F5-MD1600 | Flexem 16-Point Digital Input Module




Introduction:
The Flexem F5-MD1600 is a 16-point bipolar digital input module rated at 24 VDC with optical coupler isolation and a selectable 1 ms to 100 ms filter time.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Flexem F5-MD1600 is a Compatibility Compatible for industrial control and automation applications.
The Flexem F5-MD1600 is a 16-point bipolar digital input module rated at 24 VDC with optical coupler isolation. It accepts source/sinking input types and is compatible with 2-wire and 3-wire sensors, making it a dependable choice for demanding oil and gas control panels.
Key Features and Technical Specifications of this unit
This module is built for field-proven reliability in mission-critical environments. The following specifications are drawn directly from the manufacturer's data.
- Input Characteristics: 16-point bipolar configuration.
- Rated Voltage: 24 VDC.
- Input Range: 0~28.8V DC.
- Rated Current: 7mA.
- Voltage in State 1: 15~28.8V (greater than 15V).
- Voltage in State 0: 0~5V (less than 5V).
- Current in State 1: Greater than 2.5mA.
- Current in State 0: Less than 1.0mA.
- Isolation: Optical coupler.
- Input Impedance: 3.3KΩ.
- Filter Time: Default 1ms, with 16 equally divided levels selectable from unfiltered to 100ms.
- Input Type: Source/sinking.
- Compatibility: Compatible with 2/3 wire sensors.
- Cable Length and Type: Max 100m shielded cable, 50m unshielded cable.
- Protection (overvoltage): 30V maximum, limited to 1 hour per day frequency.
- Wiring Structure: Removable terminal block.
- Dimension: Dimension B.

What Makes this unit Suitable for Harsh Oil and Gas Environments?
this unit is engineered for rugged operation where reliability is paramount. Its optical coupler isolation protects sensitive control circuitry from electrical noise and transients common in oil and gas facilities. The wide input range of 0~28.8V DC accommodates the voltage fluctuations often seen in field power supplies, while the overvoltage protection clamps at 30V maximum, limited to 1 hour per day frequency. This ensures the module can withstand occasional surges without damage.
The selectable filter time is a critical feature for maintenance engineers. With 16 levels from unfiltered to 100ms, you can tune the input response to reject contact bounce or electrical interference. In a pump station or compressor shed, this adjustability reduces nuisance trips and extends service life. The removable terminal block simplifies wiring and replacement, cutting downtime during maintenance. For mission-critical operations, these details translate into fewer unexpected stoppages and more dependable process control.
How Does this unit Simplify Installation and Maintenance?
From a maintenance engineer's perspective, ease of service is as important as performance. This unit addresses this with a removable terminal block, allowing you to pre-wire harnesses and swap modules quickly. The input type is source/sinking, providing flexibility in wiring configurations without additional components. Compatibility with 2/3 wire sensors means you can connect a wide range of field devices directly, reducing the need for signal conditioners.
When routing cables, observe the specified maximum lengths: 100m for shielded cable and 50m for unshielded cable. This guidance helps maintain signal integrity and avoid false inputs. The optical coupler isolation further protects against ground loops and noise, which are common in large facilities. For periodic maintenance, inspect terminal connections for tightness and verify that the filter time setting matches the application's noise profile. Because the module is built for demanding environments, it requires minimal intervention beyond routine checks.

Integration with Control Systems
this unit is a digital input module designed to interface with industrial controllers. Its 16 bipolar inputs can accept signals from switches, proximity sensors, and other discrete devices. The source/sinking input type allows connection to both PNP and NPN sensors, though the exact wiring depends on your system's configuration. Always refer to the official Flexem documentation for wiring diagrams and configuration settings.
For reliable operation, ensure the input voltage stays within the 0~28.8V DC range. The module's state thresholds are clearly defined: a voltage above 15V registers as state 1, while below 5V registers as state 0. This hysteresis prevents oscillation when input signals are noisy. The default 1ms filter time is suitable for most applications, but in high-noise environments, you can select a longer filter time to stabilize readings. Keep in mind that the overvoltage protection is limited to 30V maximum and should not be exceeded for more than 1 hour per day.
Frequently Asked Questions
What is the input voltage range of the Flexem this unit?
The Flexem this unit has an input range of 0~28.8V DC, with a rated voltage of 24 VDC. It reliably detects state 1 at voltages above 15V and state 0 below 5V.
Can this unit work with both 2-wire and 3-wire sensors?
Yes, the Flexem this unit is compatible with 2/3 wire sensors. Its source/sinking input type provides flexibility for different sensor output configurations.
How does the selectable filter time benefit maintenance?
The filter time can be set to 16 equally divided levels from unfiltered to 100ms, with a default of 1ms. This allows you to reject noise and contact bounce, reducing false triggers and improving system reliability.
What is the maximum cable length for this unit?
The Flexem this unit supports a maximum of 100m for shielded cable and 50m for unshielded cable. Exceeding these lengths may compromise signal integrity.
Is this unit isolated from the backplane?
Yes, the Flexem this unit uses optical coupler isolation between inputs and internal circuitry, protecting against electrical noise and transients.
For parts suited to your application's requirements, contact PetroPartsOnline.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "F5-MD1600 | Flexem 16-Point Digital Input Module", "mpn": "F5-MD1600", "sku": "F5-MD1600", "brand": {"@type": "Brand", "name": "Flexem"}, "description": "The Flexem F5-MD1600 is a Compatibility Compatible for industrial control and automation applications. The Flexem F5-MD1600 is a 16-point bipolar digital input module rated at 24 VDC with optical coupler isolation. It accepts source/sinking input types and is compatible with 2-wire and 3-wire sensors, making it a dependable choice for demanding oil and gas control panels. Key Features and Technical Specifications of this unit This module is built for field-proven reliability in mission-critical ", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938083-F5-MD1600_1__fpe72452a2.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938089-F5-MD1600_2__fp17d20769.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938095-F5-MD1600_3__fp9f8320e4.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793938101-F5-MD1600_4__fpa61c5773.jpg"], "category": "I/O Modules"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What Makes this unit Suitable for Harsh Oil and Gas Environments?", "acceptedAnswer": {"@type": "Answer", "text": "this unit is engineered for rugged operation where reliability is paramount. Its optical coupler isolation protects sensitive control circuitry from electrical noise and transients common in oil and gas facilities. The wide input range of 0~28.8V DC accommodates the voltage fluctuations often seen in field power supplies, while the overvoltage protection clamps at 30V maximum, limited to 1 hour per day frequency. This ensures the module can withstand occasional surges without damage. The selectable filter time is a critical feature for maintenance engineers. With 16 levels from unfiltered to 100ms, you can tune the input response to reject contact bounce or electrical interference. In a pump station or compressor shed, this adjustability reduces nuisance trips and extends service life. The removable terminal block simplifies wiring and replacement, cutting downtime during maintenance. For mission-critical operations, these details translate into fewer unexpected stoppages and more dependable process control."}}, {"@type": "Question", "name": "How Does this unit Simplify Installation and Maintenance?", "acceptedAnswer": {"@type": "Answer", "text": "From a maintenance engineer's perspective, ease of service is as important as performance. This unit addresses this with a removable terminal block, allowing you to pre-wire harnesses and swap modules quickly. The input type is source/sinking, providing flexibility in wiring configurations without additional components. Compatibility with 2/3 wire sensors means you can connect a wide range of field devices directly, reducing the need for signal conditioners. When routing cables, observe the specified maximum lengths: 100m for shielded cable and 50m for unshielded cable. This guidance helps maintain signal integrity and avoid false inputs. The optical coupler isolation further protects against ground loops and noise, which are common in large facilities. For periodic maintenance, inspect terminal connections for tightness and verify that the filter time setting matches the application's noise profile. Because the module is built for demanding environments, it requires minimal intervention beyond routine checks."}}, {"@type": "Question", "name": "What is the input voltage range of the Flexem this unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem this unit has an input range of 0~28.8V DC, with a rated voltage of 24 VDC. It reliably detects state 1 at voltages above 15V and state 0 below 5V."}}, {"@type": "Question", "name": "Can this unit work with both 2-wire and 3-wire sensors?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Flexem this unit is compatible with 2/3 wire sensors. Its source/sinking input type provides flexibility for different sensor output configurations."}}, {"@type": "Question", "name": "How does the selectable filter time benefit maintenance?", "acceptedAnswer": {"@type": "Answer", "text": "The filter time can be set to 16 equally divided levels from unfiltered to 100ms, with a default of 1ms. This allows you to reject noise and contact bounce, reducing false triggers and improving system reliability."}}, {"@type": "Question", "name": "What is the maximum cable length for this unit?", "acceptedAnswer": {"@type": "Answer", "text": "The Flexem this unit supports a maximum of 100m for shielded cable and 50m for unshielded cable. Exceeding these lengths may compromise signal integrity."}}, {"@type": "Question", "name": "Is this unit isolated from the backplane?", "acceptedAnswer": {"@type": "Answer", "text": "Yes, the Flexem this unit uses optical coupler isolation between inputs and internal circuitry, protecting against electrical noise and transients. For parts suited to your application's requirements, contact PetroPartsOnline."}}]}]}
