3500/33-01-01 Bently Nevada 16-Channel Relay Module | 5A SPDT

Introduction:

3500/33-01-01 is a Bently Nevada 3500/33 16-Channel Relay Module. It provides 16 independent SPDT relay outputs. Each relay has epoxy sealing and arc suppressors. The module suits standard and hazardous area systems. Ideal for machinery protection alarm outputs.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Bently Nevada
Series: 3500 Monitoring system
Part Number: 3500/33-01-01
Type: 3500/33 16-Channel Relay Module
Condition: In Stock
Origin: U.S.A
Weight: 1.1
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Contact Ratings for Hazardous Area Systems

Technical Specifications of Bently Nevada 3500/33-01-01

The Bently Nevada 3500/33 (Model 3500/33-01-01) delivers 16 relay channels. You can group these channels into four sets of four. Each group operates in Normally De-energized (ND) or Normally Energized (NE) mode.

Power and Front Panel Indicators

  • Power Consumption: Consumes only 5.8 Watts typically.

  • OK LED: Lights up when the 3500/33-01-01 works properly.

  • TX/RX LED: Flashes during communication with other 3500 rack modules.

  • CH Alarm LED: Lights up when a relay channel enters an alarm state.

Relay Specifications

The 3500/33-01-01 uses single-pole double-throw (SPDT) relays. Each relay has epoxy sealing for environmental protection. Arc suppressors rated at 250 Vrms come installed as standard.

FeatureSpecification
Relay TypeSPDT
Environmental SealingEpoxy-sealed
Arc Suppressor250 Vrms
Contact Life10,000 cycles
Min Switched Current100 mA @ 5 Vdc

Contact Ratings for Standard Systems (DC Resistive Load)

VoltageMax Switched PowerMax Switched Current
24 Vdc70 W5 A
48 Vdc10 W5 A
60 Vdc9 W5 A
125 VdcN/A5 A (Max Voltage)

Contact Ratings for Standard Systems (AC Resistive Load)

  • Max Switched Current: 5 A

  • Max Switched Power: 1200 VA

  • Max Switched Voltage: 250 Vac

(cNRTLus Class 1 Div 2)Contact Ratings for Hazardous Area Systems

For the 3500/33-01-01 with hazardous area approval (Option 01):

  • Min Switched Current: 100 mA @ 5 Vdc

  • Max Switched Current: 5 A

  • Max Switched Voltage: 30 Vdc

Low Current Relay Applications (Special Order)

The 3500/33 also supports low current configurations:

  • Min Switched Current: 1 mA @ 1 Vdc

  • Max Switched Current: 100 mA @ 48 Vdc

  • Gold-plated relay minimum: 1 mA

  • Maximum before damage (gold relays): 5 mA

Environmental Limits

  • Operating Temperature: -30°C to +65°C (-22°F to +149°F)

  • Storage Temperature: -40°C to +85°C (-40°F to +185°F)

  • Humidity: 95%, non-condensing

  • Hazardous Area Approval: cNRTLus (Class 1, Division 2)


Installation Guide for 3500/33-01-01

Follow these steps to install the Bently Nevada 3500/33-01-01. Always power off the 3500 rack before starting.

  1. Insert the main module into 1 full-height front slot of the 3500 rack.

  2. Insert the I/O module into 1 full-height rear slot.

  3. Connect your field wiring to the I/O module terminals.

  4. Configure each relay group for ND or NE operation using the switches.

  5. Power on the rack and verify the OK LED turns green.

  6. Test each channel by simulating an alarm condition.

Note: The 3500/33-01-01 requires both front and rear slots. Do not leave the rear slot empty.


Package Contents (3500/33-01-01)

  • 1 x Bently Nevada 3500/33 Main Relay Module (3500/33-01-01)

  • 1 x I/O Module for rear slot

  • 1 x Relay configuration label


Frequently Asked Questions (FAQ)

### 1. Can I mix ND and NE modes on the same 3500/33 module?

Yes. The 3500/33-01-01 has four groups of four channels. You set each group independently for ND or NE operation.

2. What is the contact life of each relay?

Each relay lasts 10,000 cycles at rated load. For longer life, use the low current configuration with gold-plated relays.

3. Does the 3500/33-01-01 work in hazardous areas?

Yes. Option 01 provides cNRTLus approval for Class 1, Division 2 hazardous locations. Contact ratings limit to 30 Vdc in this configuration.

4. What happens if I short the recorder output?

The 3500/33-01-01 does not have a recorder output. That feature belongs to monitor modules like the 3500/53 or 3500/77M.

5. Can I use this module with 125 Vdc loads?

Yes for standard systems. The 3500/33-01-01 supports 125 Vdc as max switched voltage. Check your load is resistive.


Why Choose This Bently Nevada 3500/33-01-01?

The 3500/33-01-01 gives you 16 reliable relay outputs in one slot. Its epoxy-sealed relays resist moisture and vibration. The hazardous area approval expands your installation options. Choose this Bently Nevada 3500/33 for alarm annunciation, trip logic, or equipment control.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: sales@ubestplc.com

Contact: Klaus

 

Scan the QR code

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap