Pepperl+Fuchs FS-LB-I Surge Protection Barrier 10kA Ex ia IIC


Introduction:
The FS-LB-I is a single-channel surge protection barrier from Pepperl+Fuchs. This field mount module features a stainless steel housing with M20 x 1.5 thread. It diverts transient currents up to 10 kA safely to ground. The barrier provides 85V line-to-line and 500V line-to-ground clamping voltage. Furthermore, it carries Ex ia IIC T6 certification for hazardous area installation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Product Overview: Pepperl+Fuchs FS-LB-I
The FS-LB-I protects field instruments from damaging electrical transients. These transients may originate from lightning strikes or switching impulses. The barrier limits signal line voltage to a safe level during surge events. It installs directly into conduit or cable gland openings on process transmitters. Therefore, this device is ideal for protecting 4-20 mA loops and other low-power circuits.
Technical Specifications
The FS-LB-I operates with rated voltage up to 48V DC. Rated current reaches 250 mA maximum for typical instrument loops. Leakage current is extremely low at 5 µA or less. On-state voltage clamps at 85V between lines. Ground insulation withstands 500V breakdown voltage.
Rated Voltage (Un): ≤ 48 V
Rated Current (In): ≤ 250 mA
Leakage Current: ≤ 5 µA
On-state Voltage: ≤ 85 V
Ground Insulation: ≥ 500 V breakdown
Discharge Current: 10 kA line to ground (common mode)
The FS-LB-I handles significant surge currents without damage. Common mode discharge reaches 10 kA line to ground. Differential mode discharge reaches 5 kA line to line. Response time is extremely fast for effective protection. Symmetrical response is 1 nanosecond, while asymmetrical response is 100 nanoseconds.
Mechanical Construction
The FS-LB-I features a robust stainless steel housing for harsh environments. Housing material is stainless steel 1.4401 (AISI 316) with polished surface. This material resists corrosion in chemical and offshore applications. The module has IP67 protection against dust and water ingress. Cable length is 0.4 meters for flexible installation.
Housing Material: Stainless steel 1.4401 (AISI 316)
Surface Finish: All over polished
Degree of Protection: IP67
Dimensions: AF22 x 77 mm (0.9 x 3 inches)
Mounting Thread: M20 x 1.5
Mass: Approximately 200 g
The FS-LB-I mounts directly into an M20 x 1.5 threaded opening. This matches standard conduit and cable gland ports on most transmitters. Installation requires no additional mounting hardware or brackets. The compact size (AF22) fits tight spaces easily. Total length of 77 mm suits most field junction boxes.
Electrical Characteristics
The FS-LB-I provides reliable clamping across a wide frequency range. Bandwidth reaches 40 kHz for fast signal response. Insertion loss is minimal due to low on-state voltage. The barrier protects both line-to-line and line-to-ground paths. Consequently, instruments with less than 500V isolation are fully protected.
Key Electrical Features of the FS-LB-I:
Bandwidth: ≥ 40 kHz
Response Time (Symmetrical): 1 ns
Response Time (Asymmetric): 100 ns
Clamping Voltage (Line-Line): 85 V
Clamping Voltage (Line-Ground): 500 V
The FS-LB-I limits induced transients from various sources effectively. Lightning strikes produce high-energy surges that this barrier diverts. Switching impulses from nearby equipment are also suppressed. The barrier returns to normal operation after each surge event. No reset or replacement is needed after most transient events.
Hazardous Area Certification
The FS-LB-I carries EC-Type Examination Certificate PTB 00 ATEX 2175. It is certified for II 2G EEx ia IIC T6 applications. This allows installation in Zone 1 and Zone 2 hazardous areas. The T6 temperature class permits use with gases having ignition temperatures above 85°C.
Ex Data for the FS-LB-I:
Certificate: PTB 00 ATEX 2175
Group/Category: II 2G
Protection Type: EEx ia IIC
Temperature Class: T6
Voltage Ui: 50 V
For Ex applications, observe the ambient temperature range carefully. The FS-LB-I operates from -30°C to +60°C in hazardous areas. Refer to the EC-Type Examination Certificate for specific conditions. CSA approval is also available under control drawing 116-0187 (cCSAus). Additional certificates can be found on the Pepperl+Fuchs website.
Installation Guidelines
The FS-LB-I must connect to a solid and effective ground system. This ground must be at the same equipotential level as the protected instrument. Install the barrier as close as possible to the instrument being protected. Screw the M20 x 1.5 thread into a conduit or cable gland opening.
Key Installation Points for the FS-LB-I:
Ground Connection: Solid, low-impedance earth ground
Equipotential Bonding: Same level as protected instrument
Proximity: Install as close to instrument as possible
Thread Seal: Use PTFE tape for watertight seal
Cable Routing: Keep signal wires away from power cables
Do not install the FS-LB-I without proper grounding verification. The ground system must comply with all applicable local regulations. For floating systems, provide a reference ground connection. Inspect the barrier for damage before each installation. Replace any unit that has survived a major lightning strike.
Environmental Specifications
The FS-LB-I withstands a wide range of operating conditions. Ambient temperature ranges from -30°C to +60°C for standard applications. For Ex applications, refer to the certificate for any restrictions. The IP67 rating allows outdoor installation without additional enclosures.
Operating Temperature (Standard): -30°C to +60°C
Operating Temperature (Ex): Per EC-Type Examination Certificate
Storage Temperature: Same as operating range
Humidity: 0 to 95% non-condensing
Protection: IP67 dust-tight and water-submersible
The stainless steel housing of the FS-LB-I resists chemical corrosion. AISI 316 material withstands salt spray and acidic environments. The polished surface prevents dirt accumulation and eases cleaning. Consequently, this barrier suits offshore platforms and chemical plants perfectly.
Regulatory Compliance
The FS-LB-I complies with multiple international standards. Degree of protection follows IEC 60529:2001 for IP67 rating. ATEX directive 94/9/EC is met with EN 60079-0:2009 and EN 60079-11:2007. CSA approval under control drawing 116-0187 covers North American installations.
Protection Standard: IEC 60529:2001
ATEX Directive: 94/9/EC
EN Standards: 60079-0:2009, 60079-11:2007
CSA: Control drawing 116-0187 (cCSAus)
Surge Test: IEC 60-2 compliant
The FS-LB-I discharge current ratings follow IEC 60-2 standards. Common mode (line to ground) rating is 10 kA. Differential mode (line to line) rating is 5 kA. These ratings ensure robust protection for most industrial installations.
Application Examples
The FS-LB-I is ideal for protecting 4-20 mA transmitters. Pressure, temperature, and flow transmitters benefit from this barrier. It also protects RTD and thermocouple input circuits. The barrier works with both analog and digital field devices.
Typical Applications for the FS-LB-I:
Pressure transmitters in tank farms
Temperature sensors on outdoor vessels
Flow meters in lightning-prone areas
Level transmitters on storage tanks
Valve positioners with analog feedback
The FS-LB-I mounts directly on most process transmitters. Look for an unused M20 x 1.5 conduit opening on the device. Screw the barrier into that opening securely. Then connect the instrument wires through the barrier’s cable. Finally, ground the barrier to the local earth bus bar.
Package Contents
Your purchase of the FS-LB-I includes:
(1) Pepperl+Fuchs Surge Protection Barrier – FS-LB-I
(1) Pre-wired cable assembly (0.4 meters)
(1) Installation instructions leaflet
Frequently Asked Questions (FAQ)
Q: What is the maximum discharge current rating of the FS-LB-I?
A: The FS-LB-I handles 10 kA line to ground (common mode). For line to line (differential), the rating is 5 kA per IEC 60-2.
Q: Is the FS-LB-I suitable for hazardous area installation?
A: Yes, the FS-LB-I carries Ex ia IIC T6 certification. It is approved for Zone 1 and Zone 2 explosive atmospheres.
Q: What is the response time of the FS-LB-I?
A: The FS-LB-I responds in 1 nanosecond for symmetrical surges. Asymmetric surge response time is 100 nanoseconds maximum.
Q: Can the FS-LB-I be used outdoors?
A: Yes, the FS-LB-I has IP67 and stainless steel AISI 316 housing. It resists rain, dust, and temporary submersion.
Q: What voltage rating does the FS-LB-I require?
A: The FS-LB-I operates with rated voltage up to 48V DC. It protects instruments with less than 500V isolation to ground.