+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

EMB9351-C | Lenze 270-775V DC Brake Module

Introduction:

Lenze EMB9351-C brake module handles 270-775V DC, 16A peak for one minute, and 100W continuous braking power for Series 9300 drives.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Lenze
Part Number: EMB9351-C
Type: Brake module
Condition: Subject to stock check
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

The Lenze EMB9351-C is a Brake module for industrial control and automation applications.

How Do You Manage Braking Energy in High-Voltage Drive Systems?

Excess regenerative energy can trip drives or damage components in oil and gas automation. The Lenze EMB9351-C brake module answers that challenge with a cold plate design rated for 270-775V DC supply and 16A peak current for one minute. It belongs to the Lenze Series 9300 product line.

This brake module dissipates braking energy through a cold plate, which supports thermal management in rugged, mission-critical installations. Engineers specifying this module get a field-proven component built for demanding environments.

Figure 1: Front view of the Lenze EMB9351-C Brake module showing its physical design and enclosure.

Key Specifications of the Lenze Brake Module

  • Supply Voltage: 270-775V DC
  • Threshold Ratings: 375/725/765V DC
  • Peak Current for 1 Minute: 16A DC
  • Continuous Braking Power: 100W
  • Ambient Operating Temperature: 0 to 40°C with no power reduction and -40 to 55°C with power reduction
  • Storage Temperature: -25 to 70°C
  • Protection Rating: IP10

The wide supply voltage range lets the module integrate into various DC bus systems. A 16A peak current for one minute provides headroom for short braking events, while 100W continuous braking power supports sustained operation. The threshold ratings of 375/725/765V DC define the voltage levels at which the module activates braking.

What Makes This Brake Module Suitable for Harsh Environments?

this module operates at ambient temperatures from 0 to 40°C without power reduction. Above 40°C up to 55°C, power reduction may be necessary to protect the module. This temperature behavior allows engineers to plan for derating in hot enclosures or outdoor cabinets. The storage temperature range of -25 to 70°C supports transport and standby in varied climates.

With an IP10 protection rating, the module is not dust-tight. It should be installed in areas where dust ingress is not a concern, such as inside a control cabinet with proper filtering. The cold plate construction aids heat dissipation, which is critical when braking energy is continuous.

Figure 2: Technical layout and connection details for the Lenze EMB9351-C Brake module.

Where Is this module Brake Module Used?

Oil and gas operations rely on adjustable-speed drives for pumps, compressors, and winches. When these loads decelerate, regenerative energy returns to the DC bus. This module manages that energy by switching a braking resistor, preventing overvoltage trips. Its 100W continuous braking power suits moderate duty cycles, while the 16A peak for one minute covers short, high-energy stops.

Because the supply voltage range reaches 775V DC, the module fits into higher-voltage drive systems common in heavy industry. The cold plate design helps maintain reliability in continuous operation. For mission-critical processes, this brake module offers a dependable way to handle braking energy without adding complex cooling infrastructure.

Installation and Integration Notes

Mount this module on a flat surface that can support its weight and provide adequate airflow. The cold plate should be kept free of obstructions. Connect the DC bus and braking resistor according to the drive manufacturer's instructions. Verify that the supply voltage stays within the 270-775V DC range during operation.

Because the module has an IP10 rating, install it inside an enclosure that limits dust. Ensure the ambient temperature stays within the specified range; if temperatures exceed 40°C, apply power reduction as needed. For systems requiring fieldbus communication, an external gateway or connection module may be needed; confirm cabling and gateway compatibility with the supplier.

Maintenance and Reliability

Inspect the brake module periodically for dust accumulation and loose connections. Check the cold plate for signs of overheating or blockage. Verify that the ambient temperature remains within the operating limits. The rugged construction supports long service life in demanding environments. Reliability you can depend on starts with proper installation and routine inspection.

Frequently Asked Questions

What is the supply voltage range of the Lenze this module?

The Lenze this module accepts a supply voltage of 270-775V DC, with threshold ratings of 375/725/765V DC.

Can this module handle peak currents?

Yes, the Lenze this module handles peak currents up to 16A DC for one minute.

What is the continuous braking power of this module?

The Lenze this module provides 100W of continuous braking power.

What are the operating temperature limits?

The module operates from 0 to 40°C without power reduction and from -40 to 55°C with power reduction.

Is this module suitable for dusty environments?

With an IP10 rating, the Lenze this module is not dust-tight and should be installed where dust ingress is not a concern.

For brake modules suited to your application's requirements, contact PetroPartsOnline.

{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "EMB9351-C | Lenze 270-775V DC Brake Module", "mpn": "EMB9351-C", "sku": "EMB9351-C", "brand": {"@type": "Brand", "name": "Lenze"}, "description": "The Lenze EMB9351-C is a Brake module for industrial control and automation applications. How Do You Manage Braking Energy in High-Voltage Drive Systems? Excess regenerative energy can trip drives or damage components in oil and gas automation. The Lenze EMB9351-C brake module answers that challenge with a cold plate design rated for 270-775V DC supply and 16A peak current for one minute. It belongs to the Lenze Series 9300 product line. This brake module dissipates braking energy through a cold", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1794062746-EMB9351-C_1__fpaeb4ab5a.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794062755-EMB9351-C_2__fpd75233bf.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1794062765-EMB9351-C_3__fpba47d7af.jpg"], "category": "Drives & Motion Control"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "How Do You Manage Braking Energy in High-Voltage Drive Systems?", "acceptedAnswer": {"@type": "Answer", "text": "Excess regenerative energy can trip drives or damage components in oil and gas automation. The Lenze EMB9351-C brake module answers that challenge with a cold plate design rated for 270-775V DC supply and 16A peak current for one minute. It belongs to the Lenze Series 9300 product line. This brake module dissipates braking energy through a cold plate, which supports thermal management in rugged, mission-critical installations. Engineers specifying this module get a field-proven component built for demanding environments. Key Specifications of the Lenze Brake Module Supply Voltage: 270-775V DC Threshold Ratings: 375/725/765V DC Peak Current for 1 Minute: 16A DC Continuous Braking Power: 100W Ambient Operating Temperature: 0 to 40°C with no power reduction and -40 to 55°C with power reduction Storage Temperature: -25 to 70°C Protection Rating: IP10 The wide supply voltage range lets the module integrate into various DC bus systems. A 16A peak current for one minute provides headroom for short braking events, while 100W continuous braking power supports sustained operation. The threshold ratings of 375/725/765V DC define the voltage levels at which the module activates braking. What Makes This Brake Module Suitable for Harsh Environments? this module operates at ambient temperatures from 0 to 40°C without power reduction. Above 40°C up to 55°C, power reduction may be necessary to protect the module. This temperature behavior allows engineers to plan for derating in hot enclosures or outdoor cabinets. The storage temperature range of -25 to 70°C supports transport and standby in varied climates. With an IP10 protection rating, the module is not dust-tight. It should be installed in areas where dust ingress is not a concern, such as inside a control cabinet with proper filtering. The cold plate construction aids heat dissipation, which is critical when braking energy is continuous. Where Is this module Brake Module Used? Oil and gas operations rely on adjustable-speed drives for pumps, compressors, and winches. When these loads decelerate, regenerative energy returns to the DC bus. This module manages that energy by switching a braking resistor, preventing overvoltage trips. Its 100W continuous braking power suits moderate duty cycles, while the 16A peak for one minute covers short, high-energy stops. Because the supply voltage range reaches 775V DC, the module fits into higher-voltage drive systems common in heavy industry. The cold plate design helps maintain reliability in continuous operation. For mission-critical processes, this brake module offers a dependable way to handle braking energy without adding complex cooling infrastructure. Installation and Integration Notes Mount this module on a flat surface that can support its weight and provide adequate airflow. The cold plate should be kept free of obstructions. Connect the DC bus and braking resistor according to the drive manufacturer's instructions. Verify that the supply voltage stays within the 270-775V DC range during operation. Because the module has an IP10 rating, install it inside an enclosure that limits dust. Ensure the ambient temperature stays within the specified range; if temperatures exceed 40°C, apply power reduction as needed. For systems requiring fieldbus communication, an external gateway or connection module may be needed; confirm cabling and gateway compatibility with the supplier. Maintenance and Reliability Inspect the brake module periodically for dust accumulation and loose connections. Check the cold plate for signs of overheating or blockage. Verify that the ambient temperature remains within the operating limits. The rugged construction supports long service life in demanding environments. Reliability you can depend on starts with proper installation and routine inspection. Frequently Asked Questions What is the supply voltage range of the Lenze this module? The Lenze this module accepts a supply voltage of 270-775V DC, with threshold ratings of 375/725/765V DC. Can this module handle peak currents? Yes, the Lenze this module handles peak currents up to 16A DC for one minute. What is the continuous braking power of this module? The Lenze this module provides 100W of continuous braking power. What are the operating temperature limits? The module operates from 0 to 40°C without power reduction and from -40 to 55°C with power reduction. Is this module suitable for dusty environments? With an IP10 rating, the Lenze this module is not dust-tight and should be installed where dust ingress is not a concern. For brake modules suited to your application's requirements, contact PetroPartsOnline."}}]}]}

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap