Bently Nevada 200150-10-05 Accelerometer 100mV/g 3/8-24 to 1 NPT
Introduction:
The 200150-10-05 is a general purpose accelerometer from Bently Nevada for Trendmaster 2000 and Pro systems.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Technical Specifications
Product Identification
-
Manufacturer: Bently Nevada produces this accelerometer in the U.S.A.
-
Product number: Use 200150-10-05 for ordering and reference.
-
Product type: This unit serves as a general purpose accelerometer.
-
System compatibility: Works with Trendmaster 2000 or Trendmaster Pro systems.
-
Channel type: Use with Standard Acceleration-to-Velocity channel type (-01).
Mounting and Approvals
-
Mounting stud option: The -10 code specifies [3/8-24 to 1 NPT].
-
Hex size: The stud has a [1-3/8 inch hex] profile.
-
Approvals option: The -05 code provides multiple approvals.
-
Certifications: Includes CSA, ATEX, and IECEx for hazardous areas.
-
Application type: Suitable for general application use.
Electrical Specifications (at +25°C)
-
Sensitivity @ 80 Hz: The 200150-10-05 delivers [10.2 mV/(m/s²) or 100 mV/g].
-
Tolerance: Sensitivity accuracy is ±12% at reference frequency.
-
Measurement range: The unit measures ±245 m/s² (±25 g) peak.
-
Frequency range: Operates from [10 to 1000 Hz (600 to 60,000 cpm)].
-
Frequency reference: All frequency response values reference 80 Hz.
-
Frequency tolerance: Response stays within ±10% across the range.
Performance Characteristics
-
Mounted resonant frequency: Exceeds 20 kHz (>1200 kcpm).
-
Amplitude linearity: Holds within ±2% from 1 to 10 g peak.
-
Transverse sensitivity: The 200150-10-05 has ≤7% transverse response.
-
Settling time: Reaches within 5% of bias in ≤300 ms.
-
Measurement range (low): Detects signals down to 14.7 mm/s² (1.5 mg).
Power and Output
-
Excitation voltage: Requires 4.7 to 5.5 Vdc for operation.
-
Quiescent current: Draws less than 800 µA during normal use.
-
Output bias voltage: Provides +2.5 ± 0.23 Vdc at zero acceleration.
-
Polarity: SIG+ becomes positive with respect to SIG- for acceleration from base to connector.
Environmental Ratings
-
Axial shock limit: Withstands 49,050 m/s² (5,000 g) peak shock.
-
Temperature range: Operates from -40°C to +105°C.
-
Hermetic sealing: Maximum leak rate is 5×10⁻⁸ atm•cc/s.
-
Relative humidity: The 200150-10-05 tolerates 100% condensing humidity.
-
Submersion: Not rated for continuous underwater use.
Physical Specifications
-
Size: The hex body measures 17.5 mm across with 45.7 mm height.
-
Weight: This accelerometer weighs only 58 g (2.0 oz) typically.
-
Mounting thread: Female thread type is 3/8-24.
-
Mounting torque: Apply [2.7 to 6.8 N•m (2 to 5 ft•lbf)].
-
Sensing element: The element uses durable ceramic material.
-
Sensing geometry: Shear design provides excellent stability.
-
Housing material: The 200150-10-05 has 316L stainless steel construction.
Installation Guide
Follow these steps to install the 200150-10-05 correctly.
-
Clean the mounting surface thoroughly before installation.
-
Apply a thin grease layer to the mounting stud threads.
-
Thread the stud into the 3/8-24 female port by hand.
-
Tighten with a wrench to the specified torque range.
-
Attach the cable connector to the accelerometer top.
-
Route the cable away from high vibration sources.
-
Connect the other end to your Trendmaster monitoring system.
For best results, install the 200150-10-05 at room temperature. Allow the mounting adhesive or compound 24 hours to cure before applying full vibration loads.
Package Contents
-
One 200150-10-05 general purpose accelerometer
-
One 3/8-24 to 1 NPT mounting stud (1-3/8 inch hex)
-
One protective cap for the connector
Frequently Asked Questions (FAQ)
1. Is the 200150-10-05 approved for use in explosive atmospheres?
Yes, the -05 approval option includes CSA, ATEX, and IECEx certifications. Therefore, you can install the 200150-10-05 in hazardous locations safely.
2. What is the difference between 200150-10-05 and 200150-09-05?
The only difference is the mounting stud. The 200150-10-05 has a 3/8-24 to 1 NPT stud with 1-3/8 inch hex, while the -09 version uses 3/8-24 to 3/4 NPT.
3. Can the 200150-10-05 measure very low frequency vibrations?
Yes, the frequency range starts at 10 Hz (600 cpm). Consequently, this accelerometer suits most rotating machinery monitoring applications.
4. How do I verify the 200150-10-05 is working correctly?
Measure the output bias voltage between SIG+ and SIG-. The 200150-10-05 should show +2.5 ± 0.23 Vdc with no vibration present.
5. What happens if I exceed the axial shock limit?
Exceeding 5,000 g peak shock may damage the ceramic sensing element. For this reason, handle the 200150-10-05 carefully during installation.