DS50-P1112 | SICK 10 m HDDM Laser Distance Sensor

Introduction:
The SICK DS50-P1112 is a rugged laser distance sensor with a 10 m range, dual PNP outputs, and IP65 housing for dependable oil and gas automation.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
What the SICK DS50-P1112 Laser Distance Sensor Delivers
The SICK DS50-P1112 is a switching laser distance sensor from the Dx50 family. It uses HDDM™ optical time-of-flight measurement to detect natural objects at ranges up to 10,000 mm. Consequently, engineers can replace mechanical limit switches with a non-contact device that reduces wear and maintenance cost. The sensor also carries part number 1047402 for ordering clarity.
In oil and gas operations, unplanned downtime carries a high cost per hour. Therefore, a dependable sensor with a wide operating temperature range and protected electronics helps protect throughput. This unit is built for demanding environments and supports mission-critical positioning tasks.

Key Features and Technical Specifications
- Measurement principle: HDDM™ optical time-of-flight for stable distance readings on natural surfaces.
- Measuring range: 200 mm to 10,000 mm at 90% remission; 6,000 mm at 18%; 4,000 mm at 6%.
- Light source: Visible red laser diode at 658 nm, Class 2 per IEC 60825-1:2014.
- Response time: Fast setting 10 ms; Slow setting 50 ms with averaging.
- Repeatability: ≥ 2.5 mm for consistent switching decisions.
- Switching frequency: Up to 50 Hz for moderate-speed process feedback.
- Digital outputs: Two PNP outputs (Q1 and Q2) rated ≤ 100 mA, short-circuit protected.
- Supply voltage: DC 10 V to 30 V with reverse-polarity protection.
- Power consumption: ≤ 2.1 W without external load.
- Electrical connection: Male M12, 5-pin connector for quick field replacement.
- Enclosure rating: IP65 per EN 60529, suitable for dusty and washdown-prone areas.
- Housing: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window.
- Dimensions: 36.1 mm x 62.7 mm x 57.7 mm; weight approximately 200 g.
- Operating temperature: -30 °C to +65 °C standard; up to +80 °C with two cooling plates; up to +140 °C with two cooling plates and protection filter (Uv ≤ 24 V).
- Storage temperature: -40 °C to +75 °C.
Each specification above has a direct cost or efficiency implication. For example, the 10 ms fast response time shortens control-loop latency and can reduce scrap during high-speed positioning. Additionally, the IP65 housing lowers cleaning and replacement costs in dirty process areas.
Cost and Efficiency Implications of This unit Design
First, the wide DC 10 V to 30 V input range simplifies integration with existing 24 V control cabinets. As a result, plants avoid extra power supplies and wiring changes. Second, the ≤ 2.1 W power consumption reduces heat load inside enclosures, which extends the life of nearby electronics. Third, the adjustable switching hysteresis from 1 mm to 9,999 mm lets engineers tune the sensor to ignore process noise. Consequently, nuisance trips and associated downtime decrease.
Moreover, the zinc die-cast housing and PMMA window resist mechanical impact and chemical exposure common in oil and gas sites. The M12 connector enables fast swap-out during maintenance, cutting labor hours per repair. Finally, the dual PNP outputs can drive two independent control actions, which may eliminate the need for a second sensor in some applications.
Applications in Oil and Gas Automation
This unit suits position monitoring on pipe handling equipment, valve position feedback, and presence detection on conveyors. In tank farms, it can verify the position of floating roof seals without contact. Because the sensor measures natural objects, reflective targets are not required, which reduces installation cost. For high-temperature zones, the optional cooling plates extend the operating range to +140 °C, protecting the sensor investment in heat-intensive processes.
Installation and Integration Guidance
Mount the sensor using its compact 36.1 mm x 62.7 mm x 57.7 mm body and secure the M12 connector firmly. Ensure the supply voltage stays within DC 10 V to 30 V and observe reverse-polarity protection. The two PNP outputs can connect directly to PLC digital inputs. For network integration, note that wiring into fieldbus systems may require an external gateway or connection module; confirm cables and gateways with the supplier. Also, verify that the ambient temperature at the mounting location does not exceed +65 °C without cooling accessories.
Maintenance and Reliability
Inspect the PMMA optical window periodically for dust or oil film, because contamination reduces measurement accuracy. Clean the window with a soft cloth and approved lens cleaner; do not use abrasive materials. Check the M12 connector for tightness and corrosion during scheduled shutdowns. The rugged zinc die-cast housing resists vibration, but mounting hardware should be re-torqued per site standards. These practices support reliability you can depend on and lower total cost of ownership.
Frequently Asked Questions
What is the maximum measuring range of This unit?
The SICK unit measures up to 10,000 mm on objects with 90% remission. For 18% remission, the range is 6,000 mm; for 6% remission, it is 4,000 mm.
Can This unit operate in high-temperature areas?
Yes. The standard operating temperature is -30 °C to +65 °C. With two cooling plates, the range extends to +80 °C; with two cooling plates and a protection filter, it reaches +140 °C (Uv ≤ 24 V).
What is the supply voltage requirement for This unit?
The sensor requires DC 10 V to 30 V and includes reverse-polarity protection. Power consumption is ≤ 2.1 W without external load.
How does This unit connect to a control system?
It uses a male M12, 5-pin connector. Two PNP outputs (Q1 and Q2) can drive PLC inputs directly. For fieldbus networks, an external gateway may be required; confirm with the supplier.
What maintenance does This unit need?
Periodically inspect the PMMA window and clean it gently. Check the M12 connector for tightness. Follow the manufacturer’s safety manual for laser Class 2 precautions.
Contact PetroPartsOnline for parts suited to your application’s requirements.