6AR1310-0GG40-0AA0 Siemens Current Relay Overshoot Undershoot


Introduction:
The 6AR1310-0GG40-0AA0 is a monitoring relay from Siemens. It detects current overshoot and undershoot for AC and DC applications with 24V supply.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Siemens 6AR1310-0GG40-0AA0 Monitoring Relay Overview
The Siemens 6AR1310-0GG40-0AA0 is a digital monitoring relay for current applications. This device facilitates accurate detection of current overshoot conditions. Undershoot detection is also fully supported by this relay. Both AC and DC currents are compatible with the unit. Consequently, the Siemens 6AR1310-0GG40-0AA0 suits diverse industrial monitoring requirements. A 24V AC/DC power supply operates the device. Frequency compatibility includes both 50 Hz and 60 Hz systems. Therefore, this relay works in most global industrial locations.
Technical Specifications of 6AR1310-0GG40-0AA0
Manufacturer: Siemens.
Part Number: Siemens 6AR1310-0GG40-0AA0.
Product Line: I/O Modules (SIRIUS series).
Product Type: Monitoring relay.
Digital Device: Yes (fully electronic monitoring).
Current Monitoring Applications: Supported for both AC and DC.
Overshoot Detection: Supported (overcurrent protection).
Undershoot Detection: Supported (undercurrent protection).
Voltage Supply: [Color: Red] 24V AC/DC [/Color] (24 to 24V range).
Frequency: 50/60 Hz.
Operating Temperature Range: 0 to 40 degrees Celsius.
Storage Temperature Range: 0 to 50 degrees Celsius.
Maximum Operating Humidity: 80% without condensation.
Maximum Storage Humidity: 80% without condensation.
Key Features of 6AR1310-0GG40-0AA0
The Siemens 6AR1310-0GG40-0AA0 provides reliable current monitoring for industrial circuits. Overshoot detection alerts operators when current exceeds safe limits. Undershoot detection identifies when current drops below minimum thresholds. AC and DC compatibility broadens the relay's application range. A compact design saves valuable panel space. The 24V AC/DC supply voltage matches standard control system power. Operation at 50 or 60 Hz ensures global usability. Digital technology provides precise and repeatable trip points.
Installation Guidelines for 6AR1310-0GG40-0AA0
Before starting, disconnect all power to the control panel. Mount the Siemens 6AR1310-0GG40-0AA0 on standard DIN rail. Ensure adequate ventilation around the relay for cooling. Connect the 24V AC/DC supply voltage to the power terminals. Verify the supply matches the rated voltage before energizing. Wire the current monitoring input in series with the load. Set the overshoot and undershoot trip points according to your application. Test the relay operation by gradually increasing and decreasing load current. Verify the relay output changes state at the configured thresholds. Finally, secure all wiring and close the panel enclosure.
Application Scenarios for 6AR1310-0GG40-0AA0
The Siemens 6AR1310-0GG40-0AA0 monitors pump motor currents for dry run protection. Conveyor systems use this relay to detect belt jams through overcurrent. Fan applications benefit from undershoot detection when belts break. Lighting circuits need overcurrent protection against short circuits. Heating elements require monitoring for open circuit conditions. The 6AR1310-0GG40-0AA0 protects compressors from overloading. For critical processes, both overshoot and undershoot alarms ensure safe operation.
Package List for 6AR1310-0GG40-0AA0
One Siemens 6AR1310-0GG40-0AA0 monitoring relay
One DIN rail mounting clip (pre-installed)
One product label with terminal diagram
One instruction sheet for wiring and configuration
Common FAQs about the Siemens 6AR1310-0GG40-0AA0
Q1: What is the supply voltage for the 6AR1310-0GG40-0AA0?
The Siemens 6AR1310-0GG40-0AA0 operates on 24V AC or 24V DC power. Both voltage types are supported. Frequency must be 50 or 60 Hz for AC supply.
Q2: Does this relay monitor AC and DC currents?
Yes, both AC and DC currents are supported by the 6AR1310-0GG40-0AA0. This dual capability increases application flexibility significantly.
Q3: What detection functions does the 6AR1310-0GG40-0AA0 provide?
The relay detects both current overshoot (overcurrent) and undershoot (undercurrent). Consequently, it protects against high current faults and low current failures like broken wires.
Q4: What is the operating temperature range for this relay?
Operating temperature ranges from 0 to 40 degrees Celsius. Storage temperature ranges from 0 to 50 degrees Celsius. Maximum humidity is 80% without condensation for both operation and storage.
Q5: Can the 6AR1310-0GG40-0AA0 be used for motor protection?
Yes, this relay suits motor protection applications. Overshoot detection prevents motor burnout from overloads. Undershoot detection identifies loss of load conditions such as belt failure or pump cavitation.