DL100-23AA2101 | SICK 300 m SSI Laser Sensor



Introduction:
The SICK DL100-23AA2101 is a long-range laser distance sensor with SSI output, 0.15 m to 300 m range, and ±2 mm accuracy for rugged positioning tasks.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
From Mechanical Stops to Optical Precision
For decades, crane and storage-retrieval systems relied on mechanical stops and encoders that drift under vibration. The SICK DL100-23AA2101 represents the next step in that evolution: a phase-shift optical time-of-flight laser distance sensor that measures up to 300 m on Diamond Grade reflective tape.
Built for demanding environments, this Dx100-series sensor delivers repeatability of 0.5 mm to 1 mm and typical accuracy of ±2 mm to ±3 mm. It communicates over an SSI (Synchronous Serial Interface, Gray / Binary code) fieldbus link.

Key Features and Technical Specifications
- Measurement Principle: Phase shift optical time-of-flight laser distance measurement.
- Measuring Range: 0.15 m to 300 m on Diamond Grade reflective tape.
- Light Source: Visible red laser diode at 658 nm, Class 2 per IEC 60825-1:2014.
- Repeatability: 0.5 mm to 1 mm, typical 0.5 mm at 1 σ.
- Measurement Accuracy: Typ. ±2 mm to ±3 mm.
- Maximum Tracking Velocity: 15 m/s.
- Maximum Acceleration: 15 m/s².
- Output Time / Measurement Cycle: ≥ 1 ms; continuous internal rate 1 ms, fieldbus cycle dependent.
- Supply Voltage: DC 18 V to 30 V, reverse-polarity protected.
- Power Consumption: Typ. 8 W to 10 W.
- Ambient Temperature, Operation: -20 °C to +55 °C.
- Ambient Temperature, Storage: -40 °C to +75 °C.
- Enclosure Protection Rating: IP65 per EN 60529.
- Housing Material: Aluminum die-cast with acrylic glass (PMMA) optical window.
- Device Weight: Approx. 800 g.
- Electrical Connection: Power via male M12 4-pin (A-coded, SPEEDCON™); SSI bus via female M12 8-pin.
- Communication Protocol: SSI (Synchronous Serial Interface, Gray / Binary code).
- Continuous Condition Monitoring: Signal level attenuation, laser diode aging, and temperature tracking.
The rugged aluminum die-cast housing and IP65 rating make the DL100-23AA2101 suitable for dusty or wet industrial areas. Meanwhile, the integrated LC display and optical 3-axis alignment bracket compatibility simplify commissioning.
Why Choose This unit Over a Proximity Probe Alternative?
Traditional proximity probes are often limited to short ranges and require frequent adjustment. In contrast, This unit offers a measuring range of 0.15 m to 300 m, making it a practical proximity probe alternative for long-travel axes. Its SSI interface provides deterministic position feedback for controllers.
Additionally, the sensor’s maximum tracking velocity of 15 m/s and acceleration of 15 m/s² support high-speed automated storage and retrieval systems (ASRS). For engineers seeking a proximity probe equivalent with extended range, this model delivers field-proven performance.

Applications and Use Cases
Typical applications include crane positioning, ASRS aisle mapping, and long-range material handling. The sensor’s ability to measure on Diamond Grade reflective tape ensures reliable operation even at 300 m. Furthermore, the continuous condition monitoring feature tracks signal attenuation and laser diode aging, which helps predict maintenance needs.
Because This unit operates from -20 °C to +55 °C, it suits outdoor or unheated warehouse environments. The IP65 enclosure protects against dust and water jets, extending service life in harsh conditions.
Installation and Integration Notes
Mount the sensor using the optical 3-axis alignment bracket for precise aiming at the reflective tape. Power the unit through the M12 4-pin connector with a DC 18 V to 30 V supply. Connect the SSI bus via the M12 8-pin connector.
Integration Note: Wiring into SSI networks may require an external gateway or connection module. Confirm cables and gateways with PetroPartsOnline for your specific control system. The integrated LC display assists with menu navigation during setup.
Maintenance and Reliability
Inspect the PMMA optical window periodically for dust or debris, especially in dirty industrial settings. The condition monitoring function reports signal level attenuation and laser diode aging, allowing planned maintenance. Operate the sensor within the specified ambient temperature range to avoid measurement drift.
With no moving parts in the measurement path, This unit offers reliability you can depend on. The die-cast aluminum housing resists mechanical stress, and the IP65 rating simplifies washdown procedures.
Frequently Asked Questions
What is the measuring range of the SICK unit?
The SICK unit measures from 0.15 m up to 300 m when using Diamond Grade reflective tape.
Can This unit serve as a proximity probe alternative?
Yes, This unit is a proximity probe alternative for applications requiring longer range and SSI output. Its 0.15 m to 300 m range and ±2 mm to ±3 mm accuracy suit many positioning tasks.
What is the supply voltage and power consumption of this sensor?
The sensor operates on DC 18 V to 30 V and consumes typically 8 W to 10 W.
What is the operating temperature range of This unit?
The operating ambient temperature range is -20 °C to +55 °C, with storage from -40 °C to +75 °C.
Which communication protocol does This unit use?
It uses SSI (Synchronous Serial Interface, Gray / Binary code) for fieldbus communication.
Contact PetroPartsOnline for parts suited to your application’s requirements.