+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

K-LB-2.30G Surge Protection Barrier 2 Channel 20kA SIL 3

Introduction:

The K-LB-2.30G is a surge protection barrier for 30V applications. It protects 4 signal lines across 2 channels. Maximum surge current reaches 20 kA (8/20 µs) with auto reset operation. This device mounts on a 35 mm DIN rail and supports SIL 3 per IEC/EN 61508.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Beckoff
Series: K-LB Series
Part Number: K-LB-2.30G
Type: Surge Protection Barrier
Condition: In Stock
Origin: U.S.A
Weight: 0.1
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Technical Specifications

The K-LB-2.30G limits induced transients from lightning or switching operations. It diverts current to earth during overvoltage pulses. The device is HART transparent for uninterrupted communication.

General Specifications

ParameterValue
Protected Signal Lines4 (2 channels x 2 lines)
TopologyGrounded
Mounting35 mm DIN rail (EN 60715)

Functional Safety

ParameterValue
Safety Integrity Level (SIL)SIL 3

Electrical Specifications

Connection Assignment

AreaTerminals
Protected Area5, 6 and 7, 8
Unprotected Area1, 2 and 3, 4

Ratings

ParameterValue
Rated Current (Ir)250 mA
Leakage Current<10 µA at 24V and 25°C (line-line)
Nominal Voltage24 V DC
Max Continuous Operating Voltage (Uc)30 V DC
Series Resistance<0.5 Ω per line

Surge Ratings

ParameterValue
Impulse Rating10 kV / 5 kA (C2)
Category D1 Rating2 kV / 2 kA
Impulse Discharge Current (10/350 µs)2 kA per line (2x)
Nominal Discharge Current (8/20 µs) In5 kA per line (10x)
Rated Surge Current (8/20 µs) ISM10 kA per line (1x)
Total Discharge Current (8/20 µs) Itotal20 kA (1x)

Voltage Protection Level (Up)

ConditionValue
Line-Line (at In)max. 100 V
Line-Earth (at In)max. 50 V

Performance Characteristics

ParameterValue
Impulse Reset Time<30 ms
Insertion Loss (0-4 kHz, 600Ω system)≤0.05 dB
Insertion Loss (0-174 kHz, 100Ω system)≤3 dB

Ambient Conditions

ParameterRange
Ambient Temperature-30°C to +80°C
Relative Humidity5% to 95%
Mounting LocationIndoor

Mechanical Specifications

ParameterValue
Degree of ProtectionIP20
Connection TypeScrew terminals
Core Cross Section2 x 2.5 mm²
Massapprox. 100 g
Dimensions (W x H x D)12.5 x 115 x 116 mm (0.5 x 4.5 x 4.6 in)

Hazardous Area Certification (ATEX)

ParameterValue
CertificatePTB 00 ATEX 2176 X
MarkingII 2(1)G Ex ia IIC T6/T5/T4
Temperature Class T6Ambient ≤ 50°C
Temperature Class T5Ambient ≤ 70°C
Temperature Class T4Ambient ≤ 80°C

ATEX Electrical Parameters

ParameterValue
Voltage (Ui)30 V
Current (Ii)250 mA
Internal Capacitance (Ci)Negligible
Internal Inductance (Li)200 µH

Hazardous Area Certification (IECEx)

ParameterValue
CertificateIECEx BAS 14.0010X

CSA Approval

ParameterValue
Control Drawing116-0187 (cCSAus)

Conformity Standards

StandardDescription
IEC 60529:2013Degree of protection
EN 61643-21:2001+A1:2009+A2:2013Surge protective devices
IEC 61643-21:2001+A1:2008+A2:2012Surge protective devices
EN 60079-0:2012+A11:2013Explosive atmospheres
EN 60079-11:2012Intrinsic safety

Directive Compliance

DirectiveCompliance
2014/34/EU (ATEX)EN 60079-0, EN 60079-11

Installation Guidelines

Follow these steps to install your K-LB-2.30G surge protection barrier correctly.

  1. Mount the DIN Rail – Install 35 mm DIN rail per EN 60715 standard.

  2. Clip the Device – Snap the K-LB-2.30G onto the DIN rail firmly.

  3. Connect Earth Ground – Attach high quality ground connection first.

  4. Wire Unprotected Side – Connect terminals 1,2 and 3,4 to field side.

  5. Wire Protected Side – Connect terminals 5,6 and 7,8 to control side.

  6. Match Potential – Ensure device has same potential as protected equipment.

  7. Label the Device – Use front labeling space for circuit identification.

  8. Verify Ground System – Check ground installation per applicable regulations.

Always connect the K-LB-2.30G to high quality ground connections. Install the ground system in accordance with applicable regulations.

Wiring Diagram

ChannelUnprotected TerminalsProtected Terminals
Channel 11 and 25 and 6
Channel 23 and 47 and 8

Package Contents (No Certificates or Warranty Terms)

Your shipment for product number K-LB-2.30G includes the following items:

  • 1 x K-LB-2.30G Surge Protection Barrier

  • 1 x Installation instruction sheet (printed)

  • 1 x Labeling strip for front marking

Note: DIN rail is not included. Screw terminals are pre-installed on the device.


Frequently Asked Questions (FAQ)

1. What is the maximum surge current rating for the K-LB-2.30G?
Total discharge current reaches 20 kA (8/20 µs) for one event. Per line rating is 10 kA for one event or 5 kA for ten events.

2. Is the K-LB-2.30G HART transparent?
Yes. The K-LB-2.30G is HART transparent for uninterrupted communication. Insertion loss is minimal across HART frequencies.

3. What is the SIL rating for this surge protection barrier?
The K-LB-2.30G is rated SIL 3 per IEC/EN 61508. This suits safety critical applications.

4. What is the maximum continuous operating voltage?
Maximum continuous operating voltage (Uc) is 30 V DC. Nominal operating voltage is 24 V DC.

5. Can the K-LB-2.30G be used in hazardous areas?
Yes. This device carries ATEX and IECEx certifications. Marking is II 2(1)G Ex ia IIC T6/T5/T4.

6. What is the impulse reset time after a surge event?
Reset time is <30 ms. The device returns to normal operation automatically without manual intervention.


Why Choose This Model?

The K-LB-2.30G offers robust surge protection for 30V signal circuits. Its 2-channel design protects 4 signal lines in a compact 12.5 mm width. The 20 kA total discharge current handles severe lightning and switching transients. The SIL 3 rating supports safety instrumented systems per IEC 61508. The ATEX and IECEx certifications allow installation in hazardous areas with Ex ia IIC approval. The HART transparency ensures no interference with smart instrument communication. The auto reset operation returns to service without manual intervention. The wide temperature range (-30°C to +80°C) suits outdoor and industrial environments. Choose this K-LB-2.30G for protecting analog inputs, RTD circuits, solenoid drivers, and switch inputs in refineries, chemical plants, power stations, and offshore platforms.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap