+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

E94AMHE0094 | Lenze 4 kW CANopen Drive Axis Module

Introduction:

Lenze E94AMHE0094 is a 4 kW drive axis module for DC-bus cabinet mounting, built for demanding oil and gas drive applications with CANopen on board.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Lenze
Part Number: E94AMHE0094
Type: Drive axis module
Condition: Subject to stock check
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Lenze E94AMHE0094 is a drive axis module from the Servo Drives 9400 HighLine Multi Drive series, rated for 4 kW nominal motor power with an 11.6 A nominal output current at 4 kHz switching frequency. It mounts in a DC-bus cabinet and connects to a DC 260 V to 775 V supply, making it a rugged building block for mission-critical drive trains in oil and gas duty.

Why this module suits demanding drive cabinets

Engineers specifying this module get a compact axis rated for continuous industrial service. The 4 kW rating pairs with a 15.4 A nominal DC-bus current, so the module can sit alongside other drives on a shared DC bus without extra conversion stages. A 3× overload factor and 28 A maximum short-term output current give headroom for the high-torque starts that pumps, compressors and winches demand. Because the module is built for demanding environments, it keeps its ratings across a wide DC input window rather than requiring a tightly regulated feed.

Figure 1: Front view of the Lenze E94AMHE0094 Drive axis module showing its physical design and enclosure.

Key specifications at a glance

  • Rated motor power: 4 kW nominal (ASM 4-pole, 400 V class)
  • Rated output current: 11.6 A nominal at 4 kHz switching frequency
  • Max. output current: 17.4 A maximum
  • Max. short-term output current: 28 A maximum short-term
  • Overload factor: 3
  • Rated DC-bus current: 15.4 A nominal
  • Supply voltage: DC 260 V -0 % … 775 V +0 % (DC-bus operation)
  • Power loss: 230 W
  • Operating temperature: -10 °C … +55 °C (EN 60721-3-3 class 3K3; derate rated output current by 2.5 %/°C above +45 °C)
  • Storage temperature: -25 °C … +60 °C (EN 60721-3-1 class 1K3)
  • Site altitude: up to 4000 m AMSL; derate rated output current by 5 % per 1000 m above 1000 m
  • Protection rating: IP20 (EN 60529); NEMA 250 type 1
  • Dimensions (H×W×D): 350 mm (with 507 installation backplane) × 90 mm × 288 mm
  • Weight: 5.3 kg

How does the DC-bus input voltage affect installation?

The module accepts a DC-bus supply from 260 V to 775 V, so it tolerates normal bus ripple without tripping. During cabinet design, confirm that the shared bus stays inside that window under all load steps. Because the input is a DC bus rather than a direct AC feed, the axis relies on the cabinet's existing rectifier and bus capacitors. This arrangement reduces wiring inside the enclosure and keeps the footprint small. For projects with unusual bus configurations, contact PetroPartsOnline for parts suited to your application's requirements.

Figure 2: Technical layout and connection details for the Lenze E94AMHE0094 Drive axis module.

Thermal planning and operating temperature

Continuous operation is rated from -10 °C to +55 °C under climatic class 3K3. Above +45 °C, derate the rated output current by 2.5 % per °C, which matters in hot desert or process-area cabinets. At altitude, derate by 5 % per 1000 m above 1000 m up to 4000 m AMSL. Planning these margins early avoids nuisance over-temperature faults later. The 230 W power loss figure helps size cabinet cooling, and the IP20 rating means the module belongs inside a protected enclosure rather than on an open skid.

Communication and integration

CANopen is available on board, giving a field-proven network path for drive control and diagnostics. A diagnostic interface is reachable through the E94AZCUS USB adapter. Two extension slots accept communication or extension modules from the E94AYC family, and one memory slot plus one safety slot are provided. When wiring into a CANopen network, confirm cable routing and termination with the supplier; integration may require an external gateway or connection module depending on the controller. PetroPartsOnline can advise on the accessories that match your application.

Maintenance and reliability in the field

Inspect cabinet filters and airflow paths on a scheduled basis, because the module depends on forced or convective cooling inside the enclosure. Check bus connections for tightness during planned shutdowns, and review fault logs through the diagnostic interface to catch trends early. The wide storage range of -25 °C … +60 °C and transport range of -25 °C … +70 °C support spare-part stock in varied climates. Vibration resistance to class 2M2 covers transport and operation, which supports reliability you can depend on in skid-mounted and rotating-equipment areas.

Frequently asked questions

What is the supply voltage range of this module?

The Lenze this module operates from a DC-bus supply of 260 V to 775 V, with the stated tolerance of -0 % to +0 % on that window.

Which protocol does this Lenze module support?

CANopen is available on board the Lenze this module, and a diagnostic interface is accessible through the E94AZCUS USB adapter.

Can this module run at 55 °C ambient?

Yes, the Lenze this module is rated from -10 °C to +55 °C, but rated output current must be derated by 2.5 %/°C above +45 °C.

What overload capability does the drive axis module offer?

The Lenze this module has an overload factor of 3, with 17.4 A maximum output current and 28 A maximum short-term output current.

How much cabinet space does the module need?

The Lenze this module measures 350 mm high with the 507 installation backplane, 90 mm wide and 288 mm deep, and weighs 5.3 kg.

Frequently Asked Questions

What is the supply voltage range of the E94AMHE0094?

The Lenze E94AMHE0094 operates from a DC-bus supply of 260 V to 775 V, with the stated tolerance of -0 % to +0 % on that window.

Which protocol does this Lenze module support?

CANopen is available on board the Lenze E94AMHE0094, and a diagnostic interface is accessible through the E94AZCUS USB adapter.

Can the E94AMHE0094 run at 55 °C ambient?

Yes, the Lenze E94AMHE0094 is rated from -10 °C to +55 °C, but rated output current must be derated by 2.5 %/°C above +45 °C.

What overload capability does the drive axis module offer?

The Lenze E94AMHE0094 has an overload factor of 3, with 17.4 A maximum output current and 28 A maximum short-term output current.

How much cabinet space does the module need?

The Lenze E94AMHE0094 measures 350 mm high with the 507 installation backplane, 90 mm wide and 288 mm deep, and weighs 5.3 kg.

{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "E94AMHE0094 | Lenze 4 kW CANopen Drive Axis Module", "mpn": "E94AMHE0094", "sku": "E94AMHE0094", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "Lenze E94AMHE0094 is a drive axis module from the Servo Drives 9400 HighLine Multi Drive series, rated for 4 kW nominal motor power with an 11.6 A nominal output current at 4 kHz switching frequency. It mounts in a DC-bus cabinet and connects to a DC 260 V to 775 V supply, making it a rugged building block for mission-critical drive trains in oil and gas duty. Why this module suits demanding drive cabinets Engineers specifying this module get a compact axis rated for continuous industrial servic", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064801-E94AMHE0094_1__fp677950c0.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064808-E94AMHE0094_2__fpb6e362e9.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794064815-E94AMHE0094_3__fp036c36f5.jpg"], "category": "Drives & Motion Control"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What is the supply voltage range of the E94AMHE0094?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E94AMHE0094 operates from a DC-bus supply of 260 V to 775 V, with the stated tolerance of -0 % to +0 % on that window."}}, {"@type": "Question", "name": "Which protocol does this Lenze module support?", "acceptedAnswer": {"@type": "Answer", "text": "CANopen is available on board the Lenze E94AMHE0094, and a diagnostic interface is accessible through the E94AZCUS USB adapter."}}, {"@type": "Question", "name": "Can the E94AMHE0094 run at 55 °C ambient?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Lenze E94AMHE0094 is rated from -10 °C to +55 °C, but rated output current must be derated by 2.5 %/°C above +45 °C."}}, {"@type": "Question", "name": "What overload capability does the drive axis module offer?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E94AMHE0094 has an overload factor of 3, with 17.4 A maximum output current and 28 A maximum short-term output current."}}, {"@type": "Question", "name": "How much cabinet space does the module need?", "acceptedAnswer": {"@type": "Answer", "text": "The Lenze E94AMHE0094 measures 350 mm high with the 507 installation backplane, 90 mm wide and 288 mm deep, and weighs 5.3 kg."}}]}]}

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap