DL100-23AA2102 | SICK 300 m Laser Distance Sensor



Introduction:
The SICK DL100-23AA2102 is a PROFIBUS DP laser distance sensor with a 0.15 m to 300 m range on Diamond Grade tape, built for rugged positioning tasks.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
What is the SICK DL100-23AA2102?
The SICK DL100-23AA2102 is a phase-shift optical time-of-flight laser distance sensor from the Dx100 series. It measures up to 300 m on Diamond Grade reflective tape and communicates over PROFIBUS DP at up to 12 Mbit/s. This field-proven sensor is built for demanding environments, including oil and gas logistics and automated storage systems.
This unit delivers dependable long-range positioning with a typical accuracy of ± 2 mm to ± 3 mm. Its rugged aluminum die-cast housing and IP65 rating ensure reliability in harsh industrial settings. For engineers seeking a proximity probe alternative, this sensor offers a non-contact, high-speed solution for critical position feedback.

Key Features and Technical Specifications
- Measurement Principle: Phase shift optical time-of-flight laser distance measurement.
- Measuring Range: 0.15 m to 300 m on Diamond Grade reflective tape.
- Light Source: Visible red laser diode, 658 nm, Class 2 (< 1 mW).
- Measurement Accuracy: Typ. ± 2 mm to ± 3 mm.
- Repeatability: 0.5 mm to 1 mm (typical 0.5 mm at 1 σ).
- Maximum Tracking Velocity: 15 m/s.
- Maximum Acceleration: 15 m/s².
- Output Time: ≥ 1 ms (continuous internal measurement rate 1 ms).
- Supply Voltage: DC 18 V to 30 V (reverse-polarity protected).
- Power Consumption: Typ. 8 W to 10 W.
- Communication Interface: PROFIBUS DP (EN 50170, up to 12 Mbit/s).
- Digital Outputs: 2x push-pull (PNP/NPN, configurable B/Q, ≤ 100 mA).
- Multifunctional Input: MF input available.
- Electrical Connection: Power: male M12 4-pin; PROFIBUS: 2x female M12 5-pin (B-coded, SPEEDCON™).
- Ambient Temperature, Operation: -20 °C to +55 °C.
- Ambient Temperature, Storage: -40 °C to +75 °C.
- Enclosure Protection Rating: IP65 (EN 60529).
- Housing Material: Aluminum die-cast with acrylic glass (PMMA) optical window.
- Dimensions (W x H x D): 69.4 mm x 82.5 mm x 100.2 mm.
- Weight: Approx. 800 g.
This unit stands out with its integrated LC display and optical 3-axis alignment bracket compatibility. These features simplify setup and maintenance in the field. Continuous condition monitoring tracks signal level attenuation, laser diode aging, and temperature, providing early warnings for proactive maintenance.
How Does This unit Compare to Proximity Probes?
When considering a proximity probe alternative, engineers should evaluate range, accuracy, and environmental robustness. This unit offers distinct advantages for long-range applications.
- Measuring Range: This unit covers up to 300 m, while typical proximity probes are limited to a few millimeters.
- Non-Contact Measurement: Laser distance measurement avoids wear and mechanical interference, unlike contact probes.
- Communication: PROFIBUS DP integration enables seamless connection to control systems, whereas proximity probes often require analog interfaces.
- Environmental Rating: IP65 housing and wide temperature range (-20 °C to +55 °C) suit harsh oil and gas environments.
- Diagnostics: Integrated condition monitoring provides predictive maintenance data not typically available in proximity probes.
For applications requiring precise, long-range position feedback in rugged conditions, This unit is a dependable choice. It is not a direct replacement for all proximity probe applications, but it excels where non-contact measurement and network integration are needed.

Applications and Use Cases
The SICK unit is ideal for automated storage and retrieval systems (ASRS), where high acceleration and tracking velocity are essential. Its 15 m/s² acceleration and 15 m/s velocity support fast, accurate positioning of stacker cranes and shuttles. In oil and gas facilities, the sensor can monitor tank levels or crane positions over long distances, leveraging its 300 m range on reflective tape.
Additionally, the PROFIBUS DP interface allows integration into existing control networks, reducing wiring complexity. The IP65 rating and -20 °C to +55 °C operating temperature range ensure reliable performance in outdoor or washdown environments. For mission-critical operations, This unit provides reliability you can depend on.
Installation and Integration
Mounting This unit is straightforward with its optical 3-axis alignment bracket compatibility. The integrated LC display aids in precise alignment and configuration. Power is supplied via a male M12 4-pin connector, while PROFIBUS connections use two female M12 5-pin connectors (B-coded, SPEEDCON™). Ensure the supply voltage is within DC 18 V to 30 V and respect the reverse-polarity protection.
For PROFIBUS integration, configure the sensor as a DP slave according to the network settings. The two push-pull digital outputs can be configured as PNP or NPN and used for limit signaling or error indication. The multifunctional input allows additional control options. Always follow the manufacturer’s guidelines for cable routing and grounding to maintain signal integrity.
Maintenance and Reliability
This unit is designed for low maintenance, but periodic inspection is recommended. Check the PMMA optical window for dust or debris and clean it with a soft cloth and mild detergent. Verify the alignment bracket remains secure, especially in high-vibration environments. The continuous condition monitoring feature reports signal attenuation, laser diode aging, and temperature trends, enabling predictive maintenance before failures occur.
Operate the sensor within the specified ambient temperature range of -20 °C to +55 °C to ensure longevity. The IP65 enclosure protects against dust and water jets, but avoid direct high-pressure washing. Regular diagnostics via PROFIBUS can help identify performance degradation early, supporting reliable operation in demanding environments.
Frequently Asked Questions
What is the measuring range of the SICK unit?
This unit measures from 0.15 m up to 300 m when using Diamond Grade reflective tape.
Can This unit operate in harsh oil and gas environments?
Yes, This unit has an IP65 rating and operates from -20 °C to +55 °C, making it suitable for rugged industrial conditions.
What is the supply voltage for This unit?
The sensor requires a DC supply voltage between 18 V and 30 V and includes reverse-polarity protection.
Is This unit a suitable proximity probe alternative?
For long-range, non-contact position measurement with PROFIBUS DP, This unit can serve as a proximity probe alternative. However, evaluate application-specific requirements.
How does This unit communicate with control systems?
It uses PROFIBUS DP (EN 50170) at up to 12 Mbit/s, with M12 connectors for easy integration.