+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

FN-LB-I Surge Protection Barrier 1-Channel 20kA SIL 3 ATEX

Introduction:

The FN-LB-I is a single-channel surge protection barrier for field mounting applications. Designed with a ½ NPT thread and stainless steel housing, this barrier withstands harsh industrial environments. With a maximum surge current rating of 20 kA (8/20 µs), it provides robust protection against transient overvoltages. Certified for hazardous area use, the device achieves up to SIL 3 according to IEC/EN 61508.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Beckoff
Series: FN-LB
Part Number: FN-LB-I
Type: Surge Protection Barrier (1-Channel)
Condition: Subject to stock check
Weight: 0.2
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

FN-LB-I Surge Protection Barrier

The FN-LB-I is a single-channel surge protection barrier for field mounting applications. Designed with a ½ NPT thread and stainless steel housing, this barrier withstands harsh industrial environments. With a maximum surge current rating of 20 kA (8/20 µs), it provides robust protection against transient overvoltages. Certified for hazardous area use, the device achieves up to SIL 3 according to IEC/EN 61508.

Technical Specifications of the FN-LB-I

General and Functional Safety

Turning first to functional safety, the FN-LB-I protects one signal line per channel. The Safety Integrity Level (SIL) reaches SIL 3 under IEC/EN 61508 standards. Consequently, this barrier is suitable for safety-critical instrumentation loops requiring high reliability.

Electrical Supply Ratings

Regarding supply specifications, the rated voltage (Ur) is ≤ 48 V. The rated current (Ir) is ≤ 250 mA for normal operation. Leakage current stays below ≤ 5 µA, minimizing signal degradation. On-state voltage reaches ≤ 85 V during surge events. Ground insulation provides ≥ 500 V breakdown voltage protection.

Surge Protection Performance

The total discharge current (8/20 µs) is 20 kA. For line-to-ground (common mode) surges, maximum leakage current is 10 kA. For line-to-line (differential mode) surges, maximum leakage current is 5 kA per IEC 60-2. Nominal response time is 1 ns for symmetrical surges and 100 ns for asymmetrical surges. Bandwidth extends to ≥ 40 kHz, preserving signal integrity for most industrial signals.

Mechanical Specifications

The FN-LB-I housing is constructed of stainless steel 1.4401 (AISI 316). The surface is all over polished for corrosion resistance. Degree of protection is IP67, ensuring dust-tight and water-immersion resistance. Cable length is 0.3 meters. Mass is approximately 200 g. Dimensions are AF22 x 77 mm (0.9 x 3 inches) with width across flats of 22 mm. Mounting uses a ½ NPT thread for direct field installation.

Environmental and Hazardous Area Certifications

Temperature Range

The ambient temperature range is -30°C to 60°C (-22°F to 140°F). For usage in hazardous areas, the EC-type examination certificate must be observed.

ATEX Certification

The FN-LB-I holds EU-type examination certificate PTB 00 ATEX 2175. Marking is 1 II 2G EEx ia IIC T6. This certification permits installation in Zone 2 hazardous areas with gas groups IIC. The voltage Ui is 50 V for intrinsic safety parameters.

Directive Compliance

For Directive 2014/34/EU (ATEX), compliance is demonstrated with EN 60079-0:2012+A11:2013 and EN 60079-11:2012. These standards cover explosion protection requirements.

CSA Approval

CSA approval is documented under control drawing 116-0187 (cCSAus). This permits installation in Canadian and US hazardous locations.

Installation Guidelines for the FN-LB-I

First, mount the FN-LB-I using the ½ NPT thread directly into a junction box or enclosure. Ensure the stainless steel housing is properly grounded to dissipate surge energy. Then, connect the field wiring to the barrier according to your loop diagram. For hazardous area installations, observe the parameters from the EC-type examination certificate. Next, verify that the rated voltage (≤ 48 V) and current (≤ 250 mA) are not exceeded. Finally, test the barrier after installation to confirm proper operation.

Package Contents

  • One (1) FN-LB-I surge protection barrier

  • Pre-wired 0.3 m cable (attached)

  • Installation and certification documentation

Common FAQs for the FN-LB-I

1. What is the SIL rating of the FN-LB-I surge barrier?
The FN-LB-I achieves Safety Integrity Level (SIL) 3 according to IEC/EN 61508. Consequently, it is suitable for safety-critical instrumentation applications.

2. What is the maximum surge current rating?
The FN-LB-I has a total discharge current (8/20 µs) of 20 kA. This provides robust protection against lightning-induced and switching transients.

3. Is this barrier suitable for hazardous area installation?
Yes, the FN-LB-I holds ATEX certification (PTB 00 ATEX 2175) with marking 1 II 2G EEx ia IIC T6. CSA approval is also provided.

4. What is the housing material and protection rating?
The FN-LB-I features a stainless steel 1.4401 (AISI 316) housing with IP67 degree of protection. Therefore, it is dust-tight and submersible.

5. What is the response time of this surge barrier?
Nominal response time is 1 ns for symmetrical surges and 100 ns for asymmetrical surges. Consequently, fast-rising transients are effectively clamped.

Why Choose the FN-LB-I Surge Protection Barrier?

In summary, this single-channel surge protection barrier delivers robust transient protection for field-mounted instrumentation. First, the 20 kA surge current rating handles severe lightning and switching transients. Second, the SIL 3 certification ensures suitability for safety-critical loops requiring high reliability. Third, the stainless steel IP67 housing provides exceptional durability in harsh outdoor and industrial environments. Fourth, the ATEX Zone 2 and CSA approvals permit hazardous area installation. Fifth, the ultra-fast 1 ns response time protects even the most sensitive electronic instruments. Consequently, order the FN-LB-I today for your surge protection requirements in demanding and hazardous locations.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap