22A-B2P3N104 | Allen-Bradley 0.4 kW AC Drive, 240V



Introduction:
The Allen-Bradley 22A-B2P3N104 is a 0.4 kW PowerFlex 4 AC drive for 200…240V three-phase input, featuring an integral brake IGBT and RS-485 DSI port.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Allen-Bradley 22A-B2P3N104 is a AC adjustable-frequency drive — PowerFlex 4 for industrial control and automation applications.
The Allen-Bradley 22A-B2P3N104 is a PowerFlex 4 AC adjustable-frequency drive rated 0.4 kW (0.5 HP) with 2.3 A continuous output current. It accepts 200…240V AC three-phase input and provides a 0…230V three-phase output for variable-speed motor control in industrial applications.
What should you verify before selecting this drive?
This drive is a panel-mount unit with an IP20 / NEMA/UL Type Open enclosure, so it must be installed inside a protective cabinet. The rated output of 0.4 kW suits light-duty loads, and the 2.3 A continuous current sets the motor size limit. The drive includes an integral brake IGBT, but dynamic braking requires an external resistor; the published minimum is 60 Ω with the AK-R2-091P500 resistor rated for a 5 % duty cycle. No integral EMC filter is fitted, so CE compliance requires an external filter such as the 22-RF9P5-AS or 22-RF9P5-AL.

Key specifications at a glance
- Input voltage: 200…240V AC, 3-phase, ±10 % tolerance, 50/60 Hz supply.
- Output: 0…230V three-phase, 0…240 Hz programmable, 2.3 A continuous.
- Overload: 150 % for 60 s and 200 % for 3 s with I2t motor protection.
- Operating temperature: -10…+50 °C for IP20/Open Type; -10…+40 °C for IP30/NEMA 1.
- Control inputs: 3 dedicated digital plus 2 programmable; 1 analog input (0…10V DC or 4…20 mA).
- Relay output: 1 programmable Form C rated 3.0 A resistive at 30V DC / 125V AC / 240V AC.
- Communication: built-in RS-485 DSI port supporting Modbus RTU.
- Efficiency: 97.5 % typical.
How does the drive perform in demanding environments?
this drive is built for demanding environments where temperature and electrical noise are concerns. Its operating range of -10…+50 °C covers most plant-floor cabinets, while storage tolerance extends from -40…+85 °C. The drive withstands 15 g shock and 1 g vibration from 5…2000 Hz, and its 100 ms power ride-through helps ride through short supply dips. Logic control ride-through is 0.5 s minimum and 2 s typical. These rugged characteristics support dependable operation in mission-critical processes.
Cooling is fan-based for this rating, so ensure adequate airflow around the heatsink. The drive must not be installed where the atmosphere contains volatile or corrosive gas, vapors or dust. Altitude is limited to 1000 m without derating.

Which applications suit this PowerFlex 4 model?
Typical uses include conveyors, fans, pumps and simple mixers that require basic variable-speed control. The built-in keypad with LED display allows local setup and monitoring. Because the drive offers open-loop speed regulation of ±2 % across a 40:1 range with slip compensation, it handles applications where precise speed holding is not critical but repeatability matters. The RS-485 port enables multi-drop networking with up to 32 nodes before repeaters are needed, using Modbus RTU function codes 03, 06 and 16.
For oil and gas auxiliary systems, the drive can control small pumps or blowers where a compact, panel-mount solution is preferred. However, note that no Safe Torque Off function is published for the PowerFlex 4, so safety-related stopping must be handled externally.
What are the installation and integration considerations?
Mount the drive vertically on a panel with the recommended clearances. Connect input power through branch circuit protection; the ratings table lists 6 A fuses (UL Class J, CC, T or Type BS88) and Bulletin 140M/140MT motor protectors. Motor cable length is limited to 10 m in First Environment Restricted Distribution or Second Environment with an integral or external S-type filter, and 100 m with an external L-type filter. For CE compliance, an external filter is mandatory because this model has no integral EMC filter.
Integration with control systems is straightforward via the digital and analog I/O. The RS-485 DSI port supports Modbus RTU at baud rates from 1200 to 38400 bit/s (default 9600) with node addresses 1…247. For other networks, external communication kits are available, such as the 22-XCOMM-DC-BASE for 22-COMM adapters. Wiring into fieldbus networks may require an external gateway or connection module; confirm cable and gateway compatibility with PetroPartsOnline.
How should you maintain and troubleshoot the drive?
Periodic inspection should include checking heatsink fins for dust buildup, verifying fan operation, and tightening power terminals. The drive's protective features include DC bus overvoltage trip at 405 V DC and undervoltage trip at 210 V DC, overcurrent limit at 200 % hardware and 300 % instantaneous fault. If the drive trips, review the fault code on the LED display and consult the user manual. Common issues include overheating due to blocked airflow and nuisance trips from unstable input power; the 100 ms ride-through helps but does not eliminate all disturbances.
For spare parts or technical support, contact PetroPartsOnline. Please verify current lifecycle status and availability with PetroPartsOnline before ordering, as this model is discontinued with a replacement 25A-B2P5N104.
Frequently asked questions
What is the input voltage range of this drive?
The Allen-Bradley this drive accepts 200…240V AC three-phase input with ±10 % tolerance, corresponding to an input voltage range of 180…265V AC.
Does this drive include a built-in EMC filter?
No, the Allen-Bradley this drive does not include an integral EMC filter. An external filter such as the 22-RF9P5-AS or 22-RF9P5-AL is required for CE compliance.
What is the operating temperature range for this drive?
The Allen-Bradley this drive operates from -10…+50 °C in IP20/Open Type enclosures and from -10…+40 °C when fitted with the IP30/NEMA 1 kit.
Can this drive be networked with a PLC?
Yes, the Allen-Bradley this drive has a built-in RS-485 DSI port that supports Modbus RTU, allowing multi-drop networking with up to 32 nodes before repeaters are needed.
Is this drive still available for purchase?
The Allen-Bradley this drive is discontinued with a discontinuation date of 2025-06-30. Contact PetroPartsOnline to verify current availability and discuss the published replacement 25A-B2P5N104.
Frequently Asked Questions
What is the input voltage range of the 22A-B2P3N104?
The Allen-Bradley 22A-B2P3N104 accepts 200…240V AC three-phase input with ±10 % tolerance, corresponding to an input voltage range of 180…265V AC.
Does the 22A-B2P3N104 include a built-in EMC filter?
No, the Allen-Bradley 22A-B2P3N104 does not include an integral EMC filter. An external filter such as the 22-RF9P5-AS or 22-RF9P5-AL is required for CE compliance.
What is the operating temperature range for the 22A-B2P3N104?
The Allen-Bradley 22A-B2P3N104 operates from -10…+50 °C in IP20/Open Type enclosures and from -10…+40 °C when fitted with the IP30/NEMA 1 kit.
Can the 22A-B2P3N104 be networked with a PLC?
Yes, the Allen-Bradley 22A-B2P3N104 has a built-in RS-485 DSI port that supports Modbus RTU, allowing multi-drop networking with up to 32 nodes before repeaters are needed.
Is the 22A-B2P3N104 still available for purchase?
The Allen-Bradley 22A-B2P3N104 is discontinued with a discontinuation date of 2025-06-30. Contact PetroPartsOnline to verify current availability and discuss the published replacement 25A-B2P5N104.