+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

25A-D030N104 | Allen-Bradley PowerFlex 523 15kW Drive IP20

Introduction:

The Allen-Bradley 25A-D030N104 PowerFlex 523 AC drive delivers 15 kW normal duty (11 kW heavy duty) from 380-480V three-phase input. IP20 open type, panel mount.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen-Bradley
Part Number: 25A-D030N104
Condition: Subject to stock check
Shipping Port: Xiamen

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Evaluating the 25A-D030N104 for Your Application

The Allen-Bradley 25A-D030N104 is a PowerFlex 523 adjustable-frequency AC drive from the PowerFlex 520-series platform, built for demanding environments where dependable motor control is mission-critical. With a 15 kW (20 HP) normal duty rating and 11 kW (15 HP) heavy duty rating at 30 A, this Frame D drive suits pump, fan, and conveyor applications across oil & gas, water treatment, and general industrial settings. This buyer’s guide walks through the specifications that matter most when matching the drive to your process.

Figure 1: Front view of the Allen-Bradley 25A-D030N104 industrial automation component showing its physical design and enclosure.

Key Technical Specifications

  • Input voltage: 380…480V AC, three-phase, with -15%/+10% tolerance and 47…63 Hz input frequency.
  • Output ratings: 15 kW (20 HP) normal duty, 11 kW (15 HP) heavy duty, 30 A continuous.
  • Operating temperature: -20…+50 °C without derating (vertical IP20); up to +70 °C with fan kit.
  • Control methods: Volts/Hertz, sensorless vector control, and Economizer SVC.
  • Efficiency: 97.5% typical, with displacement power factor of 0.98 across the speed range.
  • Enclosure: IP20 NEMA/Open Type, panel mount; IP30/NEMA 1 requires the 25-JBAx option kit.
  • Communication: RS-485 DSI port supporting Modbus RTU; EtherNet/IP via 25-COMM-E2P option card.
  • Overload: Heavy duty 150% for 60 s, 180% for 3 s; normal duty 110% for 60 s, 150% for 3 s.
  • Dimensions: 260.0 H × 130.0 W × 212.0 D mm; weight 3.9 kg (Frame D).

The 97.5% efficiency and 0.98 power factor are particularly relevant for continuous-duty oil & gas processes where energy costs accumulate around the clock. The drive’s internal DC bus choke, standard on this rating, helps smooth input current harmonics and supports stable operation on weaker supply systems.

Operating Temperature and Environmental Considerations

Operating temperature is often the deciding factor in field installations. The 25A-D030N104 is rated for -20…+50 °C ambient in vertical IP20 mounting without derating. Above 50 °C, derating applies up to +60 °C, and the optional 25-FANx-70C control module fan kit extends operation to +70 °C. For installations requiring NEMA 1/UL Type 1 protection, the 25-JBAx kit reduces the without-derating limit to 45 °C. Storage temperature spans -40…+85 °C, and relative humidity tolerance is 0…95% non-condensing. The drive is fan cooled and complies with IEC 60721-3-3 level 3C2 for chemical and gases only, so the ambient atmosphere must be free of volatile or corrosive gases, vapors, or dust. In oil & gas environments, this means the drive should be installed in a suitable enclosure or control room when corrosive atmospheres are present.

Input Voltage, Power Supply, and Electrical Protection

The 380…480V AC three-phase input provides the full rating; applying single-phase input yields only 35% of the rating, so three-phase supply is essential for rated performance. Input frequency tolerance is 47…63 Hz, accommodating generator-fed or unstable supplies common in remote oil & gas sites. The drive tolerates -15%/+10% voltage variation. Protection features include a 100,000 A symmetrical short-circuit rating (determined by the installed fuse or breaker AIC rating), DC bus overvoltage trip at 810 V DC, and undervoltage trip at 390 V DC. Power ride-through of 100 ms and logic control ride-through of 0.5 s minimum (2 s typical) help the drive ride through brief supply dips without nuisance trips. Overcurrent protection is 200% hardware limit and 300% instantaneous fault. Electronic motor overload protection provides Class 10 protection per NEC Article 430, and the drive is UL 508C File 29572 listed. Power dissipation is 387 W at rated load and rated speed.

