FC5M-40MN-AC | Flexem 24DI/16DO PLC AC 220V





Introduction:
The Flexem FC5M-40MN-AC is a programmable controller with 24 discrete inputs and 16 transistor outputs, rated for AC 220V supply and operation from -10°C to 60°C.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Flexem FC5M-40MN-AC is a industrial automation component for industrial control and automation applications.
Flexem FC5M-40MN-AC: A Rugged PLC for Demanding Environments
The Flexem this unit is a programmable controller from the FC5 series, engineered for reliability in harsh oil and gas applications. It combines 24 discrete inputs (7 fast) and 16 transistor outputs (6 fast) with a 220V AC power supply, making it a dependable choice for mission-critical control tasks.
Built for demanding environments, this controller operates reliably across a wide temperature range and offers robust isolation and protection features. Its flexible I/O configuration and high-speed capabilities suit applications requiring precise control and monitoring.

Key Features and Technical Specifications
- Power supply: Rated AC 220V, ensuring compatibility with standard industrial power systems.
- Discrete inputs: 24 inputs, 7 of which are high-speed, supporting NPN/PNP sensors.
- Discrete outputs: 16 transistor outputs (NPN), 6 high-speed, with 5–30V DC range and 2A per point.
- Operating temperature: -10°C to 60°C, suitable for challenging field conditions.
- High-speed inputs: Up to 200kHz for single-phase or pulse/direction counting.
- High-speed outputs: PTO up to 200kHz, PWM up to 50kHz with 0.5% duty cycle resolution.
- Isolation: Optical isolation on inputs; 500V AC isolation between outputs and internal logic.
- Protection: Short-circuit protection with self-recovery every 10ms; overvoltage protection up to 30V.
- Environmental: IP20 rating, pollution degree 2, operating altitude up to 3,000m.
- Coating: Protective coating with dry film thickness ≥20μm (enhanced version ≥40μm).
These specifications ensure this unit delivers reliable performance in oil and gas environments where temperature extremes and electrical noise are common.
Applications in Oil and Gas Automation
With its robust I/O count and high-speed capabilities, this unit is well-suited for applications such as pump control, valve monitoring, and safety shutdown systems. The 24 inputs can interface with limit switches, proximity sensors, and flow meters, while the 16 outputs can drive relays, solenoids, and indicator lights. In remote wellhead sites, the wide operating temperature range and protective coating help resist temperature fluctuations and contaminants. The high-speed inputs and outputs enable precise control of variable frequency drives and stepper motors, enhancing process efficiency. For mission-critical operations, the short-circuit protection and optical isolation contribute to system uptime and safety.

Installation and Setup Guidance
Mount the controller in a protective enclosure that maintains the specified operating temperature range. Use shielded cables for high-speed inputs and outputs, with cable lengths not exceeding 5m for high-speed signals and 100m for standard shielded inputs. The removable terminal blocks simplify wiring and maintenance. Ensure the power supply is within the rated AC 220V and that wiring complies with local electrical codes. For discrete outputs, verify that the load current does not exceed 2A per point and 4A per group. The controller's IP20 rating requires installation in a clean, dry environment; avoid exposure to conductive dust or moisture.
Maintenance and Reliability
Regular inspection of terminal connections and cable integrity is recommended to maintain reliable operation. This unit features short-circuit protection with automatic recovery, reducing downtime from wiring faults. The protective coating helps resist corrosion in humid or contaminated atmospheres. In oil and gas installations, periodic checks of the enclosure's sealing and cleaning of ventilation paths can prolong service life. The wide storage temperature range (-20°C to 70°C) allows for safe storage in unheated warehouses. With no derating required for resistive loads, the outputs can handle full load continuously, contributing to consistent performance.
Compatibility and Integration
this unit supports NPN and PNP sensor types on its inputs, providing flexibility in sensor selection. The high-speed inputs and outputs are compatible with encoders and stepper drives, enabling motion control applications. The controller can be integrated into existing control systems via its discrete I/O; however, for network connectivity, additional communication modules may be required. When integrating into fieldbus networks, consult PetroPartsOnline to confirm compatibility and cabling requirements.
Frequently Asked Questions
What is the operating temperature range of this unit?
The Flexem this unit operates within a temperature range of -10°C to 60°C, making it suitable for many industrial environments.
Can this unit handle high-speed counting applications?
Yes, the Flexem this unit features high-speed inputs that support up to 200kHz for single-phase or pulse/direction counting, ideal for encoder feedback.
What type of power supply does this unit require?
The Flexem this unit requires an AC 220V power supply, which is standard in many industrial settings.
Are the outputs of this unit protected against short circuits?
Yes, the Flexem this unit includes short-circuit protection with self-recovery every 10ms, enhancing system reliability.
What is the maximum output current per point on this unit?
The Flexem this unit provides a maximum output current of 2A per point and 4A per group, sufficient for driving various industrial loads.
For parts suited to your application's requirements, contact PetroPartsOnline. Our team can provide application-specific selection guidance and reliable sourcing for critical operations.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "FC5M-40MN-AC | Flexem 24DI/16DO PLC AC 220V", "mpn": "FC5M-40MN-AC", "sku": "FC5M-40MN-AC", "brand": {"@type": "Brand", "name": "Flexem"}, "description": "The Flexem FC5M-40MN-AC is a industrial automation component for industrial control and automation applications. Flexem FC5M-40MN-AC: A Rugged PLC for Demanding Environments The Flexem this unit is a programmable controller from the FC5 series, engineered for reliability in harsh oil and gas applications. It combines 24 discrete inputs (7 fast) and 16 transistor outputs (6 fast) with a 220V AC power supply, making it a dependable choice for mission-critical control tasks. Built for demanding env", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938861-FC5M-40MN-AC_1__fpb34065f7.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938866-FC5M-40MN-AC_2__fp6b044a00.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938873-FC5M-40MN-AC_3__fpcbd31d33.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938878-FC5M-40MN-AC_4__fp492d1d76.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938884-FC5M-40MN-AC_5__fpbc5a7880.jpg"], "category": "Power Supplies"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the operating temperature range of this unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem this unit operates within a temperature range of -10°C to 60°C, making it suitable for many industrial environments."}}, {"@type": "Question", "name": "Can this unit handle high-speed counting applications?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Flexem this unit features high-speed inputs that support up to 200kHz for single-phase or pulse/direction counting, ideal for encoder feedback."}}, {"@type": "Question", "name": "What type of power supply does this unit require?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem this unit requires an AC 220V power supply, which is standard in many industrial settings."}}, {"@type": "Question", "name": "Are the outputs of this unit protected against short circuits?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Flexem this unit includes short-circuit protection with self-recovery every 10ms, enhancing system reliability."}}, {"@type": "Question", "name": "What is the maximum output current per point on this unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem this unit provides a maximum output current of 2A per point and 4A per group, sufficient for driving various industrial loads. For parts suited to your application's requirements, contact PetroPartsOnline. Our team can provide application-specific selection guidance and reliable sourcing for critical operations."}}]}]}