS-485 DSI port that supports Modbus RTU with function codes 03, 06 and 16. Node addresses range from 1 to 247 and baud rates from 1200 to 38400 bit/s.
What overload capability does this drive provide?
The Allen-Bradley this drive delivers 150 % of rated output current for 60 s and 200 % for 3 s. The manual publishes this as I2t motor protection providing Class 10 protection, which helps ride through brief load surges without nuisance trips.