EVF8222-E | Lenze 22 kW 8200 Frequency Inverter



Introduction:
The Lenze EVF8222-E is a 22 kW three-phase frequency inverter from the 8200 series, built for standard drive tasks with 150% overload capacity for 60 seconds.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Lenze EVF8222-E is a Frequency inverter for industrial control and automation applications.
Lenze EVF8222-E: A Field-Proven Drive for Standard Applications
Industry has moved from fixed-speed motors to controlled drives that match torque to the load. The Lenze this drive belongs to that evolution: a three-phase frequency inverter from the 8200 series, rated 22.0 kW for a 4-pole asynchronous motor at 3 AC 400 V. It delivers 47.0 A nominal output current at 8 kHz chopper frequency and 32.6 kVA nominal output power.
Engineers working on pumps, fans and conveyors often need a dependable drive that handles short overloads without tripping. This model provides 150% rated output current for 60 s, with a maximum output current of 70.5 A for 60 s. The result is a rugged unit for mission-critical processes where starting torque and transient loads are normal.

How Does this drive Handle Harsh Electrical Conditions?
The supply voltage range is 3/PE AC 320 to 528 V nominal at 45 to 65 Hz, with an alternative DC supply of 460 to 740 V DC. That wide window helps the drive ride through grid variations common in oil and gas facilities. Power loss is 640 W, which matters when sizing enclosures and cooling.
For motor control, the inverter offers V/f characteristic control with auto boost or selectable Flux Torque Control (FTC). These modes let commissioning engineers match the drive to standard loads or to applications needing tighter current control. Chopper frequency is adjustable to 4, 8, 12 or 16 kHz, so acoustic noise and motor heating can be balanced on site.
Key Technical Specifications
- Rated motor power: 22.0 kW for a 4-pole asynchronous motor at 3 AC 400 V.
- Output current: 47.0 A nominal at 8 kHz chopper frequency.
- Maximum output current: 70.5 A for 60 s.
- Overload capacity: 150% rated output current for 60 s.
- Output power: 32.6 kVA nominal.
- Supply voltage: 3/PE AC 320 to 528 V nominal, 45 to 65 Hz; alternative DC supply 460 to 740 V DC.
- Operating temperature: 0 to +40 °C; +40 to +50 °C with power derating 2.5% per K.
- Storage temperature: -25 to +55 °C.
- Relative humidity: average 85 % RH, without condensation (climatic class 3K3 per EN 50178).
- Protection rating: IP20.
- Dimensions (H×W×D): 350 × 250 × 250 mm.
- Weight: 12.5 kg.

Where Does This Inverter Fit in Oil & Gas Operations?
Because this drive is built for demanding environments, it suits standard drive tasks in upstream and midstream facilities. Typical uses include pump drives on transfer skids, fan motors in cooling banks and conveyor systems in material handling. The 150% overload for 60 s helps when a pump starts against a full line or a fan has to overcome inertia.
In remote locations, the wide input voltage range reduces sensitivity to generator or grid fluctuations. Meanwhile, the IP20 rating means the unit should be installed in a suitable enclosure, which is standard practice for cabinet-mounted drives. For projects requiring reliable sourcing for critical operations, keeping a spare inverter on hand can shorten unplanned downtime.
Integration and Communication Options
The drive includes control terminals X1/X2 for setpoint and digital signals, plus a slot for an attachable communication module. No fieldbus is integrated as standard; pluggable host communication modules such as LECOM or bus modules are available per official product information. When wiring into a plant network, an external gateway or connection module may be required. Confirm cable and gateway compatibility with the supplier before commissioning.
Installation follows typical cabinet-drive practice: mount the 12.5 kg unit on a stable backplate, respect clearance for airflow and connect supply, motor and control wiring per the datasheet. Because the drive dissipates 640 W, ensure the enclosure ventilation or cooling matches that load. During setup, select V/f or FTC mode and set the chopper frequency to suit motor insulation and noise limits.
Maintenance and Long-Term Reliability
Periodic inspection should focus on cooling paths, terminal tightness and dust buildup on heatsinks. In oil and gas plants, ambient temperature often approaches the upper limit; above +40 °C the drive requires 2.5% derating per K, so monitor cabinet conditions. The storage range of -25 to +55 °C allows spare units to be kept in uncontrolled warehouses without condensation risk.
Please note that official Lenze product information lists this order code as superseded by newer drive generations. For replacement or upgrade planning, contact PetroPartsOnline to confirm current lifecycle status and availability before ordering. Their team can also provide application-specific selection guidance for drives suited to your process conditions.
Frequently Asked Questions
What is the supply voltage range of the Lenze EVF8222-E?
The Lenze EVF8222-E accepts 3/PE AC 320 to 528 V nominal at 45 to 65 Hz, with an alternative DC supply of 460 to 740 V DC.
How much overload can the EVF8222-E handle?
The Lenze EVF8222-E provides 150% rated output current for 60 s, with a maximum output current of 70.5 A for 60 s.
Does the EVF8222-E include a built-in fieldbus?
No, the Lenze EVF8222-E has control terminals X1/X2 and a slot for an attachable communication module, but no integrated fieldbus as standard.
What is the operating temperature range of the EVF8222-E?
The Lenze EVF8222-E operates from 0 to +40 °C, and up to +50 °C with a power derating of 2.5% per K.
Is the EVF8222-E still available?
Official Lenze product information lists this order code as superseded by newer drive generations. Contact PetroPartsOnline to verify current lifecycle status and availability.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "EVF8222-E | Lenze 22 kW 8200 Frequency Inverter", "mpn": "EVF8222-E", "sku": "EVF8222-E", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "The Lenze EVF8222-E is a Frequency inverter for industrial control and automation applications. Lenze EVF8222-E: A Field-Proven Drive for Standard Applications Industry has moved from fixed-speed motors to controlled drives that match torque to the load. The Lenze this drive belongs to that evolution: a three-phase frequency inverter from the 8200 series, rated 22.0 kW for a 4-pole asynchronous motor at 3 AC 400 V. It delivers 47.0 A nominal output current at 8 kHz chopper frequency and 32.6 kVA", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794063382-EVF8222-E_1__fpd68000bc.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794063388-EVF8222-E_2__fp1a1e522b.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794063396-EVF8222-E_3__fpe6862a0e.jpg"], "category": "Drives & Motion Control"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the supply voltage range of the Lenze EVF8222-E?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze EVF8222-E accepts 3/PE AC 320 to 528 V nominal at 45 to 65 Hz, with an alternative DC supply of 460 to 740 V DC."}}, {"@type": "Question", "name": "How much overload can the EVF8222-E handle?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze EVF8222-E provides 150% rated output current for 60 s, with a maximum output current of 70.5 A for 60 s."}}, {"@type": "Question", "name": "Does the EVF8222-E include a built-in fieldbus?", "acceptedAnswer": {"@type": "Answer", "text": "No, the Lenze EVF8222-E has control terminals X1/X2 and a slot for an attachable communication module, but no integrated fieldbus as standard."}}, {"@type": "Question", "name": "What is the operating temperature range of the EVF8222-E?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze EVF8222-E operates from 0 to +40 °C, and up to +50 °C with a power derating of 2.5% per K."}}, {"@type": "Question", "name": "Is the EVF8222-E still available?", "acceptedAnswer": {"@type": "Answer", "text": "Official Lenze product information lists this order code as superseded by newer drive generations. Contact PetroPartsOnline to verify current lifecycle status and availability."}}]}]}