140DRC83000C | Schneider Electric 8-Channel Discrete Output




Introduction:
The Schneider Electric 140DRC83000C is an eight-channel relay discrete output module for Modicon Quantum systems, rated for 20–250 V AC and 30–150 V DC loads.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
What Is the Schneider Electric 140DRC83000C?
The Schneider Electric this module is a relay discrete output module from the Modicon Quantum automation platform. It provides eight output channels with Form C contacts and supports multiple voltage ranges for flexible field control. Engineers selecting a discrete output card for oil and gas duty will find this module built for demanding environments.
The module combines a wide output voltage window with high mechanical durability and conformal coating. Those traits matter where vibration, humidity and temperature swings are routine. This buyer's guide walks through the specifications that determine whether this module fits a given application.

Key Features and Technical Specifications
- Output channels: Eight discrete outputs, each with one normally open and one normally closed contact in Form C configuration.
- Output voltage: 20...250 V AC, 30...150 V DC, and 5...30 V DC for low-voltage signaling.
- Maximum load current: Up to 5 A at 250/30 V AC/DC resistive, with lower ratings for inductive and tungsten loads.
- Surge current: 20 A for 10 ms capacitive loads, supporting brief inrush events.
- Switching frequency: 30 Hz resistive, with a derating formula for inductive loads.
- Mechanical durability: 10,000,000 cycles, indicating long service life under repeated actuation.
- Isolation: 1780 Vrms AC for one minute between channels and between channels and bus.
- Bus current requirement: 560 mA from the backplane.
- Operating temperature: 0 to 60 °C ambient, with storage from -40 to 85 °C.
- Protective treatment: Conformal coating (Humiseal 1A33) for humid or corrosive atmospheres.
The combination of Form C contacts and a 20...250 V AC range lets one module drive diverse field devices without external interposing relays in many cases. That reduces panel space and wiring complexity. For mission-critical operations, the 10,000,000-cycle mechanical rating supports long intervals between replacements.
How to Evaluate this module for Your Application
Start with the load. This module handles up to 5 A resistive at 250/30 V AC/DC, but inductive and tungsten loads carry lower ratings. Check the maximum load current table for your specific load type. Surge current reaches 20 A for 10 ms, which covers many capacitive inrush scenarios.
Next, confirm the voltage. The module accepts 20...250 V AC, 30...150 V DC and 5...30 V DC. That flexibility suits mixed-voltage panels, but each channel must stay within its configured range. The addressing requirement is 0.5 output word, so plan the I/O map accordingly.
Then assess the environment. Operating temperature is 0 to 60 °C, and conformal coating protects against humidity up to 95% without condensation. The module is rated for altitudes up to 5000 m and meets IEC 801-3 for electromagnetic field immunity at 9.1 V/m (10 V/m) from 80 to 2000 MHz. These ratings matter in oil and gas facilities where electrical noise and harsh atmospheres are common.
Finally, consider durability. Mechanical life is 10,000,000 cycles, while electrical durability varies by load from 50,000 to 200,000 cycles. Match the expected switching duty to these figures to estimate service life.

Integration with Modicon Quantum Systems
this module is a native Modicon Quantum module, so it fits Quantum backplanes and is configured through the platform's engineering software. It requires 560 mA of bus current, which should be included in the power budget. The module provides local signaling: a green LED for bus communication, a red LED for external fault, and eight green LEDs for output status.
Isolation between channels and the bus is 1780 Vrms AC for one minute, protecting the controller from field transients. The output overvoltage protection is internal by varistor at 275 V. For networks beyond the backplane, confirm gateway and cabling requirements with the supplier.
Reliability in Oil and Gas Environments
Conformal coating and a wide operating temperature range make this module suitable for demanding environments. The coating resists moisture and contaminants that degrade unprotected boards. The module also meets UL 508 and CSA C22.2 No 142 standards, and carries certifications including FM Class 1 Division 2, ABS, DNV and GL for industrial use.
For reliability you can depend on, schedule periodic inspections of terminal connections and enclosure integrity. The 10,000,000-cycle mechanical rating reduces wear-related failures, while the 20 A surge rating helps the contacts survive capacitive loads. These traits support dependable operation in mission-critical processes.
Frequently Asked Questions
What is the output voltage range of this module?
The Schneider Electric this module supports 20...250 V AC, 30...150 V DC and 5...30 V DC on its eight output channels.
How many output channels does this module provide?
this module provides eight discrete output channels, each with one normally open and one normally closed contact in Form C configuration.
What is the operating temperature range of this module?
The module operates from 0 to 60 °C ambient and can be stored from -40 to 85 °C.
Does this module have conformal coating?
Yes, this module features conformal coating (Humiseal 1A33) for protection in humid or corrosive environments.
What is the bus current requirement of this module?
The module draws 560 mA from the backplane bus, which must be accounted for in the power budget.
Contact PetroPartsOnline for parts suited to your application's requirements.