Introduction:

The K-LB-1.6 is a 1-channel surge protection barrier from Pepperl+Fuchs. It mounts on standard DIN rails for easy installation. This barrier protects 6V circuits in IS or non-IS applications. It handles a maximum surge current of 20 kA (8/20 waveform). Furthermore, it provides 500V DC isolation between line and ground.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Beckoff
Series: K-System
Part Number: K-LB-1.6
Type: Surge Protection Barri
Condition: Subject to stock check
Weight: 0.12
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview: Pepperl+Fuchs K-LB-1.6

The K-LB-1.6 limits transients from lightning strikes and switching impulses. Specifically, it diverts transient current safely to ground. Moreover, it clamps signal line voltage to a safe level. The K-LB-1.6 provides low 12V line-to-line clamping voltage. Additionally, it offers 500V line-to-ground protection for sensitive instruments.

Technical Specifications

The K-LB-1.6 has a rated voltage of ≤ 6V DC. Its rated current is ≤ 250 mA for continuous operation. Leakage current is exceptionally low at ≤ 10 µA. The on-state voltage is ≤ 12V during surge events. Finally, ground insulation withstands 500V breakdown voltage.

  • Rated Voltage (Un): ≤ 6V

  • Rated Current (In): ≤ 250 mA

  • Leakage Current: ≤ 10 µA

  • On-state Voltage: ≤ 12V

  • Ground Insulation: 500V breakdown

  • Series Resistance: ≤ 0.3 Ω per conductor

The K-LB-1.6 has impressive surge handling capabilities. Nominal discharge current is 10 kA per core (8/20 waveform). For 10 surges, it handles 5 kA per core repeatedly. Maximum surge current reaches 20 kA per core for a single event. Consequently, this barrier protects against severe lightning strikes.

Protection Mechanism

The K-LB-1.6 operates automatically without user intervention. It diverts transient currents to ground within nanoseconds. Symmetrical response time is only 1 nanosecond for common mode surges. Asymmetrical response time is 100 nanoseconds for differential mode. Therefore, the protected equipment sees no damaging voltage spikes.

Surge Protection Specifications for the K-LB-1.6:

  • Response Time (Symmetrical): 1 ns

  • Response Time (Asymmetrical): 100 ns

  • Bandwidth: ≥ 40 kHz

  • Clamping Voltage (Line-Line): ≤ 12V

  • Clamping Voltage (Line-Ground): 500V

  • Reset: Automatic and uninterrupted

The K-LB-1.6 provides uninterrupted operation after each surge. It resets automatically without any manual action. This ensures continuous protection for your control system. The barrier does not degrade significantly after multiple surges.

Mechanical Specifications

The K-LB-1.6 has a compact housing for dense panel mounting. Its width is only 12.5 mm (0.5 inches). Height measures 114 mm (4.5 inches). Depth is 110 mm (4.3 inches). Total mass is approximately 100 grams.

  • Width: 12.5 mm (0.5 in)

  • Height: 114 mm (4.5 in)

  • Depth: 110 mm (4.3 in)

  • Weight: approx. 100 g (0.22 lbs)

  • Mounting: Standard 35 mm DIN rail

  • IP Rating: IP20 for indoor installation

The K-LB-1.6 mounts easily on any 35 mm DIN rail. It snaps into place without tools. The terminals accept wire sizes from 0.2 to 2.5 mm². Connection terminals are clearly labeled for protected and unprotected areas.

Terminal Connections

The K-LB-1.6 has clearly marked terminal assignments. Protected area connections use terminals 7 and 8. Unprotected area connections use terminals 1 and 2. This labeling prevents wiring errors during installation. Always connect the unprotected side to the field cable.

Terminal Assignments for the K-LB-1.6:

  • Terminals 1,2: Unprotected area (field side)

  • Terminals 7,8: Protected area (control side)

  • Ground Connection: Via DIN rail or separate terminal

  • Wire Gauge: 0.2 to 2.5 mm² (24 to 14 AWG)

  • Strip Length: 7 mm (0.28 in) typical

The K-LB-1.6 must connect to a solid and effective ground. Specifically, the ground system must comply with all applicable regulations. The barrier requires the same equipotential level as the protected instrument. Therefore, use a low-impedance ground connection.

Ambient Conditions

The K-LB-1.6 operates in a wide temperature range. Standard ambient temperature spans -30°C to +80°C. For Ex applications, refer to the EC-Type Examination Certificate. Temperature class T6 applies up to 50°C ambient. T5 applies up to 70°C, and T4 up to 80°C.

  • Standard Temperature: -30°C to +80°C (-22°F to +176°F)

  • Ex T6 Limit: 50°C ambient maximum

  • Ex T5 Limit: 70°C ambient maximum

  • Ex T4 Limit: 80°C ambient maximum

  • Humidity: 5% to 95% non-condensing

  • Storage Temperature: Same as operating range

The K-LB-1.6 maintains full performance across its temperature range. It uses components rated for industrial environments. The housing dissipates heat effectively without external cooling.

Ex-Approval Certifications

The K-LB-1.6 carries ATEX certification for hazardous areas. Its EC-Type Examination Certificate is PTB 00 ATEX 2176X. The device is approved for II 2(1)G Ex ia IIC T6. This allows installation in Zone 1 and Zone 2 gas environments. The associated apparatus may be in Zone 0.

Ex-Approval Details for the K-LB-1.6:

  • ATEX Certificate: PTB 00 ATEX 2176X

  • Group: II (surface industry)

  • Category: 2(1)G

  • Protection: Ex ia IIC T6

  • Ui (Input Voltage): 6V

  • Ii (Input Current): 250 mA

The K-LB-1.6 also holds IECEx approval BAS 14.0010X. CSA approval is documented in control drawing 116-0187 (cCSAus). Therefore, this barrier is suitable for global hazardous area installations. Always verify the certificate for specific gas groups and temperature classes.

Intrinsic Safety Compatibility

The K-LB-1.6 protects intrinsic safety barriers and signal conditioners. Specifically, it protects instruments with more than 500V isolation-to-ground. This includes most field instruments and isolators. The barrier does not compromise the intrinsic safety of the circuit.

  • Compatible Devices: IS barriers, signal conditioners, field instruments

  • Isolation Requirement: >500V to ground

  • Circuit Type: IS or non-IS applications

  • Entity Parameters: Ui = 6V, Ii = 250 mA

  • Entity Capacitance: No significant added capacitance

The K-LB-1.6 adds minimal series resistance of only 0.3 Ω per conductor. Consequently, it does not affect loop operation. The barrier also adds negligible capacitance to the circuit. Therefore, entity calculations remain largely unchanged.

Installation Guidelines

Install the K-LB-1.6 as close as possible to the protected instrument. Specifically, place it at the cabinet entry point for field cables. Mount the barrier on a grounded DIN rail for proper surge drainage. Connect the unprotected side to the field cable coming from outside.

Key Installation Points for the K-LB-1.6:

  • Location: Near cabinet entry point

  • Grounding: Low impedance to main earth ground

  • Wire Length: Keep as short as possible

  • Separation: Separate from high voltage cables

  • Labeling: Mark protected and unprotected sides

The K-LB-1.6 requires a solid ground connection at the same equipotential level. Use a ground bus bar or grounded DIN rail. Keep ground wires shorter than 0.5 meters when possible. Multiple barriers can share the same ground reference.

Application Examples

The K-LB-1.6 protects many types of field instruments. For instance, it safeguards 4-20 mA transmitters in lightning-prone areas. Similarly, it protects RTD and thermocouple inputs. The barrier also guards digital inputs and outputs.

Typical Applications for the K-LB-1.6:

  • 4-20 mA loop-powered transmitters

  • RTD and thermocouple temperature sensors

  • Digital inputs from remote switches

  • Solenoid valve and actuator control circuits

  • Communication lines (RS-485 limited bandwidth)

The K-LB-1.6 bandwidth of 40 kHz suits most process signals. However, it is not suitable for high-speed communications. For Ethernet or PROFIBUS, use dedicated data line protectors.

Package Contents

Your purchase of the K-LB-1.6 includes:

  • (1) Pepperl+Fuchs Surge Protection Barrier – K-LB-1.6

  • (1) Standard manufacturer packaging

  • (1) Product label with certification markings

Frequently Asked Questions (FAQ)

Q: Can the K-LB-1.6 be used for both IS and non-IS circuits?
A: Yes, the K-LB-1.6 works for both intrinsic safety and non-IS applications. However, for IS circuits, follow the entity parameters in the certificate.

Q: What is the maximum surge current the K-LB-1.6 can handle?
A: The K-LB-1.6 handles 20 kA per core (8/20 waveform) for a single event. For repeated surges, it handles 10 kA per core.

Q: Does the K-LB-1.6 need to be replaced after a surge event?
A: No, the K-LB-1.6 resets automatically after each surge. However, after multiple severe surges, test the barrier for proper operation.

Q: What is the ambient temperature limit for Ex T6 applications?
A: For Ex T6 classification, the K-LB-1.6 limits ambient temperature to 50°C. For T4 classification, it allows up to 80°C.

Q: Can the K-LB-1.6 be mounted on any DIN rail?
A: Yes, the K-LB-1.6 fits standard 35 mm DIN rails. Ensure the DIN rail is properly grounded for effective surge protection.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap