ATV930U22N4Z | Schneider Electric 2.2 kW Drive IP20



Introduction:
The ATV930U22N4Z is a dual-rated 2.2 kW/1.5 kW variable speed drive from Schneider Electric's Altivar Process ATV930 series, built for cabinet integration in demanding oil and gas operations.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
When a Pump Jack Demands More Than a Standard Drive Can Deliver
A common challenge in oil and gas pumping stations is matching motor output to changing load conditions without sacrificing reliability. The Schneider Electric ATV930U22N4Z variable speed drive addresses this by offering dual ND/HD ratings in a single cabinet-mount package. This three-phase drive operates from a 380…480 V supply and delivers 2.2 kW in normal duty or 1.5 kW in heavy duty, making it a rugged choice for mission-critical applications.
The ATV930U22N4Z belongs to the Altivar Process ATV930 series, engineered for harsh environments. Its IP20 protection rating and integrated Category C2 EMC filter simplify panel integration while maintaining dependable performance.

Key Technical Specifications of This unit
- Supply voltage: 380…480 V three-phase (-15%/+10%), 50/60 Hz
- Motor power (ND): 2.2 kW (3 HP), 120% overload for 60 s
- Motor power (HD): 1.5 kW (2 HP), 150% overload for 60 s
- Output frequency: 0.1…599 Hz
- Operating temperature: 0 to +40 °C standard, derating to 50 °C
- Protection rating: IP20 (bottom power terminals IP00)
- Dimensions (H×W×D): 285 x 130 x 196 mm
- Integrated safety: STO function, SIL3 / Cat. PL e
- Built-in ports: Ethernet dual-port switch (RJ45); Modbus serial port (RJ45)
- EMC filter: Category C2 integrated
These parameters highlight the drive’s ability to handle demanding loads while maintaining a compact footprint. The dual rating allows engineers to select the appropriate overload profile for their specific application, whether it involves constant torque or variable torque loads.
Applications and Use Cases in Oil & Gas
In upstream operations, This unit can control progressive cavity pumps where torque demands fluctuate with fluid viscosity. Its heavy-duty rating provides the extra margin needed during start-up or temporary blockages. For midstream compressor stations, the drive’s 0.1…599 Hz output frequency range supports precise speed regulation. Additionally, the integrated STO safety function enables safe maintenance procedures without power isolation, a critical feature for mission-critical processes. The drive’s environmental class 3C3 / 3S3 / 3M3 ensures reliable operation in corrosive and humid conditions often found in field installations.

Installation and Setup Guidance
Proper installation is essential for reliable performance. This unit requires a minimum clearance of 100 mm above and below, and 10 mm in front, to ensure adequate airflow. The required minimum air flow is 38 m3/h. Terminal tightening torque for frame 1-3 power terminals is 2.5 N·m. When integrating into a cabinet, verify that the ambient temperature does not exceed 40 °C without derating. The drive’s built-in braking unit requires an external braking resistor with a minimum resistance of 56 Ω. For detailed wiring and configuration, refer to the official installation manual NHA80932.
Maintenance and Reliability
Regular inspection of cooling fans and heat sink fins helps prevent overheating in dusty environments. Because the drive operates in ambient temperatures up to 50 °C with derating, monitoring cabinet temperature is advisable. This unit is built for demanding environments, with an environmental class rating that covers mechanical vibration and corrosive gases. Its Achilles Level 2 cybersecurity certification adds a layer of protection for networked operations. Following a preventive maintenance schedule will help ensure reliability you can depend on.
Compatibility and Integration
The drive includes built-in EtherNet/IP and Modbus TCP protocols via a dual-port Ethernet switch, simplifying connection to plant control systems. An option slot accepts fieldbus modules for PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT, or POWERLINK. Up to three additional I/O modules can be added for expanded analog and digital connectivity. Integration Note: wiring into such networks may require an external gateway or connection module; confirm cables and gateways with the supplier.
Frequently Asked Questions
What is the motor power rating of This unit?
This unit delivers 2.2 kW (3 HP) in normal duty with 120% overload for 60 s, or 1.5 kW (2 HP) in heavy duty with 150% overload for 60 s.
Can This unit operate at temperatures above 40 °C?
Yes, the drive supports operation up to 50 °C with derating from 40 to 50 °C, as specified in the catalog.
What is the supply voltage for This unit?
The drive accepts a three-phase supply of 380…480 V (-15%/+10%) at 50/60 Hz.
Does This unit include a braking resistor?
No, the drive has a built-in dynamic brake transistor but requires an external braking resistor with a minimum resistance of 56 Ω.
What safety function is integrated into This unit?
It includes a Safe Torque Off (STO) function certified to SIL3 / Cat. PL e, providing a high level of functional safety.
For parts suited to your application’s requirements, contact PetroPartsOnline.