Allen-Bradley 1746-NI16V | SLC 500 Analog Input Module 16 Channels


Introduction:
Allen-Bradley 1746-NI16V SLC 500 Analog Input Module. 16 voltage input channels at 16-bit resolution. Programmable filter frequencies from 6-250 Hz.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Allen-Bradley 1746-NI16V is an analog input module for the SLC 500 system. This module features 16 voltage input channels for various signal ranges. It accepts ±10V DC, 1-5V DC, 0-5V DC, and 0-10V DC signals. The Allen-Bradley 1746-NI16V uses Sigma-Delta conversion with 16-bit resolution. Users trust this module for precise analog measurement in industrial applications.
Technical Specifications
The 1746-NI16V delivers accurate voltage measurement with flexible filtering. Below are the complete technical details.
General Specifications
Manufacturer: Rockwell Automation for industrial control reliability.
Brand: Allen-Bradley premium automation products.
Part Number: 1746-NI16V for precise identification.
Series: SLC 500 programmable controller family.
Module Type: Analog Input Module.
Number of Inputs: Sixteen (16) voltage input channels.
Chassis Location: Any I/O module slot except slot 0.
Slot Usage: Occupies only one slot in the chassis.
Electrical Signal Types
±10V DC: Bipolar voltage range.
1 to 5V DC: Unipolar with live zero.
0 to 5V DC: Standard unipolar range.
0 to 10V DC: Extended unipolar range.
Voltage Category: -10 to +10 Volts DC.
Conversion and Resolution
Conversion Type: Sigma - Delta for high accuracy.
Resolution: 16 bits for precise measurement.
Input Resolution: 312 µV per count.
Common Mode Voltage Range: ±10.25 Volts relative to analog common terminal.
Input Impedance: 20 Ω for minimal signal loading.
Input Filtering
Filter Type: Low-pass digital filter with programmable frequencies.
Input Filter Frequencies: 6 Hz, 10 Hz, 20 Hz, 40 Hz, 60 Hz, 80 Hz, 100 Hz, 250 Hz.
Bandwidth: 6-250 Hertz depending on filter selection.
Step Response: 9-630 milliseconds based on filter setting.
Backplane Current and Power
Backplane Current (5 Volts): 125 milliamps.
Backplane Current (24 Volts DC): 75 milliamps.
Backplane Power Consumption: 2.425 Watts maximum.
Power at 5V DC: 0.625 Watts.
Power at 24V DC: 1.8 Watts.
Isolation and Approvals
Isolation: 500V AC for 1 second between field and logic.
UL Listed: Yes for safety compliance.
C-UL Approved: Yes for Canadian standards.
CE Compliant: For all applicable directives.
Hazardous Environment: Approved for Class I Division 2 use.
LED Indicators
Number of LEDs: 5 green status indicators.
Channel Group Indicators: One LED for each group of 4 channels.
Module Status: One dedicated LED for module health.
Temperature and Environmental
Operating Temperature: -25 to 60°C (-13 to 140°F).
Non-Operating Temperature: -40 to 85°C (-40 to 185°F).
Relative Humidity: 5% to 95% without condensation.
Operating Vibration: Standard SLC 500 specifications.
Operating Shock: Standard SLC 500 specifications.
Drift Specifications
Gain Drift: 15 ppm per degree Celsius.
Input Offset Drift: 90 mV per degree Celsius.
Thermal Stability: Maintains accuracy across temperature range.
Wiring and Termination
Recommended Cable: Belden #8761 or equivalent.
Terminal Block: Replaceable terminal with part number 1746-RT25G.
AIFM Connector: 25-pin D-shell.
Pre-Wired Cables: Available in 0.5, 1, 2.5, and 5.0 meter lengths.
Compatible Terminal Blocks: 1492-AIFM8-3 and 1492-AIFM16-F-3.
Pre-Wired Advantage: Eliminates manual wiring errors with color coding.
Application Suitability
Primary Application: Combination 120V AC I/O systems.
Installation: Local chassis or expansion chassis (not slot 0).
Compatibility: SLC 500 processor via parallel rear-facing interface.
Installation Guide
Follow these steps to install the Allen-Bradley 1746-NI16V correctly.
Power Down the Chassis: Disconnect power before removing or inserting modules.
Locate an Available Slot: Find any empty slot except slot 0 (reserved for CPU).
Align the Module: Position the 1746-NI16V with the slot guides.
Insert the Module: Slide it into the slot until firmly seated.
Secure the Module: Tighten the mounting screws on the top and bottom.
Wire Input Signals: Connect voltage sources to the input terminals.
Use Recommended Cable: Belden #8761 or equivalent shielded cable.
Terminate Wiring: Use replaceable terminal block 1746-RT25G or pre-wired cables.
Select Filter Frequency: Program one of 8 filter settings from 6 to 250 Hz.
Apply Power: Turn on the chassis power to the system.
Monitor Status LEDs: Check the 5 green indicators for proper operation.
Configure Input Ranges: Set each channel for the appropriate voltage range.
Verify Readings: Check analog values in the SLC 500 processor.
Test Step Response: Measure response time based on selected filter.
Installation Notes
Do not install this module in slot 0 of the main chassis.
Removing or inserting a module with power can cause arcing.
The module occupies only one slot in the chassis.
Pre-wired cables with 1492 terminal blocks eliminate manual wiring errors.
This module is approved for Class I Division 2 hazardous environments.
Packaging List
This unit ships as a new and original product.
Allen-Bradley 1746-NI16V SLC 500 Analog Input Module
Product data sheet with filter frequency guide
Installation instructions
Anti-static factory packaging box
Frequently Asked Questions (FAQ)
1. What voltage input ranges does the 1746-NI16V accept?
The Allen-Bradley 1746-NI16V accepts ±10V DC, 1-5V DC, 0-5V DC, and 0-10V DC. Each of the 16 channels can be configured independently.
2. What filter frequencies are available on this analog input module?
The 1746-NI16V offers 8 programmable filter frequencies: 6, 10, 20, 40, 60, 80, 100, and 250 Hz. Step response varies from 9 to 630 milliseconds accordingly.
3. What is the backplane current consumption for the 1746-NI16V?
The Allen-Bradley 1746-NI16V consumes 125 mA at 5V DC and 75 mA at 24V DC. Total backplane power consumption is 2.425 Watts maximum.
4. Can I install this module in slot 0 of the SLC 500 chassis?
No, the 1746-NI16V can be installed in any I/O module slot except slot 0. Slot 0 is reserved for the SLC 500 controller.
5. What are the temperature and humidity ratings for this module?
The Allen-Bradley 1746-NI16V operates from -25 to 60°C with 5-95% non-condensing humidity. Storage temperature ranges from -40 to 85°C.
Welcome to learn about our business. We are a leading global provider of automation equipment and will provide you with complete and cost-effective product solutions. You are welcome to choose us, and our services will make you a long-term partner like our other customers.
Now please let us know your needs and suggestions.
About Ubest
Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.
Product Center
Contact Us
Phone:+86 180 3000 5825
Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China
Email: [email protected]
Contact: Klaus
Industry Links
© 2026, Ubest Automation Limited All Rights Reserved. sitemap