T9402 Isolated 24V DC Digital Input Module for TMR Systems

Introduction:

The T9402 is a 16‑channel isolated digital input module built for Triconex TMR safety systems. It accepts 0–32V DC inputs, runs on 18–32V DC backplane power, and provides fast scan times for reliable monitoring in critical applications.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Allen-Bradley
Series: Triconex TMR / ICS Triplex
Part Number: T9402
Type: Digital Input Module
Condition: In Stock
Origin: U.S.A
Weight: 0.34 kg
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry
The T9402 digital input module delivers accurate and fast signal detection for safety‑critical industrial control systems.

This 16‑channel isolated design ensures high noise immunity and protects against ground loops in harsh environments.

It supports simplex, dual, and triple redundant modes to meet different safety and availability requirements.

Ultra‑fast module scan times enable real‑time status monitoring for valves, switches, and other field devices.

The T9402 draws power directly from the system backplane with a wide industrial voltage input range.

Its efficient design keeps power usage and heat generation low for continuous, reliable operation.

Full channel isolation enhances system stability and protects the main controller from electrical disturbances.

This module is engineered for long service life in heavy‑duty process and safety control applications.

Technical Specifications

The T9402 is a 16‑channel isolated digital input module for ICS Triplex Triconex TMR platforms.

It supports simplex, dual, and triple redundant operating modes for flexible system design.

Simplex scan time is 0.924 ms for extremely fast single‑channel input monitoring.

Dual redundant scan time is 1.676 ms for improved reliability in critical applications.

Triple redundant scan time is 2.453 ms for maximum fault tolerance and safety performance.

Backplane voltage range is 18–32V DC, compatible with standard industrial power systems.

Maximum backplane current consumption is 260 mA under full load operation.

Input electrical rating is 0–32V DC at 6.5 mA per channel for safe field device connection.

Total power consumption of the T9402 is 4.0 W for energy‑efficient performance.

Heat dissipation is 4.0 W, equivalent to 13.6 BTU per hour during continuous operation.

Module weight is 340 grams (12 ounces), supporting compact and dense chassis installation.

Each input channel is fully isolated to improve noise resistance and prevent cross‑channel interference.

Installation Guide

Install the T9402 into a compatible Triconex chassis backplane in a clean, dry location.

Ensure the backplane provides a stable 18–32V DC power supply before system power‑up.

Connect field digital devices such as switches and sensors to the isolated input terminals.

Check all wiring connections to avoid short circuits and unwanted ground loops.

Fully seat and lock the module to guarantee reliable backplane communication.

Power on the system and verify module status for correct initialization.

Configure the module for simplex, dual, or triple mode based on system safety requirements.

Confirm input signal levels fall within the 0–32V DC operating range for accurate detection.

Provide adequate ventilation around the module to maintain safe operating temperatures.

Protect the unit from dust, moisture, and extreme temperatures during normal operation.

Packing List

  • 1 × Allen-Bradley ICS Triplex T9402 Digital Input Module
  • 1 × Installation and Specification Sheet
  • Anti‑static protective bag
  • Product identification label
Shipping methods: FedEx, UPS, DHL.

Frequently Asked Questions

1. How many input channels does the T9402 have?

The T9402 provides 16 isolated digital input channels for field device monitoring.

2. What is the simplex scan time of the T9402 module?

The simplex scan time of the T9402 is 0.924 ms for high‑speed response.

3. What voltage range does the T9402 support?

The module uses an 18–32V DC backplane and accepts 0–32V DC input signals.

4. How much power does the T9402 consume?

The T9402 consumes a total of 4.0 W during normal operation.

5. Is the T9402 designed for TMR safety systems?

Yes, the T9402 is purpose‑built for Triconex TMR fault‑tolerant safety control systems.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: sales@ubestplc.com

Contact: Klaus

 

Scan the QR code

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap