Beckhoff EL4034 EtherCAT Terminal 4-Channel Analog Output ±10V


Introduction:
The EL4034 is a 4-channel analog output terminal for EtherCAT. It generates ±10V signals with 12-bit resolution and electrical isolation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview
The Beckhoff EL4034 is a 4-channel analog output EtherCAT terminal. This terminal generates voltage signals from -10V to +10V. It has 12-bit resolution for precise control. Electrical isolation protects the E-bus from output signals. The output stages receive power from the 24V supply via power contacts. All four output channels share a common ground potential. The terminal uses 2-wire single-ended connection technology.
For inquiries, contact us at +86 158 8020 0923 (WhatsApp).
Part Number Breakdown (Tree Structure)
- EL → Product Series
- EtherCAT Terminal
- Beckhoff automation system
- 4034 → Specific Model
- 4-channel analog output
- Voltage output type (±10V)
- 12-bit resolution
Key Specifications
- Brand: Beckhoff
- Part Number: Beckhoff EL4034
- Number of Outputs: 4 channels
- Connection Technology: 2-wire, single-ended
- Signal Voltage: -10V to +10V
- Resolution: 12 bits
- Output Error: < 0.1% (relative to end value)
- Load Range: > 5 kΩ (short-circuit proof)
Performance and Timing
- Conversion Time: Approximately 250 microseconds
- Distributed Clocks: Yes, supported
- Distributed Clock Precision: << 1 microsecond
- High precision for synchronized output across multiple terminals.
Process Image and Data Format
- Bit Width in Process Image: 4 x 16 bits (AO output)
- Each channel uses 16 bits of output data.
- Total of 64 bits (8 bytes) per terminal.
Power Supply
- Power Supply (Output Stages): 24V DC via power contacts
- Current Consumption (Power Contacts): 25 mA typical
- Current Consumption (E-bus): 140 mA typical
- Maximum Current Load Power Contacts: 10 A
Isolation and Protection
- Electrical Isolation: 500 V (E-bus to signal voltage)
- Short-Circuit Protection: Yes, outputs are short-circuit proof
- Outputs withstand short to ground without damage.
LED Indicators
- Signal state LEDs for each of the 4 channels.
- LEDs indicate output signal status at a glance.
- Power LED shows E-bus supply status.
Special Features
- Watchdog Function: Optional, user-configurable
- Watchdog Output Value: User-specific with ramp function
- User Synchronization: Can be activated
- Safe output behavior during communication loss.
Environmental Specifications
- Operating Temperature: -25°C to +60°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 95% maximum (non-condensing)
- Vibration Resistance: Conforms to EN 60068-2-6
- Shock Resistance: Conforms to EN 60068-2-27
- EMC Immunity: Conforms to EN 61000-6-2
- EMC Emission: Conforms to EN 61000-6-4
- Protection Rating: IP20
- Installation Position: Variable
Ex Approval and Markings
ATEX Approval:
- II 3 G Ex nA IIC T4 Gc
Other Approvals:
- CE
- UL
Housing and Physical Data
- Design Form: Compact terminal housing with signal LEDs
- Material: Polycarbonate
- Width: 12 mm
- Height: 100 mm
- Depth: 68 mm
- Weight: Approx. 85 g (0.09 kg)
Mounting and Installation
- Mount on 35 mm DIN rail (EN 60715 standard).
- Locking mechanism secures terminal to rail.
- Side by side mounting via double slot and key connection.
- Marking using BZxxx series labeling system.
- Pluggable wiring for all ESxxxx terminals (ES4034 version).
Wiring Specifications
Conductor Types and Cross-Sections (EL4034):
- Solid wire (s): 0.08 to 2.5 mm²
- Stranded wire (st): 0.08 to 2.5 mm²
- With ferrule (f): 0.14 to 1.5 mm²
AWG Cross-Sections (EL4034):
- Solid wire (s): AWG 28 to 14
- Stranded wire (st): AWG 28 to 14
- With ferrule (f): AWG 26 to 16
Termination Details:
- Stripping length: 8 to 9 mm
- Spring actuation using screwdriver
Installation Guide
- Turn off all power before installation.
- Mount the DIN rail securely in your control cabinet.
- Clip the Beckhoff EL4034 onto the DIN rail.
- Push the terminal to the right until it locks.
- Connect 24V DC power to the power contacts.
- Wire output loads (minimum 5 kΩ) to channels 1-4.
- Insert wires into spring terminals using a screwdriver.
- Stripping length is 8-9 mm for proper connection.
- Apply E-bus power and check LED indicators.
- Configure watchdog settings as needed for safety.
Wiring Notes
- All output channels share common ground potential.
- Do not exceed 10V output range (±10V).
- Minimum load resistance is 5 kΩ per channel.
- Use twisted pair shielded cable for long runs.
- Connect cable shield to ground at one end only.
Maintenance Tips
- Check LED status during normal operation.
- Inspect terminal connections for tightness annually.
- Keep terminal free from dust and moisture.
- Ensure ambient temperature stays below 60°C.
- Verify output voltage accuracy (< 0.1% error).
- Replace terminal if output error exceeds specification.
Troubleshooting Tips
- If output signal is incorrect, check load resistance (>5 kΩ).
- Verify 24V power supply is connected to power contacts.
- Check E-bus connection if no output updates occur.
- Use TwinCAT software to monitor output values.
- Test watchdog function by disconnecting communication.
- Check distributed clock synchronization precision.
Typical Applications
- Servo drive analog input control (±10V interface)
- Valve positioner control in process automation
- Variable frequency drive speed reference
- Actuator control for dampers and gates
- Test equipment signal generation
- Motion control systems requiring synchronized outputs
- Hazardous area installations (ATEX Zone 2)
Package Contents
- One Beckhoff EL4034 EtherCAT analog output terminal
- One product label
- Wiring accessories not included
Warranty and Shipping
- 12 months factory warranty from shipment date.
- Warranty covers manufacturing defects only.
- Overload or short circuit on output below 5kΩ may damage unit.
- Shipping options: FedEx, UPS, DHL.
- Tracking number provided after shipment.
Frequently Asked Questions (FAQ)
Q1: How many output channels does the EL4034 have?
The Beckhoff EL4034 has 4 analog output channels. Each channel generates -10V to +10V signals. The outputs use 2-wire single-ended connection technology.
Q2: What is the conversion time of this terminal?
Conversion time is approximately 250 microseconds. This is very fast for analog output applications. Distributed clock precision is less than 1 microsecond.
Q3: What load can the EL4034 drive?
Minimum load resistance is 5 kΩ per channel. The outputs are short-circuit proof. Do not connect loads below 5 kΩ for normal operation.
Q4: What is the output error of the EL4034?
Output error is less than 0.1% relative to end value. Resolution is 12 bits. This provides accurate voltage control for most industrial applications.
Q5: Does the EL4034 support distributed clocks?
Yes, this terminal supports distributed clocks. Precision is less than 1 microsecond. This enables synchronized output across multiple EtherCAT terminals. Ideal for motion control applications.
Buying Guide
When you buy a Beckhoff EL4034 analog output terminal, follow these tips. First, count your output channels. This terminal gives 4 channels. Second, verify your voltage range is ±10V. Third, check your load impedance. Minimum is 5 kΩ per channel. Fourth, consider conversion speed. This terminal converts in 250 µs. Fifth, review distributed clock needs. This terminal supports high precision synchronization. Sixth, check your Ex zone requirement. This terminal is ATEX Zone 2 approved. Seventh, verify your temperature range. Operating range is -25°C to +60°C. Eighth, calculate your E-bus power budget. Each terminal draws 140 mA typical. Ninth, review watchdog configuration. Set safe output values for communication loss. Tenth, review warranty terms. We offer 12 months coverage. Eleventh, choose your shipping method. We use FedEx, UPS, and DHL. Finally, test each output channel with a known load before connecting to field equipment.
Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited