Honeywell CC-PDIS01 Digital Input SOE | 32 Channels | 1ms Resolution


Introduction:
Honeywell CC-PDIS01 Digital Input SOE Module with 32 channels. Supports 1ms resolution, 24VDC, open wire detection, and redundancy.
Customer Reviews
UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Product Attributes:
Notice: For real-time prices and inventory, please click the button below to contact us.
Honeywell CC-PDIS01 Digital Input SOE Module Overview
The Honeywell CC-PDIS01 is a high-performance Digital Input Sequence of Events module. It belongs to the Honeywell Series C I/O family. This module accepts 24VDC discrete signals as digital inputs. The CC-PDIS01 can time-tag inputs with 1ms resolution for event sequencing. It offers three flexible operating modes for different application needs.
Technical Specifications
Input Channel Characteristics
The CC-PDIS01 provides 32 digital input channels per module. Input channel scanning in Normal mode runs at 20ms PV scan. In Low Latency mode, scanning runs at 5ms PV scan. The digital input resolution for Sequence of Events is 1ms for precise timing. Galvanic isolation reaches 1500 VAC RMS or ±1500 VDC from input terminals to common. The isolation technique uses optical isolation inside the IOM.
Voltage and Current Ratings
The CC-PDIS01 operates with a DI power voltage range of 18 to 30 VDC. ON sense voltage requires a minimum of 13 VDC. ON sense current requires a minimum of 3 mA. OFF sense voltage stays at a maximum of 5 VDC. OFF sense current stays at a maximum of 1.2 mA. Input impedance measures 4.2 KΩ for consistent performance.
Field Wiring Requirements
The CC-PDIS01 needs specific field resistance values for reliable operation. Field resistance for guaranteed ON condition is 300 Ω maximum at 15 VDC. Field resistance for guaranteed OFF condition is 30 KΩ minimum at 30 VDC. Absolute delay across input filter and isolation is 5 ms ± 20%.
Operating Modes
The CC-PDIS01 supports three distinct operating modes. Normal mode provides 20ms PV scan for standard applications. Sequence of Events mode delivers 1ms resolution SOE with 20ms PV scan. Low Latency mode offers 5ms PV scan for fast response requirements.
Notable Features
The CC-PDIS01 includes extensive internal diagnostics for data integrity. Open wire detection works in Normal mode only. The module supports optional redundancy for critical applications. You can select internal or external field power. Onboard excitation power eliminates the need for marshalling power. The module supplies non-incendive field power for safety. Direct or reverse input indication allows flexible configuration. Galvanic isolation protects your control system from field noise.
Open Wire Detection
The CC-PDIS01 can detect and annunciate an open field wire condition. A channel diagnosed with an open wire provides a status of invalid. This feature prevents incorrect control action from bad PV values.
IOTA Compatibility
The CC-PDIS01 works with multiple IOTA termination assemblies. CC-TDIL01 supports non-redundant 9″ applications. CC-TDIL11 supports redundant 12″ applications. CC-GDIL11 provides redundant 12″ support. CC-GDIL21 offers non-redundant 6″ support. CC-GDIL01 supports redundant 12″ for expansion. CC-SDXX01 works with GI-IS I/O Expander 12″ systems.
Installation Guidelines
Always disconnect power before installing the CC-PDIS01 module. Select the appropriate IOTA for your redundancy requirements. Mount the IOTA in your Experion rack or cabinet. Insert the CC-PDIS01 into the designated slot on the IOTA. Connect 24VDC field power to the DI power terminals. Wire each input channel to your field devices. Select internal or external field power via jumper settings. Configure the operating mode in your control software. Verify open wire detection settings for Normal mode. Apply power and check module status indicators.
Package List
One CC-PDIS01 Digital Input SOE Module
One IOTA-specific terminal label set
Basic installation instruction sheet
Common FAQs
1. What is the SOE resolution of the CC-PDIS01?
The CC-PDIS01 provides 1ms resolution for Sequence of Events. This allows precise time-tagging of input changes.
2. Does the CC-PDIS01 support open wire detection?
Yes, the CC-PDIS01 supports open wire detection in Normal mode only. A detected open wire marks the PV as invalid.
3. Can I use the CC-PDIS01 in a redundant configuration?
Yes, the CC-PDIS01 supports optional redundancy. Use IOTA models CC-TDIL11, CC-GDIL11, or CC-GDIL01 for redundancy.
4. What are the three operating modes on the CC-PDIS01?
The CC-PDIS01 offers Normal mode (20ms), Sequence of Events mode (1ms SOE), and Low Latency mode (5ms PV scan).
5. Does the CC-PDIS01 provide onboard field power?
Yes, the CC-PDIS01 supplies onboard excitation power. It also provides non-incendive field power without marshalling power.