+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

EL3208 Beckhoff | Temperature Measurement Terminal 16-bit Resolution

Introduction:

Beckhoff EL3208 EtherCAT Terminal. 8-channel analog input for RTD (Pt100) sensors. 16-bit resolution with integrated digital filter.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Beckoff
Series: EL Series
Part Number: EL3208
Type: EtherCAT Terminal
Condition: In Stock
Origin: U.S.A
Weight: 0.9
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Beckhoff EL3208 is an analog input EtherCAT terminal for temperature measurement. It facilitates direct connection of eight resistance sensors in a compact 12 mm width. This terminal converts measured resistance values into temperature readings. The Beckhoff EL3208 supports various sensor characteristics including Pt100, Pt1000, Ni120, and KTY types. Users trust this terminal for high-density RTD temperature monitoring applications.


Technical Specifications

The EL3208 delivers precise temperature measurement with integrated filtering. Below are the complete technical details.

General Specifications

  • Product Type: EtherCAT Terminal.

  • Part Number: EL3208 for precise identification.

  • Product Status: Regular delivery.

  • Number of Inputs: 8 channels.

  • Technology: 2-wire sensor connection.

  • Signal Type: Single-ended.

  • Weight: Approx. 60 g for lightweight installation.

  • Housing Form: HD (High Density) housing with signal LEDs.

Sensor Compatibility

  • Pt Sensors: Pt100, Pt200, Pt500, Pt1000.

  • Ni Sensors: Ni100, Ni120, Ni1000.

  • Resistance Measurement: 10 Ω to 1/4 kΩ (e.g., potentiometer).

  • KTY Sensors: Various types (see documentation).

  • Connection Method: 2-wire.

  • Measuring Current: Less than 0.5 mA (load-dependent).

Temperature and Measurement Ranges

  • Pt Sensor Temperature Range: -200 to +850°C.

  • Ni Sensor Temperature Range: -60 to +250°C.

  • Resolution: 0.1°C per digit.

  • Measuring Error (Pt Sensors): Less than ±0.5°C.

Conversion and Filter Specifications

  • Conversion Time (Default): Approx. 170 ms.

  • Conversion Time (Configurable): 3 to 1600 ms.

  • Input Filter Limit Frequency: Typ. 1 kHz.

  • Integrated Digital Filter: Yes for noise rejection.

  • Distributed Clocks: Not supported.

Output Options

  • Resistance Output: Direct ohms reading.

  • Temperature Output: Transformed from resistance.

  • Process Image: Status bits in EtherCAT process image.

  • LED Indication: Measurement capability via light emitting diodes.

Power Specifications

  • Power Supply: Via the E-bus.

  • Current Consumption (E-bus): Typ. 140 mA.

  • Current Consumption (Power Contacts): Not used.

  • Electrical Isolation: 500 V (E-bus/signal voltage).

Special Features

  • Integrated Digital Filter: For signal smoothing.

  • Limit Value Monitoring: For alarm detection.

  • Configurable Conversion Time: 3 to 1600 ms range.

  • Multiple Sensor Types: Wide sensor compatibility.

Housing and Mechanical Data

  • Design Form: HD (High Density) housing with signal LEDs.

  • Material: Polycarbonate for durability.

  • Dimensions (W x H x D): 12 mm x 100 mm x 68 mm.

  • Installation: 35 mm DIN rail conforming to EN 60715 with lock.

  • Side by Side Mounting: Double slot and key connection.

  • Marking: Labeling of BZxxx series.

Wiring Specifications

  • Solid Conductor (s*): 0.08 to 1.5 mm².

  • Stranded Wire (st*): 0.25 to 1.5 mm².

  • With Ferrule (f*): 0.14 to 0.75 mm².

  • AWG Solid: AWG 28 to 16.

  • AWG Stranded: AWG 22 to 16.

  • AWG with Ferrule: AWG 26 to 19.

  • Stripping Length: 8 to 9 mm.

  • Termination: Spring actuation by screwdriver (fine-stranded).

  • Solid Conductor Termination: Direct plug-in technique.

Power Contact Specifications

  • Current Load Power Contacts: Imax: 10 A.

Environmental Specifications

  • Operating Temperature: -25 to +60°C.

  • Storage Temperature: -40 to +85°C.

  • Relative Humidity: 95% without condensation.

  • Vibration Resistance: Conforms to EN 60068-2-6.

  • Shock Resistance: Conforms to EN 60068-2-27.

  • EMC Immunity: Conforms to EN 61000-6-2.

  • EMC Emission: Conforms to EN 61000-6-4.

  • Protection Rating: IP20.

  • Installation Position: Variable.

Approvals and Markings

  • CE: Conforms to European standards.

  • UL: Underwriters Laboratories approved.


Installation Guide

Follow these steps to install the Beckhoff EL3208 correctly.

  1. Power Down the System: Turn off all power to the EtherCAT network.

  2. Mount DIN Rail: Ensure 35 mm DIN rail conforms to EN 60715.

  3. Attach Terminal: Clip the EL3208 onto the DIN rail until it locks.

  4. Connect E-bus: Insert the terminal into an existing EtherCAT terminal block.

  5. Side Mounting: Use double slot and key connection for adjacent terminals.

  6. Strip Wires: Remove 8 to 9 mm of insulation from each conductor.

  7. Terminate Wires: Insert solid wires directly or use screwdriver for stranded.

  8. Connect Pt100 Sensors: Wire up to eight 2-wire RTD sensors.

  9. Use Proper Wiring: Ensure 2-wire connection for each sensor channel.

  10. Verify Sensor Type: Configure terminal for Pt100, Pt1000, Ni, or KTY.

  11. Apply Power: Turn on the E-bus supply (no external power needed).

  12. Check LEDs: Observe measurement status via signal LEDs.

  13. Set Conversion Time: Configure from 3 to 1600 ms as needed.

  14. Monitor Temperature: Verify readings with 0.1°C resolution.

Installation Notes

  • The terminal measures resistance and converts to temperature.

  • Default conversion time is approximately 170 ms.

  • Measuring error for Pt sensors is less than ±0.5°C.

  • Electrical isolation is 500 V between E-bus and signal voltage.

  • The HD housing fits 8 channels in just 12 mm width.


Packaging List

This unit ships as a new and original product.

  • Beckhoff EL3208 EtherCAT Terminal (8-channel RTD input)

  • Product data sheet

  • Spring actuation tool information

  • Anti-static factory packaging bag


Frequently Asked Questions (FAQ)

1. What sensor types does the EL3208 support?
The Beckhoff EL3208 supports Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, KTY sensors, and resistance measurement. It operates with 2-wire technology.

2. What is the temperature measurement range for Pt sensors?
The EL3208 measures Pt sensors from -200 to +850°C. Ni sensors measure from -60 to +250°C with 0.1°C per digit resolution.

3. What is the conversion time of the EL3208?
The Beckhoff EL3208 has a default conversion time of approximately 170 ms. This is configurable from 3 to 1600 ms for application flexibility.

4. What is the measurement error for Pt100 sensors?
The EL3208 provides measuring error of less than ±0.5°C for Pt sensors. The integrated digital filter improves signal quality.

5. How many channels does the EL3208 provide in one housing?
The Beckhoff EL3208 provides 8 analog input channels in a compact 12 mm HD (High Density) housing. This saves significant panel space.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links