+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Allen-Bradley 1746-OA16 | SLC 500 AC Output Module 16 Channel

Introduction:

Allen-Bradley 1746-OA16 SLC 500 AC Output Module. 16 outputs at 120/240VAC. Two groups of 8 channels with removable terminal blocks.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-OA16
Type: Discrete AC Output Module
Condition: In Stock
Origin: U.S.A
Weight: 0.42
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Allen-Bradley 1746-OA16 is a discrete AC output module for the SLC 500 system. This module provides sixteen AC output channels in two groups of eight. It delivers nominal output voltages of 120/240V AC. The Allen-Bradley 1746-OA16 operates with an output voltage range of 85 to 265V AC. Users trust this module for general purpose AC load control applications.


Technical Specifications

The 1746-OA16 delivers reliable AC output switching with optical isolation. Below are the complete technical details.

General Specifications

  • Manufacturer: Rockwell Automation for industrial control reliability.

  • Brand: Allen-Bradley for SLC 500 compatibility.

  • Part Number: 1746-OA16 for precise identification.

  • Series: SLC 500 programmable controller family.

  • Module Type: Digital AC Output Module.

  • UPC: 10662468067062 for universal product identification.

  • UNSPSC: 32151705 for classification.

  • Applications: General Purpose AC load control.

  • Compatibility: SLC 500, CompactLogix, ControlLogix PAC.

Output Channel Specifications

  • Number of Outputs: Sixteen (16) outputs.

  • Output Groups: Two (2) groups of eight (8) outputs each.

  • Output Voltage (Nominal): 120/240 VAC.

  • Operating Voltage Range: 85 to 264 VAC.

  • Frequency Range: 47 to 63 Hz.

  • Output Delay Time (OFF to ON): 11.0 ms.

  • Output Delay Time (ON to OFF): 1 ms.

  • OFF State Leakage Current: 2 mA.

  • Load Current Minimum: 10 mA.

  • On-State Voltage Drop: 1.50V @ 0.50 A.

  • Surge Current per Point: 10.0 A for 25 ms.

Current Ratings by Temperature

  • Continuous Current per Point @ 30°C: 0.50 A.

  • Continuous Current per Point @ 55°C: 0.25 A.

  • Continuous Current per Point @ 60°C: 0.25 A.

  • Continuous Current per Module @ 30°C: 8.0 A.

  • Continuous Current per Module @ 60°C: 4.0 A.

Backplane Power Specifications

  • Backplane Current at 5.1 Volts: 0.370 A (370 milliamps).

  • Current Draw: 0.316 A typical.

  • I/O Memory Usage: 16-bit.

  • Slot Occupancy: Single slot of controller chassis.

Physical and Installation Specifications

  • Removable Terminal Blocks: Eliminates wire disconnection for module replacement.

  • Filter Circuitry: Built-in for signal noise reduction.

  • Optical Coupling: Provides isolation and noise immunity.

  • LED Indicators: Show output status values for troubleshooting.

  • Installation Limit: No limit as long as power supply supports current requirements.

Environmental Specifications

  • Ambient Operating Temperature: 32 to 140 degrees Fahrenheit (0 to 60°C).

  • Relative Humidity: 5 to 95% non-condensing.

  • Step Response: 60 ms in, 2.5 ms out.


Installation Guide

Follow these steps to install the Allen-Bradley 1746-OA16 correctly.

  1. Power Down the Chassis: Turn off all power to the SLC 500 rack.

  2. Verify Power Supply Capacity: Ensure backplane can supply 0.370 A at 5.1V.

  3. Locate an Available Slot: Find any empty I/O slot in the chassis.

  4. Insert the Module: Slide the 1746-OA16 into the slot carefully.

  5. Secure the Module: Lock using the retaining clips at top and bottom.

  6. Wire Removable Terminal Block: Connect AC loads to the 16 output terminals.

  7. Group Wiring: Note that outputs are in two groups of eight channels.

  8. Connect AC Supply: Wire 85-264 VAC, 47-63 Hz to the common terminals.

  9. Verify Load Current: Do not exceed 0.5A per point at 30°C or 0.25A at 60°C.

  10. Check Total Module Current: Keep under 8.0A at 30°C or 4.0A at 60°C.

  11. Apply Power: Turn on the backplane power to the chassis.

  12. Check LED Indicators: Verify output status LEDs for each channel.

  13. Test Outputs: Energize outputs and measure ON delay of 1 ms and OFF delay of 11 ms.

  14. Monitor Leakage Current: Ensure OFF-state leakage stays below 2 mA.

Installation Notes

  • The module can be installed as local or remote I/O.

  • No installation limit exists if power supply capacity is sufficient.

  • Optical coupling and filter circuitry reduce signal noise.

  • Removable terminal blocks allow easy module replacement.

  • Access output values using ladder logic in SLC 500 processors.


Packaging List

This unit ships as a new and original product.

  • Allen-Bradley 1746-OA16 Discrete AC Output Module

  • Removable terminal blocks (pre-installed)

  • Product data sheet with wiring diagram

  • Anti-static factory packaging bag


Frequently Asked Questions (FAQ)

1. What is the output voltage range of the 1746-OA16?
The Allen-Bradley 1746-OA16 operates with an output voltage range of 85 to 265 VAC at 47-63 Hz. Nominal voltages are 120/240 VAC.

2. How many outputs does this AC module provide?
The 1746-OA16 provides sixteen outputs arranged in two groups of eight channels each. Each group shares common connections.

3. What is the current rating per output on the 1746-OA16?
Each output on the Allen-Bradley 1746-OA16 handles 0.5 A at 30°C and 0.25 A at 60°C. The total module current is 8.0 A at 30°C or 4.0 A at 60°C.

4. What are the output delay times for this module?
The 1746-OA16 has an OFF to ON delay of 11.0 ms and an ON to OFF delay of 1 ms. OFF-state leakage current is 2 mA maximum.

5. Does the 1746-OA16 work with ControlLogix or CompactLogix systems?
Yes, the Allen-Bradley 1746-OA16 works with SLC 500, CompactLogix, and ControlLogix controllers. It installs as local or remote I/O.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap