+86 18030005825
No.95, Xiangxing Road, Xiang'an District, Xiamen

Allen-Bradley 1746-NT4 SLC 500 Thermocouple Input Module

Introduction:

The 1746-NT4 is a 4-channel thermocouple/mV input module for SLC 500 systems. It supports J/K/T/E/S/R/B/N thermocouples and ±50/±100 mV signals with 16-bit resolution.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen‑Bradley
Series: SLC 500
Part Number: 1746-NT4
Type: Thermocouple/mV Analog Input Module
Condition: Subject to stock check
Weight: 0.3
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Allen-Bradley 1746-NT4 is a thermocouple/mV analog input module. Specifically, it belongs to the SLC 500 product family. This module provides four (4) channels compatible with multiple thermocouple types and millivolt signals.

The module is compatible with both fixed and modular style SLC 500 systems. Furthermore, it does not require any external power supply. Instead, it receives 5V DC and 24V DC power directly from the backplane. Therefore, it integrates seamlessly into existing SLC 500 installations.

General Specifications

The 1746-NT4 offers versatile thermocouple and mV input capabilities. Below are the core technical details.

  • Manufacturer: Rockwell Automation.

  • Brand: Allen-Bradley.

  • Series: SLC 500.

  • Part Number/Catalog No.: 1746-NT4.

  • Module Type: Thermocouple/mV Analog Input Module.

  • Number of Inputs: Four (4).

  • Channels: 4 backplane isolated.

  • I/O Chassis Location: Any slot except Slot 0.

  • UPC: 10662468165911.

Supported Thermocouple Types

The 1746-NT4 accepts a wide variety of thermocouple sensors. For example, these include types J, K, T, E, S, R, B, and N. Consequently, this single module handles most industrial temperature measurement applications.

Supported Millivolt Signals

In addition to thermocouples, the 1746-NT4 also accepts direct millivolt inputs. Specifically, it supports ±50 mV and ±100 mV ranges. Thus, it suits high-precision low-voltage measurement applications.

Resolution and Conversion

The 1746-NT4 delivers high-resolution analog-to-digital conversion. Its resolution is 16 bits in and 14 bits out. Moreover, it uses sigma-delta modulation for A/D conversion. The bandwidth ranges from 2.62 to 65.5 Hertz. Finally, the update time varies from 26 milliseconds to 1.2 seconds, depending on the filter selection.

Backplane Power Consumption

The 1746-NT4 draws power from both backplane voltages. Its backplane current at 5 Volts is 60 milliamps. Similarly, its backplane current at 24 Volts is 55 milliamps. Total backplane power consumption is 0.8W maximum. This breaks down to 0.3W at 5V DC and 0.5W at 24V DC.

Cold Junction Compensation (CJC)

The 1746-NT4 includes two cold-junction compensation (CJC) sensors. It uses these instead of offset voltages. Hence, thermocouple input signal accuracy is retained without external compensation components.

Auto-Calibration

The 1746-NT4 auto-calibrates at power-up. Additionally, it auto-calibrates whenever a channel is enabled. For this reason, measurement accuracy is maintained without manual calibration.

Open Circuit Detection

The 1746-NT4 features broken sensor detection for each channel. When an open circuit is detected, the module can be configured for one of three behaviors. First, Zero forces the module reading to zero (0). Second, Upscale forces the reading to the maximum value. Third, Downscale forces the reading to the lowest value.

These settings help quickly diagnose the state of each channel. Therefore, the fault reaction should be based on the fail-safe operation of the process.

Input Filter Frequencies

The 1746-NT4 allows individual channel filter selection. This minimizes the effect of electrical noise and AC line fluctuations. Selectable filter frequencies include 250 Hz (minimal noise filtering), 60 Hz (for 60 Hz AC line noise rejection), 50 Hz (for 50 Hz AC line noise rejection), and 10 Hz (maximum noise filtering).

Important Note: If a Cold Junction Compensation (CJC) input is selected, the input filter is ignored.

Step Response and Update Time

The 1746-NT4 has defined timing characteristics. Its step response at 95% ranges from 12 to 300 milliseconds. Meanwhile, its update period ranges from 26 milliseconds to 1.2 seconds. Consequently, the module can be tuned for either fast response or maximum noise rejection.

Block Transfer Requirements

The 1746-NT4 requires block transfers in a remote I/O configuration. Therefore, programming considerations differ between local and remote installations.

LED Indicators

The 1746-NT4 provides clear visual status indication. It has 5 green status indicators in total. One LED indicates overall module status. The remaining four LEDs indicate the status of each channel. Hence, operators can quickly identify module and channel health.

Wiring Specifications

The 1746-NT4 has specific wiring requirements for optimal performance. Use a maximum of two wires per terminal. The maximum wire size is 2.5 millimeters (14 AWG). Additionally, the maximum cable impedance is 25 ohms.

For Thermocouple Inputs: Use shielded twisted thermocouple extension wire.

For mV Inputs: Use Belden 8761 or equivalent wire.

Environmental Specifications

The 1746-NT4 withstands typical industrial conditions. Its operating temperature ranges from 0 to 60°C. Its storage temperature ranges from -40 to 85°C.

Key Features

The 1746-NT4 offers several advantages for temperature and mV measurement applications.

Wide Thermocouple Support:
It accepts J, K, T, E, S, R, B, and N thermocouples. Therefore, one module serves most industrial temperature applications.

Dual mV Ranges:
It supports ±50 mV and ±100 mV inputs. Consequently, it suits high-precision low-voltage measurements.

Built-in Cold Junction Compensation:
Two CJC sensors retain thermocouple accuracy without external components. Hence, installation is simplified.

Auto-Calibration:
It calibrates at power-up and when channels are enabled. For this reason, manual calibration is eliminated.

Configurable Open Circuit Detection:
Zero, upscale, or downscale settings determine fault behavior. Thus, fail-safe operation can be tailored to the process.

Programmable Input Filters:
Selectable frequencies (250 Hz, 60 Hz, 50 Hz, 10 Hz) minimize noise. Consequently, erratic readings due to electrical noise are reduced.

Backplane Isolated Channels:
Four channels with backplane isolation are provided. Therefore, ground loops are minimized.

No External Power Required:
It is powered directly from the SLC 500 backplane. Hence, no separate power supply is needed.

Typical Applications

The 1746-NT4 suits various temperature and mV measurement applications.

  • Thermocouple temperature monitoring in ovens and furnaces.

  • Process temperature measurement in chemical plants.

  • High-precision millivolt signal acquisition.

  • Retrofit upgrades to existing SLC 500 systems.

  • Remote I/O configurations requiring block transfers.

Installation Guidelines

Install the 1746-NT4 in any I/O chassis slot except Slot 0. First, ensure the chassis power supply can provide the required 60 mA at 5V and 55 mA at 24V. Then, insert the module into the slot.

Connect thermocouple sensors using shielded twisted thermocouple extension wire. For mV inputs, use Belden 8761 or equivalent wire. Terminate up to two wires per terminal with a maximum size of 14 AWG. Additionally, ensure cable impedance does not exceed 25 ohms.

Configure each channel for the desired thermocouple type or mV range. Select the appropriate input filter frequency (250 Hz, 60 Hz, 50 Hz, or 10 Hz). For CJC inputs, the filter is ignored. Finally, set the open circuit detection behavior (Zero, Upscale, or Downscale) based on process fail-safe requirements.

For remote I/O configurations, block transfers are required. The module auto-calibrates at power-up and when channels are enabled.

What is in the Box

Please inspect all items upon delivery.

  • Allen-Bradley 1746-NT4 thermocouple/mV input module.

  • Installation instruction manual.

Frequently Asked Questions (FAQ)

1. How many input channels does the 1746-NT4 have?

The 1746-NT4 provides four (4) analog input channels. Each channel can be independently configured for thermocouple or mV input.

2. What thermocouple types does this module support?

The 1746-NT4 supports J, K, T, E, S, R, B, and N thermocouple types. Therefore, it covers most industrial temperature measurement needs.

3. What open circuit detection options are available?

The 1746-NT4 offers three open circuit detection behaviors. Zero forces the reading to 0. Upscale forces the reading to maximum. Downscale forces the reading to minimum. The fault reaction should be based on process fail-safe requirements.

4. Can this module be installed in slot 0 of the SLC 500 chassis?

No. The 1746-NT4 can be installed in any I/O chassis slot except Slot 0. Slot 0 is typically reserved for the CPU or power supply.

5. Does this module require an external power supply?

No. The 1746-NT4 receives 5V DC and 24V DC power directly from the SLC 500 backplane. Hence, no external power supply is required.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap