+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Allen-Bradley 1756-L84E ControlLogix Controller 20MB 128k I/O

Introduction:

High-performance ControlLogix controller with 20MB memory. Supports 128k discrete I/O and 4k analog I/O. 1GB Ethernet port. No battery required.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: ControlLogix 5580
Part Number: 1756-L84E
Type: ControlLogix Controller
Condition: In Stock
Origin: U.S.A
Weight: 0.39
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

Controller Design and Application

The Allen-Bradley 1756-L84E is a ControlLogix controller from the high-performance 5580 series. This advanced controller is tailor-made for large-scale manufacturing environments. It handles a staggering 128,000 discrete I/O points and 4,000 analog I/O points. Consequently, the 1756-L84E suits complex automation applications requiring massive I/O capacity. The controller fits into any 1756 chassis slot and occupies exactly one slot width.

Communication Capabilities

The 1756-L84E comes with integrated communication ports for flexible connectivity. The embedded Ethernet port supports 10/100/1000 Mbps transmission speeds. Therefore, it easily exchanges data with other controllers, HMIs, and SCADA systems on the same network. The USB 2.0 port provides 12 Mbps communication speed for programming and data transfer. Consequently, the controller supports local I/O control as well as distributed I/O architectures.

Network Protocol Support

This controller supports a wide range of industrial networks for maximum compatibility. For example, EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, and SynchLink are all supported. Third-party process and device networks are also compatible. Consequently, the 1756-L84E integrates seamlessly into existing multi-vendor environments.


Technical Specifications

General Specifications

  • Manufacturer: Rockwell Automation

  • Brand: Allen-Bradley

  • Part Number: 1756-L84E

  • Series: ControlLogix (5580 series)

  • Product Type: ControlLogix Controller

  • Enclosure: Open-Style (none)

  • UPC: 887172361364

Memory Specifications

ParameterValue
User Memory20 MB
Non-Volatile Expansion2GB Secure Digital (SD) card (1784-SD2)
Battery RequirementNone (battery-free operation)
Energy StorageModern energy storage solution integrated

I/O Capacity

ParameterValue
Maximum Discrete I/O128,000
Maximum Analog I/O4,000
Maximum Digital I/O128,000

Communication Specifications

Port TypeDetails
Ethernet Port1 (embedded)
Ethernet Speed10/100/1000 Mbps (1 GB)
USB Port1 (USB 2.0)
USB Speed12 Mbps
Maximum Ethernet Nodes250
Integrated Motion ControlYes (over EtherNet/IP)

Network Protocols Supported

  • EtherNet/IP

  • ControlNet

  • DeviceNet

  • Data Highway Plus

  • Remote I/O

  • SynchLink

  • Third-party process networks

Power and Current Specifications

ParameterValue
Current Draw (1.2 V DC)5.0 mA
Current Draw (5.1 V)1.20 mA
Power Dissipation6.2 W
Thermal Dissipation21.2 BTU per hour

Isolation Specifications

Isolation TypeValue
Isolation Voltage (Continuous)50 Volts
USB-to-Backplane50V isolation
Ethernet-to-Backplane50V isolation
USB-to-Ethernet50V isolation
Basic Insulation Test1000V AC for 1 minute

Environmental Specifications

ParameterValue
Operating Temperature0 to 60°C
Relative Humidity5 to 95% non-condensing (no derating)
Temperature CodeT4
Shock Tolerance30G
Vibration Tolerance2G

Compatible Chassis

The 1756-L84E fits in any of the following 1756 chassis.

SeriesModels
Series B, C1756-A4, A4K, A7, A7K, A10, A10K, A13, A13K, A17, A17K

Compatible Power Supplies

Standard Power Supplies:

  • 1756-PA50, 1756-PA72, 1756-PA72K, 1756-PA75, 1756-PA75K

  • 1756-PB50, 1756-PB72, 1756-PB72K, 1756-PB75, 1756-PB75K

  • 1756-PH75, 1756-PC75

Redundant Power Supplies:

  • 1756-PA75R, 1756-PA75RK

  • 1756-PB75R, 1756-PB75RK

  • 1756-PSCA2, 1756-PSCA2K

Programming and Configuration

  • Programming Software: Studio 5000 Logix Designer Application

  • Minimum Version: Version 3.0 or above

  • Task Capacity: Unlimited (with local I/O event triggers)

  • User Program Storage: 20 MB

  • Long-Term Storage: Optional 1784-SD2 2GB SD card


Installation Guide

Follow these steps to install the Allen-Bradley 1756-L84E correctly.

  1. Power Down Chassis: First, disconnect power from the 1756 chassis completely.

  2. Select Slot: Next, choose any available slot in the chassis (single slot width).

  3. Insert Controller: Then, slide the 1756-L84E firmly into the selected slot.

  4. Secure Module: After that, engage the locking mechanism to hold the controller in place.

  5. Connect Ethernet: Meanwhile, attach Ethernet cables to the 1GB port for network communication.

  6. Apply Power: Finally, restore power and verify the controller status.

The 1756-L84E requires no battery for memory retention. Therefore, the integrated energy storage module eliminates battery replacement maintenance. In addition, ensure proper chassis grounding for optimal noise immunity. Consequently, proper installation ensures reliable controller operation.


Package List

The package includes the following physical items.

  • Allen-Bradley 1756-L84E ControlLogix controller (1 piece)

  • Integrated energy storage module (factory installed)

  • Product label with part number and specifications

  • Anti-static protective bag for safe transport

*Note: The 1784-SD2 2GB Secure Digital card is not included. Ethernet and USB cables are sold separately. Programming software is not provided with this controller.*


Frequently Asked Questions (FAQ)

1. How much user memory does the 1756-L84E have?

The Allen-Bradley 1756-L84E provides 20 MB of user memory for program and data storage. Therefore, it handles large, complex control applications with ease. A 2GB Secure Digital card (1784-SD2) can expand non-volatile memory capacity. Consequently, you have ample storage for extensive programs and data logging.

2. What is the maximum I/O capacity of the 1756-L84E?

The Allen-Bradley 1756-L84E supports up to 128,000 discrete I/O points and 4,000 analog I/O points. Therefore, it is tailor-made for large-scale manufacturing environments. The controller manages both local I/O control and distributed I/O architectures. Consequently, massive automation systems are easily implemented with this controller.

3. Does the 1756-L84E require a battery?

No, the Allen-Bradley 1756-L84E does not require a battery for memory retention. Therefore, the integrated energy storage module eliminates battery replacement and disposal. This design makes the controller both user-friendly and environmentally friendly. Consequently, no battery-related maintenance is needed throughout the controller's life.

4. What communication speeds does the 1756-L84E support?

The Allen-Bradley 1756-L84E features a 1GB embedded Ethernet port supporting 10/100/1000 Mbps. Therefore, high-speed data exchange with HMIs, SCADA, and other controllers is possible. The USB 2.0 port supports 12 Mbps communication for programming. Consequently, the controller delivers superior performance for data-intensive applications.

5. What programming software is required for the 1756-L84E?

The Allen-Bradley 1756-L84E requires Studio 5000 Logix Designer Application version 3.0 or above. Therefore, ensure your software version meets this minimum requirement. The controller supports unlimited tasks through local I/O event triggers. Consequently, complex automation strategies are easily implemented.

6. What is the operating temperature range of the 1756-L84E?

The Allen-Bradley 1756-L84E operates at temperatures from 0 to 60°C. Therefore, it functions reliably in typical industrial environments. The controller withstands 30G shock and 2G vibration without performance degradation. Consequently, it is very durable for demanding manufacturing conditions.

7. What isolation does the 1756-L84E provide?

The Allen-Bradley 1756-L84E provides 50V continuous isolation between USB-to-backplane, Ethernet-to-backplane, and USB-to-Ethernet. Basic insulation is tested at 1000V AC for 1 minute. Therefore, your control system is protected from ground loops and electrical noise. Consequently, reliable communication is maintained even in electrically noisy environments.


Related Accessories

Enhance your ControlLogix system with these compatible parts.

  • SD Card: Allen-Bradley 1784-SD2 for 2GB non-volatile memory expansion

  • Chassis: Allen-Bradley 1756-A series for controller and I/O mounting

  • Power Supply: Allen-Bradley 1756-P series for backplane power

  • Ethernet Cable: Shielded Cat6 cable for 1GB communication

  • Programming Software: Rockwell Studio 5000 Logix Designer v3.0 or higher

Always use genuine Allen-Bradley components with the 1756-L84E. Therefore, third-party SD cards may not be compatible with the controller. In addition, verify chassis and power supply compatibility before installation. Consequently, using authentic parts ensures optimal controller performance and system reliability.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links