Control, I/O, and Communication Integration

The standard interface module includes an integral keypad, potentiometer, and LED display for local setup and monitoring. Control I/O includes one dedicated Stop input plus four programmable digital inputs, one isolated analog input (0…10V or 4…20 mA, 10-bit), one programmable Form C relay output, and one non-isolated analog output. A pulse train input (0…100 kHz) shares a programmable digital input. The built-in RS-485 DSI port supports Modbus RTU with function codes 03, 06, and 16; network parameters C123 (data rate 1200…38400 bit/s), C124 (node address 1…247), and C127 (format) are configurable. Communication-loss handling via C125 and C126 allows the drive to fault, coast, stop, or continue at the last command after a configurable timeout. For EtherNet/IP, DeviceNet, PROFIBUS DP-V1, or PROFINET, the appropriate 25-COMM option card is required; the PowerFlex 523 supports one communication card without affecting the drive footprint.

Integration Note: Wiring into fieldbus networks may require an external gateway or connection module. Confirm cable and gateway compatibility with the supplier before commissioning. Only pins 4 and 5 of the RJ45 DSI connector carry network signals; the remaining pins must not be connected. RS-485 networks require termination resistors at each end, and network wiring should be separated from power wires by at least 0.3 m (1 ft), crossing only at right angles.

Reliability and Maintenance in Harsh Environments

Field-proven reliability starts with correct installation. The drive’s fan-cooled design requires unobstructed airflow; in dusty or oily atmospheres, periodic inspection of heatsink fins and fan operation is recommended. The 25A-D030N104 carries c-UL-us listing to UL 508C and CSA C22.2 No. 274, CE marking to EN 61800-3 and EN 61800-5-1, RCM, UKCA, and KC certifications. It is tested to AC156 seismic criteria and complies with SEMI F47 for surge immunity. Note that the drive produces leakage current exceeding 3.5 mA AC, so the protective earthing conductor must comply with local regulations for high-earthing-current equipment. The drive is RoHS compliant and meets or exceeds IE2 efficiency class under Ecodesign Regulation (EU) 2019/1781. For mission-critical oil & gas operations, maintaining spare drives or critical components reduces downtime risk; PetroPartsOnline supplies parts engineered for harsh oil & gas environments.

Buyer’s Guide: Matching the Drive to Your Requirements

When evaluating the 25A-D030N104, consider these decision points:

  • Load type: For variable-torque loads like centrifugal pumps and fans, the 15 kW normal duty rating applies. For constant-torque loads such as positive displacement pumps or conveyors, use the 11 kW heavy duty rating.
  • Ambient temperature: Confirm your enclosure temperature. Above 50 °C, plan for derating or the 25-FANx-70C fan kit.
  • Enclosure rating: The standard IP20 open type suits controlled panels. For NEMA 1/UL Type 1, add the 25-JBAx kit.
  • Network protocol: If Modbus RTU suffices, the built-in RS-485 port works. For EtherNet/IP or other protocols, include the appropriate 25-COMM card.
  • Braking: The integral brake IGBT is standard, but dynamic braking requires an external brake resistor sized for your application.
  • EMC: No integral EMC filter is fitted; external filters provide EN 61800-3 Category C1/C2/C3 compliance as needed.

Contact PetroPartsOnline for parts suited to your application’s requirements and for guidance on option kits, filters, and communication adapters.

Frequently Asked Questions

Q: What is the input voltage and power rating of the 25A-D030N104?

A: The 25A-D030N104 accepts 380…480V AC three-phase input with a tolerance of -15%/+10% and 47…63 Hz. It delivers 15 kW (20 HP) normal duty and 11 kW (15 HP) heavy duty at 30 A continuous output.

Q: What are the operating temperature limits for this drive?

A: In vertical IP20/Open Type mounting, the drive operates from -20…+50 °C without derating, up to +60 °C with derating, and up to +70 °C with the optional 25-FANx-70C control module fan kit.

Q: Does the PowerFlex 523 support EtherNet/IP or encoder feedback?

A: No. The 25A-D030N104 has a built-in RS-485 DSI port for Modbus RTU. EtherNet/IP requires the 25-COMM-E2P option card. No encoder option is supported on the PowerFlex 523.

Q: How does the drive handle communication loss on Modbus networks?

A: Parameter C125 [Comm Loss Action] configures the response: Fault (default), Coast Stop, Stop, or Continue Last. C126 [Comm Loss Time] sets the delay from 0.1 to 60.0 seconds (default 5.0 s).

Q: What is the short-circuit rating and overload capability?

A: Maximum short-circuit rating is 100,000 A symmetrical, determined by the installed fuse or breaker AIC rating. Heavy duty overload is 150% for 60 s and 180% for 3 s; normal duty is 110% for 60 s and 150% for 3 s.

Availability and Support

The Allen-Bradley 25A-D030N104 is an active catalog number with no discontinuation date published. In stock and ready to ship from PetroPartsOnline, this drive is backed by reliable sourcing for critical operations. Contact PetroPartsOnline for parts suited to your application’s requirements.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap