The Flexem FE6400CE is a 10.1-inch resistive-touch HMI rated for 0 to 50 °C operation and DC 9 to 28 V input, built for dependable panel service in oil and gas control rooms.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
When a legacy panel display fails on a gas-compressor skid, engineers need a drop-in terminal that tolerates voltage sag and shop-floor heat without a redesign. The Flexem FE6400CE answers that challenge: a 10.1-inch wide-viewing-angle resistive-touch HMI with built-in Ethernet, a 1GHz dual-core ARM Cortex-A7 CPU, and a DC 24V supply that accepts DC 9 to 28 V. It is a field-proven candidate for hmi touchscreen replacement projects where the panel cutout is already fixed at 260×202 mm.
What makes this unit suited to oil and gas panels?
this unit pairs a 10.1" 16:9 TFT LCD with 1024×600 resolution and 400 cd/m² brightness, so operators can read process values under typical control-room lighting. Viewing angles of 85° on all four sides keep the screen legible from side-mounted consoles. A 4-wire industrial resistive touch panel allows gloved operation, which matters on rig floors and in compressor halls.
Environmental ratings support that role. Operating temperature spans 0 to 50 °C, storage temperature spans -20 to 60 °C, and relative humidity is 10 to 90% RH non-condensing. The front face carries IP65 protection when mounted with a flush panel, while the rear is IP20. Vibration endurance is specified at 10 to 25 Hz, 2G in X/Y/Z for 30 minutes, giving the unit a rugged footing in vibrating skids.

Key specifications at a glance
- Display: 10.1" 16:9 TFT LCD, 1024×600, 24-bit color
- Brightness: 400 cd/m² with LED backlight
- LCD lifetime: 50,000 hours
- CPU: 1GHz dual-core ARM Cortex-A7
- Memory: 256MB DDR3 + 256MB Flash
- Supply voltage: DC 24V (range DC 9 to 28 V)
- Power consumption: <10W maximum
- Ethernet: 1×10/100M adaptive (RJ45)
- Serial ports: COM1 RS232/RS485/RS422; COM2 RS485; COM3 RS232
- Operating temperature: 0 to 50 °C
Frequently Asked Questions
What supply voltage does the FE6400CE require?
The Flexem FE6400CE runs from DC 24V nominal with an input range of DC 9 to 28 V, and maximum power consumption is under 10W.
Is the FE6400CE a practical hmi touchscreen replacement for existing panels?
With a 260×202 mm panel cutout and 213×273×36 mm overall dimensions, the Flexem FE6400CE can be evaluated against the existing panel opening before any fabrication work begins.
What operating temperature range does this HMI support?
The Flexem FE6400CE is rated for 0 to 50 °C operating temperature and -20 to 60 °C storage temperature, with 10 to 90% RH non-condensing humidity.
Does the FE6400CE include serial and Ethernet ports?
Yes. The Flexem FE6400CE provides one 10/100M adaptive RJ45 Ethernet port plus COM1 RS232/RS485/RS422, COM2 RS485, and COM3 RS232 serial ports.
How is the display protected in a washdown-adjacent area?
The front face reaches IP65 when the Flexem FE6400CE is flush-panel mounted, while the rear enclosure is rated IP20.
How does the power design support mission-critical uptime?
Voltage stability is a common failure point in oil and gas facilities, where long DC runs and motor starts can drag the supply. This unit accepts DC 9 to 28 V, so it keeps running through brownouts that would reset a narrower-input terminal. Power interruption tolerance is under 5 ms maximum, and the supply path includes lightning and surge protection.
EMC performance is documented to EN61000-6-2:2019 and EN61000-6-4:2019, with RoHS compliance. Surge immunity is ±1kV, EFT immunity is ±2kV, and ESD immunity is 4kV contact and 8kV air. Those figures let reliability engineers judge the unit against site electrical-noise profiles before committing to a panel build.

Which interfaces simplify integration and hmi replacement parts planning?
Built-in ports include one Type-C 2.0 USB Slave and one USB Type A 2.0 USB Host. Programs download over USB Slave, a U-disk, or Ethernet, and the FStudio software handles project development. An FLink2 pluggable IIoT module slot provides a path for communication expansion when a project scope grows.
Because the unit has no built-in discrete I/O, it works as an operating terminal alongside existing controllers. For industrial ethernet switch replacement projects, the single 10/100M adaptive RJ45 port connects the HMI to the plant network. Integration Note: wiring into plant networks may require an external gateway or connection module; confirm cables and gateways with the supplier before commissioning.
What installation details should a panel builder confirm?
The panel cutout measures 260×202 mm, and the enclosure is black engineering plastic. Overall dimensions are 213×273×36 mm, and the unit weighs approximately 0.920 kg. Front IP65 protection depends on a flush panel mount, so gasket seating and cutout flatness deserve attention during fabrication.
Confirm that the cabinet supply stays within DC 9 to 28 V under load, and allow for the <10W maximum consumption when sizing the DC branch. Keep ambient temperature inside the 0 to 50 °C operating window, particularly in sun-exposed enclosures.
How should maintenance teams plan for long service?
The LED backlight and 50,000-hour LCD lifetime set the expected display service window. Periodic inspection should cover the front gasket, the touch panel surface, and the power terminals. In dusty compressor areas, verify that the flush mount still seals to IP65 and that rear ventilation remains unobstructed.
Because this unit is part of the current Flexem product line, spares planning can follow normal asset-management cycles. Contact PetroPartsOnline for parts suited to your application's requirements, including application-specific selection guidance for hmi touchscreen replacement work.
Frequently asked questions
What supply voltage does this unit require?
The Flexem this unit runs from DC 24V nominal with an input range of DC 9 to 28 V, and maximum power consumption is under 10W.
Is this unit a practical hmi touchscreen replacement for existing panels?
With a 260×202 mm panel cutout and 213×273×36 mm overall dimensions, the Flexem this unit can be evaluated against the existing panel opening before any fabrication work begins.
What operating temperature range does this HMI support?
The Flexem this unit is rated for 0 to 50 °C operating temperature and -20 to 60 °C storage temperature, with 10 to 90% RH non-condensing humidity.
Does this unit include serial and Ethernet ports?
Yes. The Flexem this unit provides one 10/100M adaptive RJ45 Ethernet port plus COM1 RS232/RS485/RS422, COM2 RS485, and COM3 RS232 serial ports.
How is the display protected in a washdown-adjacent area?
The front face reaches IP65 when the Flexem this unit is flush-panel mounted, while the rear enclosure is rated IP20.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "FE6400CE | Flexem 10.1" HMI Touchscreen Replacement", "mpn": "FE6400CE", "sku": "FE6400CE", "brand": {"@type": "Brand", "name": "Flexem"}, "description": "When a legacy panel display fails on a gas-compressor skid, engineers need a drop-in terminal that tolerates voltage sag and shop-floor heat without a redesign. The Flexem FE6400CE answers that challenge: a 10.1-inch wide-viewing-angle resistive-touch HMI with built-in Ethernet, a 1GHz dual-core ARM Cortex-A7 CPU, and a DC 24V supply that accepts DC 9 to 28 V. It is a field-proven candidate for hmi touchscreen replacement projects where the panel cutout is already fixed at 260×202 mm. What makes", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1793939455-FE6400CE_1__fp5d024e00.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793939463-FE6400CE_2__fp337f6f8d.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793939470-FE6400CE_3__fpa37f4ed4.jpg"], "category": "HMI & Operator Interface"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "Is the FE6400CE a practical hmi touchscreen replacement for existing panels?", "acceptedAnswer": {"@type": "Answer", "text": "With a 260×202 mm panel cutout and 213×273×36 mm overall dimensions, the Flexem FE6400CE can be evaluated against the existing panel opening before any fabrication work begins."}}, {"@type": "Question", "name": "What operating temperature range does this HMI support?