6SL3210-1KE13-2UF2 | Siemens 1.1 kW PROFINET Drive





Introduction:
Siemens 6SL3210-1KE13-2UF2 is a 1.1 kW PROFINET drive with 380–480 V input, 6 digital inputs, and -10 to 40 °C operation for oil and gas automation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
The Siemens 6SL3210-1KE13-2UF2 is a Communication PROFINET for industrial control and automation applications.
Siemens 6SL3210-1KE13-2UF2 is a 1.1 kW PROFINET communication drive designed for industrial automation in demanding environments. It accepts 380–480 V three-phase input and delivers 1.1 kW (1.50 hp) under low overload, making it a dependable choice for mission-critical oil and gas applications.
How Does the 6SL3210-1KE13-2UF2 Handle Electrical Network Fluctuations?
Field installations often face voltage sags and frequency variations. This drive tolerates line voltage from 380 to 480 V with +10 % / -20 % tolerance and line frequency from 47 to 63 Hz. Consequently, it maintains stable operation despite grid instability. The integrated PROFINET and EtherNet/IP communication enable seamless integration into plant networks.

What Protects the Drive in Harsh Oil and Gas Conditions?
Ambient temperature ranges from -10 to 40 °C during operation, and the unit withstands transport and storage from -40 to 70 °C. The IP20 / UL open type enclosure requires installation in a control cabinet. Air cooling with an integrated fan manages heat, with a power loss of 48.1 W. These rugged specifications ensure reliability you can depend on in demanding environments.
Key Technical Specifications
- Input voltage: 380 ... 480 V, 3 AC, +10 % -20 %
- Input frequency: 47 ... 63 Hz
- Rated power (LO): 1.10 kW (1.50 hp)
- Rated power (HO): 0.75 kW (1.00 hp)
- Operating temperature: -10 ... 40 °C
- Communication: PROFINET, EtherNet/IP
- Digital inputs: 6 standard, switching level 0→1 11 V, 1→0 5 V
- Degree of protection: IP20 / UL open type
- Efficiency: η 0.97
- Compliance: UL, cUL, CE, C-Tick (RCM)

How Does the Drive Simplify Integration and Installation?
Plug-in screw terminals on line side, motor end, and DC link accept conductor cross-sections from 1.00 to 2.50 mm² (AWG 18–14). Signal cables use 0.15 to 1.50 mm² (AWG 24–16). The compact FSAA frame measures 73 mm wide, 173 mm high, and 160 mm deep, with a net weight of 1.40 kg. Maximum motor cable length is 150 m shielded or unshielded. For network integration, wiring into PROFINET or EtherNet/IP may require an external gateway or connection module; confirm cables and gateways with PetroPartsOnline.
What Maintenance Practices Extend Drive Life?
Regular inspection of cooling fan operation and cabinet filters prevents overheating. Because the drive relies on air cooling, ensure unobstructed airflow and verify the 0.005 m³/s cooling air requirement. Check terminal tightness periodically and inspect for dust accumulation. These practices support the drive's 0.97 efficiency and reduce unplanned downtime in critical operations.
Why Choose This Drive for Oil and Gas Applications?
This unit combines PROFINET connectivity, wide voltage tolerance, and robust temperature ratings in a compact package. Its overload capability—150 % for 3 s and 110 % for 57 s in a 300 s cycle—handles transient loads. Typical applications include pump and fan control, conveyor systems, and process automation where reliable communication is essential. Contact PetroPartsOnline for parts suited to your application's requirements.
{"@context": "https://schema.org", "@graph": [{"@type": "Product", "name": "6SL3210-1KE13-2UF2 | Siemens 1.1 kW PROFINET Drive", "mpn": "6SL3210-1KE13-2UF2", "sku": "6SL3210-1KE13-2UF2", "brand": {"@type": "Brand", "name": "Siemens"}, "description": "The Siemens 6SL3210-1KE13-2UF2 is a Communication PROFINET for industrial control and automation applications. Siemens 6SL3210-1KE13-2UF2 is a 1.1 kW PROFINET communication drive designed for industrial automation in demanding environments. It accepts 380–480 V three-phase input and delivers 1.1 kW (1.50 hp) under low overload, making it a dependable choice for mission-critical oil and gas applications. How Does the 6SL3210-1KE13-2UF2 Handle Electrical Network Fluctuations? Field installations o", "image": ["https://www.petropartsonline.com/wp-content/uploads/2026/11/1793704012-6SL3210-1KE13-2UF2_1__fp7c32e0bb.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793704019-6SL3210-1KE13-2UF2_2__fp7a26fe8b.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793704024-6SL3210-1KE13-2UF2_3__fp6e40c701.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793703981-6SL3210-1KE13-2UF2_4__fp8123f307.jpg", "https://www.petropartsonline.com/wp-content/uploads/2026/11/1793704032-6SL3210-1KE13-2UF2_5__fpb03362c3.jpg"], "category": "I/O Modules"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "How Does the 6SL3210-1KE13-2UF2 Handle Electrical Network Fluctuations?", "acceptedAnswer": {"@type": "Answer", "text": "Field installations often face voltage sags and frequency variations. This drive tolerates line voltage from 380 to 480 V with +10 % / -20 % tolerance and line frequency from 47 to 63 Hz. Consequently, it maintains stable operation despite grid instability. The integrated PROFINET and EtherNet/IP communication enable seamless integration into plant networks."}}, {"@type": "Question", "name": "What Protects the Drive in Harsh Oil and Gas Conditions?", "acceptedAnswer": {"@type": "Answer", "text": "Ambient temperature ranges from -10 to 40 °C during operation, and the unit withstands transport and storage from -40 to 70 °C. The IP20 / UL open type enclosure requires installation in a control cabinet. Air cooling with an integrated fan manages heat, with a power loss of 48.1 W. These rugged specifications ensure reliability you can depend on in demanding environments."}}, {"@type": "Question", "name": "How Does the Drive Simplify Integration and Installation?", "acceptedAnswer": {"@type": "Answer", "text": "Plug-in screw terminals on line side, motor end, and DC link accept conductor cross-sections from 1.00 to 2.50 mm² (AWG 18–14). Signal cables use 0.15 to 1.50 mm² (AWG 24–16). The compact FSAA frame measures 73 mm wide, 173 mm high, and 160 mm deep, with a net weight of 1.40 kg. Maximum motor cable length is 150 m shielded or unshielded. For network integration, wiring into PROFINET or EtherNet/IP may require an external gateway or connection module; confirm cables and gateways with PetroPartsOnline."}}, {"@type": "Question", "name": "What Maintenance Practices Extend Drive Life?", "acceptedAnswer": {"@type": "Answer", "text": "Regular inspection of cooling fan operation and cabinet filters prevents overheating. Because the drive relies on air cooling, ensure unobstructed airflow and verify the 0.005 m³/s cooling air requirement. Check terminal tightness periodically and inspect for dust accumulation. These practices support the drive's 0.97 efficiency and reduce unplanned downtime in critical operations."}}, {"@type": "Question", "name": "Why Choose This Drive for Oil and Gas Applications?", "acceptedAnswer": {"@type": "Answer", "text": "This unit combines PROFINET connectivity, wide voltage tolerance, and robust temperature ratings in a compact package. Its overload capability—150 % for 3 s and 110 % for 57 s in a 300 s cycle—handles transient loads. Typical applications include pump and fan control, conveyor systems, and process automation where reliable communication is essential. Contact PetroPartsOnline for parts suited to your application's requirements."}}]}]}