+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Allen-Bradley 1746-NT8 | SLC 500 Thermocouple Input Module

Introduction:

Allen-Bradley 1746-NT8 SLC 500 thermocouple/mV analog input module. 8 channels, J/K/T/E/S/R/B/N, 16-bit resolution, cold-junction compensation.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-NT8
Type: Thermocouple/mV Analog Input Module
Condition: Subject to stock check
Weight: 0.42
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Allen-Bradley 1746-NT8 – SLC 500 Thermocouple/mV Analog Input Module

The Allen-Bradley 1746-NT8 is an SLC 500 thermocouple/mV analog input module. Specifically, this module provides eight input channels for temperature and millivolt measurements. It is compatible with J, K, T, E, S, R, B, and N thermocouple sensors. Furthermore, it accepts millivolt signals of ±50 mV and ±100 mV. Consequently, this module suits a wide range of temperature monitoring applications.

Ordering Configuration and Product Identification

  • Manufacturer: Rockwell Automation.

  • Brand: Allen-Bradley.

  • Part Number: 1746-NT8.

  • Series: SLC 500.

  • Module Type: Thermocouple/mV Analog Input Module.

  • Number of Inputs: Eight (8) channels total.

  • I/O Chassis Location: Any slot except Slot 0.

  • Compatibility: Fixed style and modular style SLC 500.

  • UPC: 10611320130888.

  • Therefore, the Allen-Bradley 1746-NT8 installs flexibly in SLC 500 systems.

Thermocouple Sensor Compatibility

  • J Type Thermocouple: Supported.

  • K Type Thermocouple: Supported.

  • T Type Thermocouple: Supported.

  • E Type Thermocouple: Supported.

  • S Type Thermocouple: Supported.

  • R Type Thermocouple: Supported.

  • B Type Thermocouple: Supported.

  • N Type Thermocouple: Supported.

  • Millivolt Signal (Positive/Negative): ±50 mV and ±100 mV.

  • Thus, the 1746-NT8 accommodates nearly all common thermocouple types.

Backplane Power and Current Consumption

  • Backplane Current (5 Volts DC): 120 milliamps.

  • Backplane Current (24 Volts DC): 70 milliamps.

  • Backplane Power Consumption (5V DC): 0.6 Watt.

  • Backplane Power Consumption (24V DC): 1.68 Watt.

  • Total Backplane Power: 2.28 Watts maximum.

  • Operating Temperature: 0 to 60 degrees Celsius.

  • Storage Temperature: -40 to 85 degrees Celsius.

  • Humidity Range: 5-95% non-condensing.

  • Therefore, the Allen-Bradley 1746-NT8 consumes minimal backplane resources.

Resolution and A/D Conversion

  • Resolution: 16 bits input, 14 bits output.

  • A/D Conversion Method: Sigma-delta modulation.

  • Digital Filter Type: Low-pass filter with programmable frequencies.

  • Normal Mode Rejection (50-60 Hz): Greater than 100dB between terminals.

  • Common Mode Rejection (50-60 Hz): Greater than 100dB between inputs and ground.

  • Input Impedance: Greater than 10 M Ohms.

  • External Device Impedance: Less than 100 Ohms required for accuracy.

  • Autocalibration: Every 2 minutes after power up.

  • Consequently, the 1746-NT8 delivers accurate temperature readings with excellent noise rejection.

Update Time and Step Response

  • Update Time Range: 356 milliseconds to 4.05 seconds.

  • Step Response: 60 milliseconds input, 2.5 milliseconds output.

  • Open Circuit Detection: Selectable options (Zero, Upscale, Downscale).

  • Input Overvoltage Protection: ±30V DC and 600W pulsed for 1ms.

  • Input Step Response Time (Overall): 400 milliseconds.

  • Open Circuit Detection Cycle: 1 cycle per channel.

  • Thus, the Allen-Bradley 1746-NT8 provides configurable update speeds for various applications.

Isolation and Protection Specifications

  • Circuit Isolation (Inputs to Chassis Ground): 12.5V DC tested at 500V DC for 1 minute.

  • Circuit Isolation (Inputs to Backplane): 12.5V DC tested at 500V DC for 1 minute.

  • Overvoltage Protection: ±30V DC continuous.

  • Pulsed Protection: 600W for 1 millisecond.

  • Channel Configuration: Independently selectable per channel.

  • Therefore, the 1746-NT8 protects against field wiring faults and transients.

Removable Terminal Block and CJC Sensors

  • Terminal Block Model: 1746-RT34 (Removable Terminal Block).

  • CJC Sensors: Two cold-junction compensation sensors included.

  • CJC Accuracy: ±1.72 degrees Celsius.

  • Connection Type: Removable for easy module replacement.

  • Wiring Benefit: No rewiring needed during module exchange.

  • Field Wiring: Standard thermocouple extension wire.

  • Consequently, the Allen-Bradley 1746-NT8 simplifies installation and maintenance.

LED Indicators and Diagnostics

  • Number of LEDs: 9 green status indicators total.

  • Channel Indicators: One LED for each of 8 channels.

  • Module Status Indicator: One LED for module status.

  • Function: Displays channel activity and module health.

  • Error Detection: Open circuit, under-range, over-range, and channel error.

  • Error Bits: Accessible via HMI or SCADA systems.

  • Troubleshooting: Visual diagnostics without additional tools.

  • Thus, operators can quickly identify channel and module status.

Data Formats and Processor Compatibility

  • Engineering Units: Supported.

  • Scaled for PID: Most compatible format for thermocouple/mV signals.

  • Proportional Counts: Supported.

  • SLC 5/01: Compatible.

  • SLC 5/02: Compatible.

  • SLC 5/03: Compatible.

  • SLC 5/04: Compatible.

  • SLC 5/05: Compatible.

  • Fixed Style Chassis: 1746-A2 chassis supported.

  • Modular Style: Any slot except slot 0 (reserved for processor or communication adapters).

  • Communication Adapters: Remote I/O, Data Highway Plus (DH+), Ethernet.

  • Therefore, the 1746-NT8 works with all SLC 500 processors and chassis styles.

Error Detection and Alarms

  • Open Circuit Detection: Zero, Upscale, or Downscale selectable.

  • Under-Range Detection: Yes, with dedicated error bits.

  • Over-Range Detection: Yes, with dedicated error bits.

  • Channel Error Detection: Yes, with dedicated error bits.

  • Monitoring Access: HMI and SCADA systems can read error bits.

  • Fault Response: Configurable per channel.

  • Consequently, the Allen-Bradley 1746-NT8 enables comprehensive diagnostic monitoring.

Installation Guide

First, verify that SLC 500 system power is completely disconnected. Then, select an available I/O slot for the Allen-Bradley 1746-NT8. Remember that slot 0 is reserved for the processor or communication adapter. After that, remove the 1746-RT34 removable terminal block from the module front. Next, connect your thermocouple or millivolt sensors to the appropriate terminals. Ensure that external device impedance is less than 100 Ohms for accuracy. For thermocouple wiring, use proper extension wire types matching your sensor. Then, verify that the two CJC sensors are properly seated on the terminal block. Subsequently, re-insert the terminal block into the module front. Secure the terminal block using the provided latches. Then, apply power to the SLC 500 system. After that, configure each channel for the correct thermocouple type or millivolt range using your programming software. Select the desired data format (Engineering Units, Scaled for PID, or Proportional Counts). Then, choose the open circuit detection behavior (Zero, Upscale, or Downscale). Finally, monitor the green channel LEDs to verify input signals. As a result, the Allen-Bradley 1746-NT8 will provide accurate temperature measurements.

Packaging List

  • One Allen-Bradley 1746-NT8 thermocouple/mV analog input module

  • One 1746-RT34 removable terminal block (installed)

  • Two cold-junction compensation (CJC) sensors (installed on terminal block)

  • One product identification label

  • One installation and wiring guide

Common FAQs

Q1: What thermocouple types does the Allen-Bradley 1746-NT8 support?
A: This module supports J, K, T, E, S, R, B, and N thermocouple types. Additionally, it accepts ±50 mV and ±100 mV signals. Therefore, it covers nearly all common temperature sensing applications.

Q2: How many channels does the 1746-NT8 provide?
A: This module provides eight analog input channels. Each channel is independently configurable for thermocouple type or millivolt range. Consequently, mixed sensor types can be connected to a single module.

Q3: What is the resolution of the Allen-Bradley 1746-NT8?
A: The resolution is 16 bits for input conversion and 14 bits for output data. The A/D conversion method uses sigma-delta modulation. Thus, it delivers high-precision temperature measurements.

Q4: Does the 1746-NT8 include cold-junction compensation?
A: Yes, two cold-junction compensation (CJC) sensors are included with the 1746-RT34 terminal block. CJC accuracy is ±1.72 degrees Celsius. Therefore, accurate temperature readings are ensured without external compensation.

Q5: What open circuit detection options are available on the 1746-NT8?
A: Three selectable open circuit detection behaviors are available: Zero, Upscale, or Downscale. This selection is configurable per channel. Consequently, you can choose the safest failure response for your application.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap