Allen‑Bradley T8850: 40-Channel Analogue/Digital Output FTA for Trusted TMR Systems

Introduction:

The T8850 is a 40‑channel analog and digital output field terminal assembly for ICS Triplex safety systems. It supports 18–32Vdc and 18–60Vdc supplies, carries ATEX/IECEx certifications, and allows reliable field control in hazardous industrial environments.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: ICS Triplex
Series: ICS Triplex
Part Number: T8550
Type: Expander Interface Module
Condition: In Stock
Origin: U.S.A
Weight: 0.80 kg
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry
Series: Triconex TMR / ICS Triplex

Product Type: Expander Interface Module

Category: I/O Modules

Gross Weight: 0.80 kg

Product Overview

The T8850 is a 40‑channel analog and digital output FTA by ICS Triplex. It supports 18–32Vdc and 18–60Vdc power, carries ATEX/IECEx hazardous area certifications, and delivers up to 2A per channel for safety‑critical field control.

Product Description

The T8850 is a high‑density field terminal assembly designed for Triconex TMR safety control systems.

This module acts as an expander interface to connect the main controller with field output devices.

It combines analog and digital output capabilities in a single unit to reduce cabinet space usage.

The T8850 accepts two wide voltage ranges to fit different power schemes in global industrial sites.

Each channel can drive up to 2A of current, supporting a variety of actuators and field loads.

Hazardous location certifications allow installation in potentially explosive industrial environments.

Sturdy terminal blocks ensure reliable wiring with specified torque and standard industrial wire sizes.

Its robust build maintains stable performance in harsh plant conditions with electrical noise present.

The T8850 integrates smoothly into TMR architectures to support safe and reliable output operation.

Technical Specifications

The T8850 serves as a 40‑channel analog and digital output field terminal assembly (FTA).

It functions as an expander interface module within ICS Triplex and Triconex safety systems.

Supply voltage ranges are 18–32 Vdc and 18–60 Vdc for flexible on‑site power compatibility.

Each output channel supports a maximum continuous current of 2A for field device control.

Total maximum current for the entire module is limited to 40A under full load conditions.

Recommended terminal torque is 0.5 N·m to ensure secure and long‑lasting wire connections.

Compatible wire sizes range from 30 AWG to 12 AWG, or 0.05 mm² to 2.5 mm².

The module holds certifications for ordinary locations, hazardous locations, ATEX, and IECEx.

These qualifications support safe deployment in oil, gas, and chemical processing environments.

The T8850 has a net weight of 0.8 kg, enabling lightweight and dense rack installation.

Its high channel count lowers overall system cost and simplifies cabinet layout design.

Installation Guide

Mount the T8850 in a protected cabinet close to field equipment for shorter cable runs.

Confirm the applied supply voltage falls within 18–32Vdc or 18–60Vdc before powering the unit.

Select wires between 30 AWG and 12 AWG for all input and output field connections.

Tighten each terminal screw to a torque of 0.5 N·m for stable electrical contact.

Route signal and power cables away from high‑voltage sources to avoid electromagnetic interference.

Ensure proper system grounding to meet hazardous location and certification requirements.

Insert the module firmly into its assigned rack slot and secure it to the backplane connector.

Power on the system and verify each channel to confirm proper operation of the T8850.

Do not exceed 2A per channel or 40A total to prevent overheating and module damage.

Keep the installation area clean and dry to maintain certification compliance over time.

Packing List

  • 1 × Allen-Bradley ICS Triplex T8850 Expander Interface Module
  • 1 × Installation and Specification Sheet
  • Anti‑static protective bag
  • Product identification label
Shipping methods: FedEx, UPS, DHL.

Frequently Asked Questions

1. How many channels does the T8850 provide?

The T8850 features 40 combined analog and digital output channels for field control.

2. What supply voltages does the T8850 support?

It accepts both 18–32 Vdc and 18–60 Vdc for broad industrial compatibility.

3. What certifications does the T8850 include?

The module holds Ord/HazLoc, ATEX, and IECEx certifications for hazardous areas.

4. What is the maximum current per channel on T8850?

Each channel can supply a maximum of 2A, with a 40A total module current limit.

5. What wire size and torque does the T8850 require?

It supports 30–12 AWG wire and requires a terminal torque of 0.5 N·m.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: sales@ubestplc.com

Contact: Klaus

 

Scan the QR code

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap