Pepperl+Fuchs K-LB-1.6 Surge Protection Barrier DIN Rail 20kA


Introduction:
The K-LB-1.6 is a 1-channel surge protection barrier from Pepperl+Fuchs. It mounts on standard DIN rails for easy installation. This barrier protects 6V circuits in IS or non-IS applications. It handles a maximum surge current of 20 kA (8/20 waveform). Furthermore, it provides 500V DC isolation between line and ground.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview: Pepperl+Fuchs K-LB-1.6
The K-LB-1.6 limits transients from lightning strikes and switching impulses. Specifically, it diverts transient current safely to ground. Moreover, it clamps signal line voltage to a safe level. The K-LB-1.6 provides low 12V line-to-line clamping voltage. Additionally, it offers 500V line-to-ground protection for sensitive instruments.
Technical Specifications
The K-LB-1.6 has a rated voltage of ≤ 6V DC. Its rated current is ≤ 250 mA for continuous operation. Leakage current is exceptionally low at ≤ 10 µA. The on-state voltage is ≤ 12V during surge events. Finally, ground insulation withstands 500V breakdown voltage.
Rated Voltage (Un): ≤ 6V
Rated Current (In): ≤ 250 mA
Leakage Current: ≤ 10 µA
On-state Voltage: ≤ 12V
Ground Insulation: 500V breakdown
Series Resistance: ≤ 0.3 Ω per conductor
The K-LB-1.6 has impressive surge handling capabilities. Nominal discharge current is 10 kA per core (8/20 waveform). For 10 surges, it handles 5 kA per core repeatedly. Maximum surge current reaches 20 kA per core for a single event. Consequently, this barrier protects against severe lightning strikes.
Protection Mechanism
The K-LB-1.6 operates automatically without user intervention. It diverts transient currents to ground within nanoseconds. Symmetrical response time is only 1 nanosecond for common mode surges. Asymmetrical response time is 100 nanoseconds for differential mode. Therefore, the protected equipment sees no damaging voltage spikes.
Surge Protection Specifications for the K-LB-1.6:
Response Time (Symmetrical): 1 ns
Response Time (Asymmetrical): 100 ns
Bandwidth: ≥ 40 kHz
Clamping Voltage (Line-Line): ≤ 12V
Clamping Voltage (Line-Ground): 500V
Reset: Automatic and uninterrupted
The K-LB-1.6 provides uninterrupted operation after each surge. It resets automatically without any manual action. This ensures continuous protection for your control system. The barrier does not degrade significantly after multiple surges.
Mechanical Specifications
The K-LB-1.6 has a compact housing for dense panel mounting. Its width is only 12.5 mm (0.5 inches). Height measures 114 mm (4.5 inches). Depth is 110 mm (4.3 inches). Total mass is approximately 100 grams.
Width: 12.5 mm (0.5 in)
Height: 114 mm (4.5 in)
Depth: 110 mm (4.3 in)
Weight: approx. 100 g (0.22 lbs)
Mounting: Standard 35 mm DIN rail
IP Rating: IP20 for indoor installation
The K-LB-1.6 mounts easily on any 35 mm DIN rail. It snaps into place without tools. The terminals accept wire sizes from 0.2 to 2.5 mm². Connection terminals are clearly labeled for protected and unprotected areas.
Terminal Connections
The K-LB-1.6 has clearly marked terminal assignments. Protected area connections use terminals 7 and 8. Unprotected area connections use terminals 1 and 2. This labeling prevents wiring errors during installation. Always connect the unprotected side to the field cable.
Terminal Assignments for the K-LB-1.6:
Terminals 1,2: Unprotected area (field side)
Terminals 7,8: Protected area (control side)
Ground Connection: Via DIN rail or separate terminal
Wire Gauge: 0.2 to 2.5 mm² (24 to 14 AWG)
Strip Length: 7 mm (0.28 in) typical
The K-LB-1.6 must connect to a solid and effective ground. Specifically, the ground system must comply with all applicable regulations. The barrier requires the same equipotential level as the protected instrument. Therefore, use a low-impedance ground connection.
Ambient Conditions
The K-LB-1.6 operates in a wide temperature range. Standard ambient temperature spans -30°C to +80°C. For Ex applications, refer to the EC-Type Examination Certificate. Temperature class T6 applies up to 50°C ambient. T5 applies up to 70°C, and T4 up to 80°C.
Standard Temperature: -30°C to +80°C (-22°F to +176°F)
Ex T6 Limit: 50°C ambient maximum
Ex T5 Limit: 70°C ambient maximum
Ex T4 Limit: 80°C ambient maximum
Humidity: 5% to 95% non-condensing
Storage Temperature: Same as operating range
The K-LB-1.6 maintains full performance across its temperature range. It uses components rated for industrial environments. The housing dissipates heat effectively without external cooling.
Ex-Approval Certifications
The K-LB-1.6 carries ATEX certification for hazardous areas. Its EC-Type Examination Certificate is PTB 00 ATEX 2176X. The device is approved for II 2(1)G Ex ia IIC T6. This allows installation in Zone 1 and Zone 2 gas environments. The associated apparatus may be in Zone 0.
Ex-Approval Details for the K-LB-1.6:
ATEX Certificate: PTB 00 ATEX 2176X
Group: II (surface industry)
Category: 2(1)G
Protection: Ex ia IIC T6
Ui (Input Voltage): 6V
Ii (Input Current): 250 mA
The K-LB-1.6 also holds IECEx approval BAS 14.0010X. CSA approval is documented in control drawing 116-0187 (cCSAus). Therefore, this barrier is suitable for global hazardous area installations. Always verify the certificate for specific gas groups and temperature classes.
Intrinsic Safety Compatibility
The K-LB-1.6 protects intrinsic safety barriers and signal conditioners. Specifically, it protects instruments with more than 500V isolation-to-ground. This includes most field instruments and isolators. The barrier does not compromise the intrinsic safety of the circuit.
Compatible Devices: IS barriers, signal conditioners, field instruments
Isolation Requirement: >500V to ground
Circuit Type: IS or non-IS applications
Entity Parameters: Ui = 6V, Ii = 250 mA
Entity Capacitance: No significant added capacitance
The K-LB-1.6 adds minimal series resistance of only 0.3 Ω per conductor. Consequently, it does not affect loop operation. The barrier also adds negligible capacitance to the circuit. Therefore, entity calculations remain largely unchanged.
Installation Guidelines
Install the K-LB-1.6 as close as possible to the protected instrument. Specifically, place it at the cabinet entry point for field cables. Mount the barrier on a grounded DIN rail for proper surge drainage. Connect the unprotected side to the field cable coming from outside.
Key Installation Points for the K-LB-1.6:
Location: Near cabinet entry point
Grounding: Low impedance to main earth ground
Wire Length: Keep as short as possible
Separation: Separate from high voltage cables
Labeling: Mark protected and unprotected sides
The K-LB-1.6 requires a solid ground connection at the same equipotential level. Use a ground bus bar or grounded DIN rail. Keep ground wires shorter than 0.5 meters when possible. Multiple barriers can share the same ground reference.
Application Examples
The K-LB-1.6 protects many types of field instruments. For instance, it safeguards 4-20 mA transmitters in lightning-prone areas. Similarly, it protects RTD and thermocouple inputs. The barrier also guards digital inputs and outputs.
Typical Applications for the K-LB-1.6:
4-20 mA loop-powered transmitters
RTD and thermocouple temperature sensors
Digital inputs from remote switches
Solenoid valve and actuator control circuits
Communication lines (RS-485 limited bandwidth)
The K-LB-1.6 bandwidth of 40 kHz suits most process signals. However, it is not suitable for high-speed communications. For Ethernet or PROFIBUS, use dedicated data line protectors.
Package Contents
Your purchase of the K-LB-1.6 includes:
(1) Pepperl+Fuchs Surge Protection Barrier – K-LB-1.6
(1) Standard manufacturer packaging
(1) Product label with certification markings
Frequently Asked Questions (FAQ)
Q: Can the K-LB-1.6 be used for both IS and non-IS circuits?
A: Yes, the K-LB-1.6 works for both intrinsic safety and non-IS applications. However, for IS circuits, follow the entity parameters in the certificate.
Q: What is the maximum surge current the K-LB-1.6 can handle?
A: The K-LB-1.6 handles 20 kA per core (8/20 waveform) for a single event. For repeated surges, it handles 10 kA per core.
Q: Does the K-LB-1.6 need to be replaced after a surge event?
A: No, the K-LB-1.6 resets automatically after each surge. However, after multiple severe surges, test the barrier for proper operation.
Q: What is the ambient temperature limit for Ex T6 applications?
A: For Ex T6 classification, the K-LB-1.6 limits ambient temperature to 50°C. For T4 classification, it allows up to 80°C.
Q: Can the K-LB-1.6 be mounted on any DIN rail?
A: Yes, the K-LB-1.6 fits standard 35 mm DIN rails. Ensure the DIN rail is properly grounded for effective surge protection.
Welcome to learn about our business. We are a leading global provider of automation equipment and will provide you with complete and cost-effective product solutions. You are welcome to choose us, and our services will make you a long-term partner like our other customers.
Now please let us know your needs and suggestions.
About Ubest
Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.
Product Center
Contact Us
Phone:+86 180 3000 5825
Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China
Email: [email protected]
Contact: Klaus
Industry Links
© 2026, Ubest Automation Limited All Rights Reserved. sitemap