+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

FC5-40MR-DC | Flexem 24V DC 40 I/O Logic Controller

Introduction:

The Flexem FC5-40MR-DC is a 24V DC logic controller with 40 I/O points, relay outputs, and dual serial ports for rugged oil and gas control panels.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Flexem
Part Number: FC5-40MR-DC
Type: DC24V power supply
Condition: Subject to stock check
Shipping Port: Xiamen

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

The Flexem FC5-40MR-DC is a DC24V power supply for industrial control and automation applications.

What Is the Flexem FC5-40MR-DC?

The Flexem this power supply is a basic logic control unit powered by a 24V DC supply. It provides 40 built-in I/O points, combining 24 input points with 16 relay output points. This controller suits panel builders and maintenance teams who need dependable discrete control in demanding oil and gas environments.

Its 24V DC power supply type matches common field control voltages. The unit also includes two serial communication ports, one Ethernet port, and support for two expansion boards. These features make it a practical choice for mission-critical skids, pump controls, and safety-related monitoring panels.

Figure 1: Front view of the Flexem FC5-40MR-DC DC24V power supply showing its physical design and enclosure.

Key Specifications and I/O Capacity

  • Power supply type: 24V DC
  • Built-in I/O: 40 points total
  • Input points: 24
  • Output points: 16 relay outputs
  • Expansion boards: 2
  • Expansion ability: IO expansion modules, depending on CPU power supply, maximum 31
  • Ethernet port: 1 RJ45, 10/100M, self-adaptive
  • Serial ports: Port 1 RS485/232, Port 2 RS485, baud rate 4800–115200 bps
  • Modbus communication: 2 channels (1 DB9, 1 terminal block)
  • USB port: Type-C for program download, upload, online monitoring, and firmware upgrading
  • Real-time clock: Built-in, battery-backed, accuracy ±3s/day, one-year power outage protection

The 24V DC supply is a key parameter for oil and gas panels, where DC control power is common. Relay outputs provide dry contacts for direct switching of valves, alarms, and small motor starters. The 40 I/O points give enough capacity for many small to medium control tasks without immediate expansion.

How Does this power supply Support Oil and Gas Applications?

Field engineers often need a compact controller that can handle discrete signals and communicate with supervisory systems. This power supply offers two serial ports and one Ethernet port for this purpose. For example, a wellhead control panel might use the 24 inputs for pressure switches and level sensors, while the 16 relay outputs drive solenoid valves and alarm beacons.

The built-in real-time clock helps time-stamp events, which is useful for maintenance logs and sequence-of-events recording. With a one-year power outage protection, the clock retains time during shutdowns. The two expansion boards allow adding analog or digital modules as the process grows, and the IO expansion bus can support up to 31 modules depending on CPU power supply.

Because the unit is powered by 24V DC, it can share the same DC bus as other field devices. This simplifies wiring and reduces the need for separate AC supplies in remote locations. The relay outputs are suitable for switching both AC and DC loads, giving panel designers flexibility when selecting final control elements.

Figure 2: Technical layout and connection details for the Flexem FC5-40MR-DC DC24V power supply.

Communication and Integration Notes

The controller provides two Modbus communication channels: one DB9 port and one terminal block. These can connect to Modbus RTU devices such as variable frequency drives, remote I/O, or flow computers. The RS485/232 serial ports support baud rates from 4800 to 115200 bps, allowing adaptation to different network speeds.

The Ethernet port is 10/100M self-adaptive, which can link the controller to an HMI or a plant network. For Modbus TCP or other Ethernet-based protocols, confirm compatibility with the Flexem programming environment. When wiring into a fieldbus network, you may need an external gateway or connection module; verify cable and gateway requirements with PetroPartsOnline before installation.

The USB Type-C port is used for program download and upload, online monitoring, and firmware upgrading. This port simplifies commissioning and troubleshooting in the field, as technicians can connect a laptop directly without additional adapters.

Installation and Maintenance Guidance

Mount the unit in a control panel that protects it from direct exposure to moisture, dust, and vibration. Use the 24V DC supply within the specified voltage range and provide proper grounding. Because the relay outputs are electromechanical, ensure that the load current and voltage do not exceed the contact ratings. Refer to the official datasheet for exact relay contact ratings and wiring diagrams.

For reliable operation, inspect the controller periodically for loose connections and accumulated dust. The real-time clock battery should be checked during routine maintenance; the one-year power outage protection means the battery may need replacement after extended service. Follow the manufacturer's safety manual for all maintenance activities.

When selecting expansion modules, consider the CPU power supply budget. The maximum of 31 expansion modules depends on the power available from the CPU. Plan the I/O count and power consumption before adding modules to avoid overloading the supply.

Frequently Asked Questions

What is the power supply requirement for the Flexem this power supply?

The Flexem this power supply requires a 24V DC power supply. This matches the DC control voltage commonly found in oil and gas panels, allowing the controller to share the same power bus as other field devices.

How many I/O points does this power supply provide?

this power supply provides 40 built-in I/O points, consisting of 24 input points and 16 relay output points. This capacity supports discrete control tasks such as valve actuation, alarm signaling, and pump monitoring.

Can this power supply be expanded with additional modules?

Yes, this power supply supports two expansion boards and IO expansion modules. The maximum number of expansion modules is 31, depending on the CPU power supply. Verify the power budget before adding modules.

What communication ports are available on this power supply?

this power supply includes one RJ45 Ethernet port (10/100M, self-adaptive), two serial ports (Port 1 RS485/232, Port 2 RS485), and two Modbus channels (1 DB9, 1 terminal block). A USB Type-C port is provided for programming and monitoring.

Does this power supply have a real-time clock?

Yes, this power supply includes a built-in real-time clock with battery backup. It offers accuracy of ±3s/day and one-year power outage protection, which helps maintain time-stamped event logs during shutdowns.

Contact PetroPartsOnline for parts suited to your application's requirements.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]