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem FE6400CE is rated for 0 to 50 °C operating temperature and -20 to 60 °C storage temperature, with 10 to 90% RH non-condensing humidity."}}, {"@type": "Question", "name": "Does the FE6400CE include serial and Ethernet ports?", "acceptedAnswer": {"@type": "Answer", "text": "Yes. The Flexem FE6400CE provides one 10/100M adaptive RJ45 Ethernet port plus COM1 RS232/RS485/RS422, COM2 RS485, and COM3 RS232 serial ports."}}, {"@type": "Question", "name": "How is the display protected in a washdown-adjacent area?", "acceptedAnswer": {"@type": "Answer", "text": "The front face reaches IP65 when the Flexem FE6400CE is flush-panel mounted, while the rear enclosure is rated IP20."}}, {"@type": "Question", "name": "How does the power design support mission-critical uptime?", "acceptedAnswer": {"@type": "Answer", "text": "Voltage stability is a common failure point in oil and gas facilities, where long DC runs and motor starts can drag the supply. This unit accepts DC 9 to 28 V, so it keeps running through brownouts that would reset a narrower-input terminal. Power interruption tolerance is under 5 ms maximum, and the supply path includes lightning and surge protection. EMC performance is documented to EN61000-6-2:2019 and EN61000-6-4:2019, with RoHS compliance. Surge immunity is ±1kV, EFT immunity is ±2kV, and ESD immunity is 4kV contact and 8kV air. Those figures let reliability engineers judge the unit against site electrical-noise profiles before committing to a panel build. Which interfaces simplify integration and hmi replacement parts planning? Built-in ports include one Type-C 2.0 USB Slave and one USB Type A 2.0 USB Host. Programs download over USB Slave, a U-disk, or Ethernet, and the FStudio software handles project development. An FLink2 pluggable IIoT module slot provides a path for communication expansion when a project scope grows. Because the unit has no built-in discrete I/O, it works as an operating terminal alongside existing controllers. For industrial ethernet switch replacement projects, the single 10/100M adaptive RJ45 port connects the HMI to the plant network. Integration Note: wiring into plant networks may require an external gateway or connection module; confirm cables and gateways with the supplier before commissioning. What installation details should a panel builder confirm? The panel cutout measures 260×202 mm, and the enclosure is black engineering plastic. Overall dimensions are 213×273×36 mm, and the unit weighs approximately 0.920 kg. Front IP65 protection depends on a flush panel mount, so gasket seating and cutout flatness deserve attention during fabrication. Confirm that the cabinet supply stays within DC 9 to 28 V under load, and allow for the <10W maximum consumption when sizing the DC branch. Keep ambient temperature inside the 0 to 50 °C operating window, particularly in sun-exposed enclosures. How should maintenance teams plan for long service? The LED backlight and 50,000-hour LCD lifetime set the expected display service window. Periodic inspection should cover the front gasket, the touch panel surface, and the power terminals. In dusty compressor areas, verify that the flush mount still seals to IP65 and that rear ventilation remains unobstructed. Because this unit is part of the current Flexem product line, spares planning can follow normal asset-management cycles. Contact PetroPartsOnline for parts suited to your application's requirements, including application-specific selection guidance for hmi touchscreen replacement work. Frequently asked questions What supply voltage does this unit require? The Flexem this unit runs from DC 24V nominal with an input range of DC 9 to 28 V, and maximum power consumption is under 10W. Is this unit a practical hmi touchscreen replacement for existing panels? With a 260×202 mm panel cutout and 213×273×36 mm overall dimensions, the Flexem this unit can be evaluated against the existing panel opening before any fabrication work begins. What operating temperature range does this HMI support? The Flexem this unit is rated for 0 to 50 °C operating temperature and -20 to 60 °C storage temperature, with 10 to 90% RH non-condensing humidity. Does this unit include serial and Ethernet ports? Yes. The Flexem this unit provides one 10/100M adaptive RJ45 Ethernet port plus COM1 RS232/RS485/RS422, COM2 RS485, and COM3 RS232 serial ports. How is the display protected in a washdown-adjacent area? The front face reaches IP65 when the Flexem this unit is flush-panel mounted, while the rear enclosure is rated IP20."}}]}]}