Honeywell CC-PDIL51 Digital Input 24VDC Module 32 Ch

Introduction:

Honeywell CC-PDIL51 digital input module for 24VDC signals. 32 channels with open wire detection and galvanic isolation.

ubest aotomation    Customer Reviews

UBEST Automation – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

Product Attributes:

Manufacturer: Honeywell
Series: Experion LX / Series C I/O
Part Number: CC-PDIL51
Type: Digital Input Module
Condition: Subject to stock check
Weight: 0.35
Shipping Port: Xiamen
Warranty: One year

Notice: For real-time prices and inventory, please click the button below to contact us.

Description
Inquiry

Product Overview

The Honeywell CC-PDIL51 is a digital input module for 24VDC signals. It accepts discrete inputs from field devices like sensors and switches. This module belongs to the Honeywell Experion LX or C300 control system family. You get extensive internal diagnostics for complete data integrity. The Honeywell CC-PDIL51 supports optional redundancy for critical applications.

Series: Experion LX / Series C I/O
Product Type: Digital Input Module
Product Category: I/O Modules
Current Price (RMB): ¥3,250
Gross Weight: 0.35 kg


Technical Specifications

The Honeywell CC-PDIL51 provides 32 input channels on one module. Each channel accepts 24VDC signals with clear ON and OFF thresholds.

Input / Output Model Identity

  • Model: CC-PDIL51 – 24 Volt Digital Input

  • Non-Redundant IOTA Model: CC-TDIL51 (9 inch)

  • Redundant IOTA Model: CC-TDIL61 (12 inch)

Channel & Isolation Specifications

  • Input Channels: 32

  • Galvanic Isolation (any input terminal to common): 1000 VAC RMS

  • Isolation Technique: Optical (in IOM)

Power & Voltage Range

  • DI Power Voltage Range: 18 to 30 VDC

  • ON Sense Voltage: 13 VDC minimum

  • ON Sense Current: 3 mA minimum

  • OFF Sense Voltage: 5 VDC maximum

  • OFF Sense Current: 1.2 mA maximum

Input Impedance & Response

  • Input Impedance: 4.2 KΩ

  • Absolute Delay (Input Filter + Isolation): 5 ms ± 20%

Field Resistance Conditions

  • Field Resistance for Guaranteed ON: 300 Ω maximum at 15 VDC

  • Field Resistance for Guaranteed OFF: 30 KΩ minimum at 30 VDC


Key Features & Benefits

The Honeywell CC-PDIL51 includes NO open wire detection for safety. You can select internal or external field power as needed. This module supplies non-incendive field power to devices. It provides onboard excitation power without marshalling power. You get direct or reverse input indication flexibility. The CC-PDIL51 has galvanic isolation rated at 1000 VAC RMS. Optional redundancy improves system availability for critical processes.


Installation Guide

Follow these steps to install the Honeywell CC-PDIL51 correctly.

  1. Select the correct IOTA (CC-TDIL51 for non-redundant or CC-TDIL61 for redundant).

  2. Mount the IOTA in a 9-inch or 12-inch rack as required.

  3. Insert the CC-PDIL51 module into the IOTA until fully seated.

  4. Connect 24VDC field power between 18 and 30 volts.

  5. Wire each field device to the corresponding input channel.

  6. Verify ON condition with field resistance below 300 Ω at 15 VDC.

  7. Check LED indicators for proper channel status after power-up.


Package List

  • 1 x Honeywell CC-PDIL51 digital input module

  • 1 x IOTA connection guide label

  • 2 x Module retaining clips


Frequently Asked Questions (FAQ)

Q1: How many input channels does the CC-PDIL51 provide?
A1: The CC-PDIL51 provides 32 digital input channels. Each channel accepts 24VDC signals from field devices.

Q2: What is the galvanic isolation rating on the Honeywell CC-PDIL51?
A2: The Honeywell CC-PDIL51 has 1000 VAC RMS galvanic isolation. This applies to any input terminal voltage referenced to common.

Q3: Can I use this digital input module in a redundant configuration?
A3: Yes, the CC-PDIL51 supports optional redundancy. You must use the CC-TDIL61 IOTA model for redundant operation.

Q4: What happens if a field wire breaks on a connected device?
A4: The CC-PDIL51 includes NO open wire detection. The module diagnostics will identify the broken wire condition automatically.

Q5: What is the absolute delay time for an input signal on the CC-PDIL51?
A5: The absolute delay across the input filter and isolation is 5 ms ± 20%. This gives you a predictable response time between 4 ms and 6 ms.

About Ubest

Ubest Automation is a leading global provider of automation products, with deep partnerships with major automation manufacturers to provide customers with customized business solutions, cost-effective products, and comprehensive services.

 

Contact Us

Phone:+86 180 3000 5825

Address:Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China

Email: [email protected]

Contact: Klaus

 

Industry Links

© 2026, Ubest Automation Limited  All Rights Reserved. sitemap