The ABB CI873A is an AC 800M communication interface for external Ethernet devices. This module connects to networks using the EtherNet/IP protocol. The ABB CI873A also supports DeviceNet protocol for industrial automation. It operates as a master device on the communication network. The TP867 Baseplate has two RJ45 Ethernet connectors on the module. Only the CH1 connector that supports 100 Mbps is used for operation. The ABB CI873A contains CEX-Bus logic, a communication unit, and a DC/DC converter. The converter supplies required voltage from +24 V supply through the CEX-Bus. Its article number is 3BSE092695R1 for accurate ordering.
Technical Specifications
General Specifications
Article Number: 3BSE092695R1.
Communication Protocol: EtherNet IP and DeviceNet.
Master or Slave: Master.
Transmission Speed: 10/100 Mbit/s.
Line Redundancy: No.
Module Redundancy: Yes.
Hot Swap: Yes.
Used Together with HI Controller: Yes.
System Compatibility
The ABB CI873A works with System 800xA versions 6.0.3.3, 6.1.1 and subsequent versions. This module supports 6 redundant pairs of CI873A from version 5.1 FP4.
CEX Bus and Connection Details
Max Units on CEX Bus: 12 units per system.
Connector Type: RJ-45 female (8-pin) on TP867 Baseplate.
Active Connector: CH1 only (supports 100 Mbps).
24 V Consumption (typical): 160 mA.
Physical Dimensions and Weight
Width: 59 mm (2.3 in.).
Height: 185 mm (7.3 in.).
Depth: 127.5 mm (5.0 in.).
Weight (including base): 700 g (1.5 lbs).
Environmental and Certification Details
Operating Temperature: +5°C to +55°C (+41°F to +131°F).
Storage Temperature: -40°C to +70°C (-40°F to +158°F).
Altitude: 2000 m according to IEC/EN 61131-2.
Pollution Degree: Degree 2 according to IEC/EN 61131-2.
Corrosion Protection: G3 compliant to ISA 71.04.
Relative Humidity: 5% to 95%, non-condensing.
Protection Class: IP20 according to EN60529, IEC 529.
CE Marking: Yes.
Safety and Hazardous Location Certifications
Electrical Safety: UL 61010-1, UL 61010-2-201.
Hazardous Location: UL 60079-15, cULus Class 1, Zone 2, AEx nA IIC T4, Ex nA IIC T4Gc X.
Marine Certificates: DNV-GL (Pending: ABS, BV, LR).
Compliance
Installation Guide
Follow these steps to install the ABB CI873A correctly:
Turn off power to the AC 800M controller system completely.
Mount the TP867 Baseplate onto the DIN rail or rack securely.
Insert the ABB CI873A module into the baseplate slot.
Secure the module using the built-in locking mechanism.
Connect the Ethernet cable to the CH1 RJ-45 connector only.
Configure the EtherNet/IP or DeviceNet protocol settings.
Power on the system and verify module detection on CEX-Bus.
Test redundant pair configuration if using multiple 3BSE092695R1 modules.
Packaging List
ABB CI873A communication interface module (1 unit)
TP867 Baseplate (1 unit, pre-attached)
Anti-static protective bag (1 piece)
Installation and commissioning manual (1 copy)
RJ-45 protective cap (1 piece)
Frequently Asked Questions (FAQ)
1. Which Ethernet connector should I use on the ABB CI873A?
Use only the CH1 RJ-45 connector on the TP867 Baseplate for 100 Mbps operation.
2. What communication protocols does the CI873A support?
The ABB CI873A supports EtherNet/IP and DeviceNet protocols as a master device.
3. Can I replace the module while the system runs?
Yes, the 3BSE092695R1 supports hot swap functionality for online replacement.
4. Is this module compatible with High Integrity controllers?
Yes, the ABB CI873A can be used together with HI controllers.
5. How many CI873A modules can I install on one CEX bus?
You can install a maximum of 12 ABB CI873A modules on a single CEX bus.